Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  aerosol number concentration
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Continuous measurements of the aerosol particle number concentration (PNC) in the size range from 4.5 nm to 2 µm were performed at the Preila marine background site during 2008–2009. The concentration maxima in summer was twice the average (2650±50 cm-3). A trajectory-based approach was applied for source identification. Potential Source Contribution Function (PSCF) analysis was performed to estimate the possible contribution of long-range and local PNC transport to PNC concentrations recorded at the marine background site. The PSCF results showed that the marine boundary layer was not seriously affected by long-range transport, but that local transport of air pollution was recognized as an important factor. North Atlantic and Sea-Marine type clusters respectively represented 32.1% and 17.9% of the total PNC spectra and were characterized by the lowest PNCs (1080±1340 and 1210±1040 cm-3 respectively) among all clusters. Wavelet transformation analysis of 1-h aerosol PNC indicated that while the 16-h scale was a constant feature of aerosol PNC evolution in spring, the longer (∼60-h) scales appeared mainly over the whole year (except June). Principal component analysis (PCA) revealed a strong correlation between PNC and NaCl, highlighting the influence of sea-salt aerosols. In addition, PCA also showed that PNC depended on optical and meteorological parameters such as UVR and temperature.
EN
The indoor aerosols that are, among others, generated by air-conditioning systems are especially significant in school facilities. The measurements carried out in the new, air-conditioned auditorium have shown that the aerosol concentrations are strongly dependent on the operation of the air-conditioning system and the presence of students. The aerosol concentration was approximately 5 times higher when the air-conditioning (AC) system was switched on. An increased air movement inside the auditorium and the connected with it resuspention of the particles settled on the indoor surfaces could be responsible for this fact. It could also result from the ineffective operation of the AC filters. The presence of students in the auditorium caused an increase of the coarse aerosol particles irrespectively of the AC system operation. The results of aerosol particle monitoring should be taken into consideration while controlling the AC processes in order to ensure the desired indoor air quality in this type of facilities.
PL
Aerozole wewnątrz pomieszczeń generowane między innymi przez systemy klimatyzacyjne są szczególnie istotne w szkołach. Pomiary prowadzone w nowym, klimatyzowanym audytorium pokazały, że koncentracja aerozoli w bardzo dużym stopniu zależy od działania klimatyzacji i obecności studentów. Uzyskane wyniki pokazały, że w klimatyzowanej auli koncentracja aerozoli była około pięciokrotnie wyższa w porównaniu z sytuacją, gdy aula nie była klimatyzowana. Wynikać to może z faktu zwiększonej cyrkulacji powietrza i związanej z tym resuspensji cząstek aerozolowych osiadłych na powierzchniach wewnętrznych. Może to również wskazywać na nieefektywność działania systemu filtrującego powietrze. Obecność studentów w auli powodowała wzrost koncentracji grubych cząstek aerozolowych niezależnie od działania systemu klimatyzacyjnego. Dla zapewnienia pożądanej jakości powietrza wewnętrznego wyniki monitoringu cząstek aerozolowych powinny być brane pod uwagę przy sterowaniu procesami klimatyzacji w tego typu pomieszczeniach.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.