Content available remote Modelling of wastewater treatment plant operation under variable conditions
EN
Modelling of the wastewater treatment plant in Żory, Poland was carried out using the BioWin 2.1 simulation program based on the real data regarding acquired in 2016-2017. It was made the static and dynamic calibration of the developed model of the treatment plant. The calibration and verification procedure was performed. In order to determine the optimal working conditions for the WWTP Żory, a series of simulation tests were carried out (44 simulations of the WWTP Żory model work). The simulations were carried out for: variable wastewater temperature, uniform and uneven distribution of wastewater to individual biological sequences, at variable sludge age and rate of the internal recirculation, and variable oxygen concentration in the nitrification and denitrification tanks. It was also investigated the influence of the external carbon source dosing, and the management method of wastewaters recycled from dewatering system, on the effectiveness of nitrogen removal in simulation conditions. The simulation studies resulted in determination of the optimal parameters for the WWTP Żory work, considering the variable inflow parameters, in order to intensify removal of the nitrogen compounds by biological means, and to achieve the target concentration of the total nitrogen at the outlet, i.e. 10 mgN/L.
PL
Modelowanie oczyszczalni ścieków w Żorach prowadzono z wykorzystaniem programu symulacyjnego BioWin 2.1 w oparciu o dane rzeczywiste pozyskane w latach 2016-2017. Dokonano kalibracji statycznej i dynamicznej opracowanego modelu oczyszczalni. Przeprowadzono procedurę kalibracyjną i weryfikacyjną. W celu określenia optymalnych warunków pracy dla OS Żory wykonano szereg badań symulacyjnych (44 symulacje pracy modelowej OS Żory). Symulacje prowadzono dla: zmiennej temperatury ścieków, równomiernego i nierównomiernego rozdziału ścieków do poszczególnych ciągów biologicznych, przy zmiennym wieku osadu czynnego, stopniu recyrkulacji wewnętrznej i stężeniu tlenu w komorze tlenowej i denitryfikacji. Zbadano także wpływ dozowania zewnętrznego źródła węgla i sposobu gospodarowania wodami nadosadowymi na efektywność usuwania azotu w warunkach symulacyjnych. Efektem przeprowadzonych badań symulacyjnych było wyznaczenie optymalnych parametrów pracy OS Żory z uwzględnieniem zmiennych parametrów dopływu, w celu intensyfikacji usuwania związków azotu na drodze biologicznej i osiągnięciu docelowego stężenia azotu ogólnego na odpływie, tj. rzędu 10 mgN/L.
EN
This paper investigates the use of Adaptive Generalized Predictive Control (TS-AGPC) for an activated sludge reactor, based on a Takagi Sugeno (TS) model, and presents the comparison between the latter and Generalized Predictive Control using an overall TS model (TS-GPC). The reduced bio-reactor Activated Sludge ASM1 Model, which describes the biological degradation of an activated sludge reactor, is designed based on several simplifications, as a TS model, its structure being based on a set of linear submodels, covering the process input-output space, interpolated by a nonlinear weighting function µ. The adaptive GPC approach is obtained by switching between linear submodels of the TS formulation. This is performed by selecting, in turns, a portion of the weighting function µ. The winning model will then act as an internal model for the TS-AGPC control law formulation, whereas the complete TS model is used in the calculation of the TS-GPC control law. Finally, the performance under input and parametric disturbances as well as control variable constraints of the TS-AGPC controller are compared to those for a global TS-GPC controller and a benchmark PID in terms of error and response dynamics.
PL
W artykule przedstawiono sposób wykonania kalibracji biokinetycznego modelu osadu czynnego przy użyciu programu komputerowego BioWin. Schemat komputerowy został opracowany na podstawie oczyszczalni ścieków pracującej w technologii sekwencyjno – przepływowej. Do kalibracji biokinetycznego modelu osadu czynnego wykorzystano wyniki badań ścieków dopływających i oczyszczonych pochodzących z istniejącego obiektu. Wynikiem przeprowadzonych analiz były zmiany w biokinetycznym modelu w zakresie parametrów kinetycznych oraz pracy urządzeń oczyszczalni. Przedstawiony sposób badania wpływu wybranych parametrów biokinetycznego modelu osadu czynnego (m.in. maksymalna szybkość wzrostu autotrofów, udział zawiesiny organicznej w zawiesinie ogólnej, skuteczność pracy osadników wtórnych) może być wykorzystany podczas prowadzenia badań symulacyjnych innych oczyszczalni ścieków.
EN
This paper presents a method for calibration of activated sludge model with the use of computer program BioWin. Computer scheme has been developed on the basis of waste water treatment plant operating in the sequential – flow technology. For calibration of the activated sludge model data of influent and treated effluent from the existing object were used. As a result of conducted analysis was a change in biokinetic model and kinetic parameters parameters of wastewater treatment facilities. The presented method of study of the selected parameters impact on the activated sludge biokinetic model (including autotrophs maximum growth rate, the share of organic slurry in suspension general operational, efficiency secondary settling tanks) can be used for conducting simulation studies of other treatment plants.