Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  adsorpcja białek
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Due to a lack of organs, cardiac support systems are being implanted in patients with severe congestive heart failure. One of the solutions to overcome complications such as infow obstruction or pump thrombosis, which may occur in the case of ventricular assist devices, is to modify the surface of cannulas for the controlled blood clotting process. The results obtained up till now for developed surface coatings clearly show the influence of topographical and mechanical parameters of the coatings on cell viability and protein adsorption mechanism. The new coatings should enable the controlled growth of scar tissue, resulting in the limitation of thromboembolic events, and the reduction of cystic tissue growth into the fow lumen. The aim of this study is to evaluate the correlation between surface topography parameters on the susceptibility of cells to grow and adhere to the substrate as a solution with potential for use in MCS (mechanical circulatory support) devices. Research on surfaces used in MCS devices and on inflow cannulas has been carried out for many years, while the novelty of the present solution makes it a milestone within that type of application simultaneously allowing for appropriate selection of process parameters. Surface modifcation of titanium alloy Ti6Al7Nb was carried out using vacuum powder sintering of CP-Ti (commercially pure titanium) powder with two morphologies (regular spheres and irregular grains). The characterization of coatings obtained with the proposed method and the influence of measured topographic parameters (applying scanning electron microscopy, contact angle measurement and contact proflometry) on the cytotoxicity and susceptibility to protein adsorption were presented. Advanced albumin adsorption studies have fully confrmed the dependence of surface complexity on protein adsorption. The obtained results show a high potential of the produced coatings toward enabling permanent integration at the implant with the soft tissue.
PL
Przedstawiono wyniki analizy adsorpcji białek zawartych w przemysłowym celulolitycznym preparacie enzymatycznym na poddanej obróbce wstępnej biomasie słomy kukurydzianej. Słoma kukurydziana i wyizolowana z niej lignina zostały użyte jako substraty w procesie enzymatycznego uwalniania cukrów prostych. Obróbkę wstępną biomasy prowadzono w środowisku alkalicznego 2-proc. roztworu H₂O₂ (pH 11,5). Wyznaczono wydajność hydrolizy glukanów (uzyskano 80,5%) i ksylanów (88,2%), stanowiących frakcje wstępnie obrobionej biomasy. Wyniki badań adsorpcji białek enzymatycznych na cząstkach surowca oraz ligninie opisano modelami izotermy Langmuira. Na podstawie tego modelu wyznaczono izotermy adsorpcji enzymów na polisacharydach zawartych w biomasie surowca.
EN
Corn straw biomass was pretreated with H₂O2₂ in alk. medium and then hydrolyzed in presence of a com. enzyme formulation at 50°C to produce glucose and xylose (yields 80.5% and 88.2%, resp.). The adsorption of enzymes on the raw material was described with Langmuir model isotherms.
3
Content available remote Antifouling surfaces in medical application
EN
The uncontrolled adhesion of biological compounds on the surface of implant materials is a harmful phenomenon that causes the function of medical devices to deteriorate. The design of surfaces that resist nonspecific protein, cell or bacteria adsorption (so-called antifouling surfaces) is of special interest as it is critical for the development of medical devices that have contact with physiological fluids. Significant efforts have been made in coating surfaces with bioinert macromolecules. Both self-assembled monolayers (SAM) and polymer brushes have attracted considerable attention due to their facile synthesis, their diverse physicochemical properties (composition, molar mass or topology) and their tunable surface chemistry (film thickness, grafting density, conformation and flexibility). In this article, a general description of surfaces with nonfouling properties is provided. Two basic classes of nonfouling polymers (hydrophilic and zwitterionic) are discussed with a series of practical examples.
PL
Artykuł stanowi przegląd literaturowy dotyczący powierzchni przeciwdziałających osadzaniu się związków biologicznie aktywnych. Niekontrolowana adhezja związków biologicznie aktywnych na powierzchni implantów to niekorzystne zjawisko pogarszające prawidłowe funkcjonowanie wszczepialnych urządzeń medycznych. Kluczowa więc jest możliwość utworzenia powierzchni odpornych na adhezję białek, komórek bądź bakterii (tzw. powierzchni przeciwdziałających osadzaniu się związków biologicznie aktywnych). W ostatnich latach dużym zainteresowaniem cieszą się powierzchnie zdolne do przeciwdziałania adsorpcji, pokryte powłoką wytworzoną na bazie biokompatybilnych i nietoksycznych polimerów. Najwięcej uwagi poświęcono samoorganizującym się warstwom (SAM) i powierzchniom ze szczepionymi łańcuchami polimerowymi. Zainteresowanie to wynika ze stosunkowo łatwej syntezy powierzchni, różnorodności fizykochemicznych właściwości stosowanych polimerów (skład, masa molowa i topologia) oraz samej powierzchni polimeru (grubość warstwy, gęstość szczepienia, konformacja łańcuchów). Omówiono dwie podstawowe klasy polimerów przeciwdziałających adhezji białek — hydrofilowe polimery oraz polimery zawierające jony obojnacze.
PL
Adsorpcja i odkładanie się białek osoczowych na sztucznych powierzchniach implantów medycznych, wspomaga proces adhezji komórek. Zjawisko to stanowi poważny problem w implantologii. Użycie biosensorów SPR, pracujących w systemie BiaCore, umożliwia badania odkładania się białek na powierzchniach tytanu i na warstwach NCD (nanocrystalline diamond), w realnym czasie trwania procesu. Pokazano, że sensory pokryte bardzo cienkimi warstwami (poniżej 30 nm), zarówno tytanu jak i NCD, charakteryzują się czułością porównywalną do czułości sensora kontrolnego.
EN
Adsorption and deposition of plasma proteins at artificial surfaces of medical implants promote celi adhesion process. SPR-biosensors, working in the BiaCore system, enable studies in a real time of the phenomenon of protein deposition onto surfaces of titanium and NCD (nanocrystalline diamond). It was shown, that sensors covered with very thin layers (less then 30 nm) of both, titanium and NCD, exhibit similar sensitivity as a control gold-surface sensor.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.