W pracy przedstawiono wyniki badania strat mocy w układzie kompensatora mocy biernej zbudowanego z baterii kondensatorów i dławików ochronnych. Zaprezentowane wyniki poddano analizie pod kątem możliwości zabudowania kompensatora w przeciwwybuchowej obudowie ognioszczelnej do zastosowania w sieci niskiego napięcia wyrobisk kopalni z zagrożeniem wybuchu metanu i pyłu węglowego.
EN
The results of power losses in the reactive power compensator built of capacitor banks and protective chokes have been presented in the paper. The showed results were analyzed for the possibility of installing the compensator in a flameproof explosion-proof enclosure for use in the low-voltage network of mine headings with the risk of methane and coal dust explosion.
2
Content available remote Active power losses in three-phase cable power lines
EN
This paper deals with the power quality in a distribution grid. It is aimed to analyze active power losses that arises in the distribution grid of 22 kV. The active power losses are influenced by various adverse effects such as the load voltage unbalance, the load power factor, and the higher harmonics. The influence of these adverse effects was analyzed by the simulation model that was created in the simulation program Matlab – Simulink. The simulation was performed for three types of power line cable conductors, their different lengths, different types of active power consumption and different values of adverse effects that are mentioned above. Pursuant to data, obtained from the real measurement on an existing part of the distribution grid, another simulation was performed. Based on the individual analyzes of the real measurement, the financial losses during a certain period were calculated.
PL
W artykule analizowano straty mocy czynnej w sieci rozdzielczej 22 kV. Analizowano nierównowagę napięć obciążenia, współczynnik mocy I obecność harmonicznych. Przeprowadzono symulację dla trzech typów linii kablowych o różnej długości I różnych poborów mocy. Inalizowano też koszty.
EN
Increasing emission standards and European Union policy require investment in the renewable energy sector. An increasing amount of renewable energy sources, including wind farms, requires changes in the power system in countries whose energy is based on large system power plants, mostly coal-fired. Stricter share of renewable energy sources in energy mix, may improve the country’s security and ensure the diversification of fuels and the gradual independence of conventional fuels. Thanks to regulation possibilities of doubly-fed induction generators, which are equipped with a significant part of wind turbines, it is possible to obtain better electricity parameters. The location of energy sources near the receiving nodes has a positive effect on the active power losses in the power system. This article analyzes the impact of a 30 MW wind farm on the level of active power losses in the power system, taking into account the different power factor values with which the wind farm can work. Simulation were carried out using the Powerworld Simulation software.
PL
Dynamiczny rozwój inteligentnych sieci elektroenergetycznych umożliwia wykorzystanie sterowalnych łączników do zmiany konfiguracji sieci rozdzielczej SN. W artykule omówiono wpływ rekonfiguracji systemu dystrybucyjnego SN na wartość strat mocy czynnej z uwzględnieniem dobowej zmienności obciążenia. Bazując na zmodyfikowanym przez autora 33-węzłowym testowym systemie dystrybucyjnym IEEE przedstawiono problem doboru odpowiedniej czułości algorytmu oraz zaproponowano metodykę wyboru konfiguracji pracy sieci rozdzielczej SN w cyklu dobowym. Jako funkcję celu zastosowano kryterium minimalizacji strat mocy czynnej. Badania przeprowadzono w programie rozpływowym DIgSILENT Powerfactory dla dwóch wariantów krzywych obciążenia i dla różnych wartości współczynnika czułości. Wyniki obliczeń dowodzą, że zapewnienie odpowiedniej konfiguracji pracy sieci dystrybucyjnej SN umożliwia zmniejszenie strat mocy czynnej.
EN
The dynamic development of smart grids allows the use of remote controllable switches to change the configuration of the MV distribution network. The article discusses the impact of distribution system reconfiguration on active power losses, taking into account the typical daily load profiles. Based on modified IEEE 33-bus test distribution system the article presents the method of selection the appropriate sensitivity coefficient and the configuration of the MV network. The objective function is to minimize active power losses. Studies were performed in DIgSILENT Powerfactory application for two variants of the daily load curve and for different values of sensitivity coefficient. The calculation results indicate, that ensuring adequate working configuration of MV distribution network, helps to reduce active power losses.
PL
W artykule przedstawiono zastosowanie algorytmu rojowego PSO do optymalizacji nastaw grupy przesuwników fazowych w systemie elektroenergetycznym. Jako kryterium optymalizacji zastosowano minimalizację strat mocy czynnej w sieci testowej IEEE 118. Przeanalizowano wpływ maksymalnej dozwolonej prędkości cząstek na efektywność algorytmu optymalizacji. Wyniki badań pokazują ważność tego parametru.
EN
In response to the growing problem of unscheduled flows, a larger and larger number of transmission system operators in Europe equip their systems with phase shifting transformers (PSTs). PSTs are special transformers which installed in a transmission line enable regulation of the voltage phase angle and thereby change of the active power flow in the line. However, the use of several PSTs installed geographically close to each other must be coordinated in order to efficiently use those devices and avoid their adverse interactions. The coordination of a group of such devices leads to a multidimensional optimization problem. In this paper, the coordination problem was solved by optimization of settings of all analyzed PSTs, based on the swarm algorithm. This approach was examined and tested on an IEEE 118-bus test system. The minimization of active power losses in this system was used as the optimization criterion. The impact of maximum allowed velocity of particles on the effectiveness of the optimization algorithm was analyzed. The result shows that the improved effectiveness of the proposed approach can be obtained by careful selection of this parameter.
6
PL
Użycie kilku przesuwników fazowych w połączonym systemie elektroenergetycznym musi być skoordynowane w celu efektywnego wykorzystania istniejącej infrastruktury sieciowej, ale również do uniknięcia niepożądanych interakcji tych urządzeń i zapewnienia bezpieczeństwa pracy sieci. W artykule przedstawiono metodę wyznaczania optymalnych (skoordynowanych) nastaw przesuwników fazowych, opartą na algorytmie optymalizacji rojem cząstek (PSO). Jako kryterium optymalizacji zastosowano minimalizację strat mocy czynnej. Pokazano wyniki obliczeń dla sieci testowej zawierającej 118 węzłów.
EN
The use of several phase shifters in an interconnected power system must be coordinated in order to efficiently use the existing grid infrastructure as well as to avoid adverse interactions of theses devises and guarantee the secure operation of the system. This paper presents a method for determining the optimal (coordinated) settings of phase shifters based on the particle swarm optimization (PSO) algorithm. The goal of optimization was to minimize the active power losses. Simulation results for an IEEE 118-bus test system are given.
EN
The addition of a new source of active power to an electric power distribution network alters its operation conditions. The effect of such changes depends on the power of the additional source, its location in the network as well as its type. In the paper the influence of the active power source on the selected parameters of the operations of the distribution network – such as the active power losses and voltage levels – is presented. Also, the influence of the level of power of the additional source and the level of the network’s load on the location of tie points is considered.
PL
Instalacja dodatkowego źródła mocy czynnej w elektroenergetycznej sieci rozdzielczej zmienia warunki jej pracy. Efekt zmian zależy od mocy dodatkowego źródła, miejsca jego lokalizacji w sieci oraz rodzaju przyłączanego źródła. W pracy analizuje się wpływ źródła mocy czynnej na wybrane parametry pracy sieci dystrybucyjnej takie jak straty mocy czynnej i poziomy napięć. Dokonano analizy wpływu mocy przyłączanego źródła i poziomu obciążenia sieci na lokalizację stałych punktów podziału sieci.
EN
Distributed generations (DGs) are continuously integrated into the distribution systems either by the utilities or the customers. Site and size of DGs have significant impacts on the system power losses . In this paper, the most recent and practical PSO algorithms are used to optimally allocate DGs in radial distribution systems, and the obtained results are discussed and compared to each other. The single objective is to minimize network power losses using the least possible injected power from DGs. To have a good benchmark for comparisons of different PSO Techniques, simulations carried out on IEEE 33-bus and 69-bus standard radial distribution systems.
PL
Rozproszone układy generacji DGs mogą być dołączane do system energetycznego albo przez wytwórcę albo użytkownika. W artykule przedstawiono algorytm PSO umożliwiający optymalizację dołączenia system DGs do sieci radialnej. Głównym celem optymalizacji jest zmniejszenie strat mocy.
EN
Reactive Power compensation is the one of the basic methods of improvement of power network operating conditions. Application of this method contributes to transmission capacity improvement of active power. Correctly applied compensation of reactive power leads to improvement of voltage conditions in the power network and reduction of power losses transmission. Following paper describes the effectiveness of reactive power compensation as its influence on the transmission power losses level in distribution network depending on control strategy. The influence of control strategy choice on effectiveness of reactive power compensation in distribution network.
PL
Kompensacja mocy biernej to jedna z podstawowych metod poprawy warunków pracy sieci elektroenergetycznej. Zastosowanie tej metody przyczynia się do zwiększenia zdolności przesyłu mocy czynnej. Prawidłowo stosowana kompensacja mocy biernej skutkuje poprawą warunków napięciowych w sieci elektroenergetycznej a także zmniejszeniem przesyłowych strat mocy czynnej. W artykule przedstawiono wszechstronną analizę skuteczności kompensacji mocy biernej pod kątem strat mocy w sieci dystrybucyjnej, w zależności od przyjętego kryterium sterowania.