Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  active power measurement
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Frequency of a pulse signal at the test output of a static electricity meter is proportional to the active power of a connected load. When the consumed power changes, time between adjacent pulses of the test signal changes too, which prevents from obtaining the results of power measurement at regular time intervals. This work presents an algorithm for digital processing of a pulse frequency signal from the test output of a static electricity meter in order to obtain instantaneous values of active power at regular time intervals.
PL
Częstotliwość sygnału na wyjściu testowym statycznego licznika energii elektrycznej jest proporcjonalna do mocy czynnej dołączonego obciążenia. Gdy ta moc zmienia się, czas pomiędzy kolejnymi impulsami sygnału testowego również się zmienia, co uniemożliwia uzyskanie wyników pomiarów mocy w regularnych odstępach czasu. W pracy prezentuje się algorytm cyfrowego przetwarzania sygnału częstotliwościowego z wyjścia testowego licznika energii elektrycznej w celu uzyskania wartości chwilowych mocy czynnej w regularnych odstępach czasu.
2
Content available remote Cewka Rogowskiego w układzie pomiarowym mocy czynnej w obwodach nieliniowych
PL
W artykule przedstawiono koncepcję analogowego układu pomiarowego mocy czynnej w obwodach o niesinusoidalnych przebiegach napięć i prądów. Wyeliminowanie przekładników prądowych i zastosowanie cewki Rogowskiego do monitorowania prądów odkształconych pozwala na znaczne zwiększenie dokładności pomiarów. Przedstawiono analizę teoretyczną proponowanego układu pomiarowego.
EN
The paper presents an idea of an analog measuring circuit in the process of active power measurements if the current and voltage signals are non-sinusoidal. Elimination of the traditional current transformers which are being replaced by the Rogowski coils makes possible to increase accuracy of measurements. The theoretical analysis of the suggested circuit has been presented.
PL
W artykule przedstawiono krótką biografię urodzonego w pierwszej połowie XIX wieku w Wielkopolsce Hermanna Arona. Jego nazwisko kojarzone jest przede wszystkim ze znanym układem do pomiaru mocy czynnej i biernej w obwodach trójfazowych, realizowanym za pomocą dwóch watomierzy. Godna uwagi jest nie tylko jego kariera naukowa, ale również działalność przemysłowa, w której z niewielkiego warsztatu wyrosło w krótkim czasie uznane międzynarodowe przedsiębiorstwo Aron-Werke. To w tej fabryce powstawały pierwsze opatentowane przez Arona liczniki energii elektrycznej.
EN
A short biography of Hermann Aron, born in Polish Province Wielkopolska in the first half of the 19th century, has been presented in the paper. His surname is associated first of all with the well-known system used for measuring both active and reactive powers in three-phase circuits by means of two wattmeters. Not only his scientific career is notable but also his industrial activity. Aron-Werke, a company of international renown, came into existence from a small workshop in a short period of time. The first electricity meters, patented by Aron, came into being precisely in this factory.
4
Content available remote Active power measurement with a system based on DSP and analog multiplexer
EN
Measurements of the active power in power networks frequently serves for the identification of network parameters as well as those of power consumers. Requirements as to power measurements system have to respect the disturbances of the voltage and current signals and the necessity of their identification. The paper presents the method of the power measurement based on digital processing of the voltage and current signals. The proposed solution bases on the use of a single A/D converter with an analog multiplexer together with digital filters for time delay compensation between the sampled signals. Next the integral based on the Gregori's formula is calculated. Finally, the more correct evaluation of the time interval gives more precise power measurement result. The suggested solution gives the opportunity for development of a real time measurement system. In order to determine the correctness of the proposed method, some tests have been performed. The obtained results have confirmed the correctness of the accepted solutions and algorithms. The measurement error is less than 0.5% of the measurement range at the sampling frequency of 1KHz for a channel with a 12-bit A/D converter. The measurement time equal to 20 ms has been taken with respect to the network basic frequency.
PL
Pomiar mocy czynnej w sieci elektroenergetycznej jest często stosowany do identyfikacji jej parametrów oraz parametrów odbiorców. Wymagania stawiane pomiarowi mocy są związane z występującymi zaburzeniami w sygnałach napięć i prądów oraz koniecznością rozpoznawania wielkości tych zaburzeń. Artykuł przedstawia sposób pomiaru mocy oparty na cyfrowym przetwarzaniu sygnałów napięcia i prądu. Prezentowany sposób zakłada użycie jednokanałowego przetwornika A/C i multipleksera analogowego. Dla otrzymania synchronizacji czasowej próbek napięcia i prądu zaproponowano naprzemienne próbkowanie sygnałów napięcia i prądu, a następnie ich cyfrową filtrację. Filtry o skończonej odpowiedzi impulsowej różnią się rzędem o 1 i wprowadzają różne opóźnienia kompensujące naprzemienne próbkowanie Do obliczenia całki wykorzystano wzór Gregoriego oraz wprowadzono poprawkę związaną z przedziałem czasu, dla którego jest wyznaczana moc czynna. Przedstawiony sposób umożliwia zbudowanie stosunkowo prostego systemu pomiarowego pracującego w czasie rzeczywistym. W celu określenia poprawności przedstawionego sposobu pomiaru mocy czynnej przeprowadzono badania modelowe i eksperymentalne systemu pomiarowego opartego na przedstawionych zależnościach i algorytmie. Uzyskane wyniki potwierdziły poprawność zastosowanego sposobu pomiaru i pozwoliły oszacować błąd pomiaru na mniejszy od 0.5% zakresu pomiarowego dla częstotliwości próbkowania 1 kHz na kanał, za pomocą przetwornika A/C o rozdzielczości 12 bitów. Czas pomiaru był związany z częstotliwością podstawową sieci i umożliwił rozpoznawanie zaburzeń o porównywalnym czasie trwania. Zwiększenie częstotliwości próbkowania sygnałów napięcia i prądu pozwala na pomiar mocy czynnej dla szerszego przedziału częstotliwości. Wystarczy tylko 10 próbek na okres najwyższej składowej widma sygnałów napięcia i prądu, aby otrzymany 0.5% błąd pomiaru nie został przekroczony.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.