EN
Adsorption cooling and desalination technologies have recently received more attention. Adsorption chillers, using eco-friendly refrigerants, provide promising abilities for low-grade waste heat recovery and utilization, especially renewable and waste heat of the near ambient temperature. However, due to the low coefficient of performance (COP) and cooling capacity (CC) of the chillers, they have not been widely commercialized. Although operating in combined heating and cooling (HC) systems, adsorption chillers allow more efficient conversion and management of low-grade sources of thermal energy, their operation is still not sufficiently recognized, and the improvement of their performance is still a challenging task. The paper introduces an artificial intelligence (AI) approach for the optimization study of a two-bed adsorption chiller operating in an existing combined HC system, driven by low-temperature heat from cogeneration. Artificial neural networks are employed to develop a model that allows estimating the behavior of the chiller. Two crucial energy efficiency and performance indicators of the adsorption chiller, i.e., CC and the COP, are examined during the study for different operating sceneries and a wide range of operating conditions. Thus this work provides useful guidance for the operating conditions of the adsorption chiller integrated into the HC system. For the considered range of input parameters, the highest CC and COP are equal to 12.7 and 0.65 kW, respectively. The developed model, based on the neurocomputing approach, constitutes an easy-to-use and powerful optimization tool for the adsorption chiller operating in the complex HC system.
PL
W artykule przedstawiono jednowymiarowy model analityczny adsorpcyjnej pompy ciepła, porównując uzyskane wyniki przy zastosowaniu opisu równowagi adsorpcji równaniem Dubinina-Astachowa i równaniem równowagi Totha. Rozpatrywana jest jednostopniowa adsorpcyjna pompa ciepła silikażel – woda. Przyjęto, że adsorber zbudowany jest z rurek, na których osadzony jest adsorbent (silikażel). Opracowany model może posłużyć do określania charakteru pracy urządzenia oraz zmian temperatur, stężeń i strumieni ciepła w adsorberze/desorberze. Model został rozwiązany przy użyciu arkusza kalkulacyjnego. W obliczeniach prowadzonych z uwzględnieniem równania równowagi Totha zaobserwowano wyższe współczynniki SHP i SCP oraz wzrost ilości ciepła dostarczonego/ odprowadzonego do adsorbera, co wpłynęło na wzrost współczynników COP.
EN
In the presented paper the adsorber analytical modeling results based on Dubinin-Astakhov adsorption equilibrium and Toth adsorption equilibrium of water vapour on silica gel were compared. The adsorption heat pump with silica gel adsorbent and water adsorbate was discussed. A conventional single stage cycle adsorption heat pump is modeled. The design of the adsorber/desorber considered element is the tube with deposited silica gel bed. The analytical model was created to describe the temperature and concentration changes in the adsorber/desorber and consequently to describe the performance of the adsorption heat pump. The mathematical model was solved using common spreadsheet. A considerable increase in the calculated SHP and SCP in the model based on the Toth equilibrium equation as well as slight increase in the heat supplied or released from adsorbent influenced the increase in the COP.
PL
W artykule przedstawiono matematyczny model adsorpcyjnej pompy ciepła z adsorbentem silikażelem i adsorbatem wodą. Opracowano model analityczny pracy adsorbera/desorbera jednostopniowej dwukomorowej adsorpcyjnej pompy ciepła w celu określenia współczynnika efektywności COP tego urządzenia. Opracowany model może posłużyć do określania charakteru pracy urządzenia oraz zmian temperatur, stężeń i strumieni ciepła w adsorberze/desorberze. Następnie przeprowadzono analizę wpływu parametrów na pracę adsorbera/desorbera. Wyniki analizy przedstawiono na wykresach.
EN
Mathematical model of adsorption heat pump with silica gel adsorbent and water adsorbate is discussed. The authors focus on conventional single stage cycle adsorption heat pump operation with one adsorption/desorption heat exchanger to calculate coefficient of performance COP. The mathematical model was created to derive the performance of the heat pump and to describe the temperature, heat and uptake changes in the adsorber/desorber. An analysis of the impact of assessment parameters on operation of adsorption heat pump was performed. The calculation results from the analysis were presented in figures.