EN
Intensive economic development causes the risk of introducing the so-called emerging contaminants (EC) into the environment. This group of contaminants includes pharmaceuticals, including non-steroidal anti-inflammatory drugs (NSAIDs), the consumption of which is steadily increasing in Poland as well as worldwide. Such specific contaminants may also cause problems at the stage of biological treatment of wastewater, especially in individual systems that are sensitive to changes in wastewater composition. The study examined an onsite wastewater treatment system based on the activated sludge technology, to which three different pharmaceuticals were dosed in the quantities normally used in therapy. The operation of the biological reactor under these conditions was analysed by comparing contamination indicators at the inlet and outlet of the treatment plant at different doses of pharmaceuticals. It was found that the doses used did not significantly worsen the effects of wastewater treatment, except for paracetamol, which at a dose above 1000 mg/d caused a slight reduction in the efficiency of the facility. The dosed pharmaceuticals also did not deteriorate the sedimentation properties of the activated sludge. Although typical doses of pharmaceuticals do not interfere with the operation of the biological reactor, residual substances and their metabolites may be released into the environment; it is therefore reasonable to consider the introduction of an additional treatment stage to remove micropollutants from the wastewater.
EN
The representation of Peritricha ciliates was studied in the activated sludge of two wastewater treatment plants (WWTP), one of which operates using a technology that includes alternating aerobic, anoxic and anaerobic conditions in bioreactors (Lublin, Poland), and the other – only aerobic conditions (Sumy, Ukraine). During the study, 14 Peritricha species were identified in the WWTP Lublin, and 13 species were identified in the WWTP Sumy. The similarity of species lists was 81.5% (Sørensen index). On the basis of on the similarity and taking into account the occurrence rate (≥ 60%), a common group of Peritricha species characteristic of the activated sludge from these two types of treatment facilities was identified, which includes 4 species of colonial Peritricha: Carchesium polypinum, Epistylis coronata, Epistylis longicaudatum and Opercularia articulata, and also 4 species of solitary Peritricha: Vorticella aquadulcis, Vorticella convallaria, Vorticella infusionum and Vorticella microstoma. Despite the very high similarity in species composition, statistical analysis of the population structure of Peritricha showed a clear separation of two WWTPs with different wastewater treatment technologies. If there is a significant similarity in the species composition of Peritricha, the species, based on their abundance and occurrence, are divided into two groups, focused on different technological schemes. The population structure of Peritricha responds to the changes in purification technology, showing the changes not so much in species composition as in their quantitative structure. The differences in bioreactor conditions and increased effluent treatment efficiency demonstrated by the WWTP Lublin result in differences in Peritricha species structure, which are reflected in higher Peritricha abundance in WWTP Lublin compared to WWTP Sumy.
PL
Biologiczny proces osadu czynnego jest najpopularniejszą metodą stosowaną w licznych oczyszczalniach ścieków, która z reguły pozwala na uzyskanie wymaganego efektu ekologicznego. Jednakże charakteryzuje się ona również pewną niestabilnością uzyskiwanych efektów zależną od warunków i parametrów, na które częściowo eksploatator nie ma wpływu. Dlatego też poszukuje się szybkich technik analitycznych do kontroli i oceny osadu czynnego, które w przypadku pojawienia się nieprawidłowości w komorach biologicznych pozwolą na podjęcie decyzji operacyjnych korygujących proces, jak również jego optymalizację. W niniejszym artykule zaprezentowano możliwości wykorzystania analizy FTIR-DRIFT zawiesiny osadu czynnego połączonej z analizą chemometryczną wybranych parametrów osadu i ścieków do oceny procesu oczyszczania na poszczególnych etapach pracy reaktora biologicznego. Uzyskane wyniki wskazują, że zastosowanie techniki FTIR do szybkiej oceny procesu biologicznego jest możliwe, a w połączeniu z modelowaniem PLS i po odpowiednim skalibrowaniu z wartościami parametrów fizyczno-chemicznych może stanowić element kontrolny w eksploatacji oczyszczalni ścieków.
EN
The activated sludge process is the most popular method used in many sewage treatment plants, which usually allows to achieve the required ecological effect. However, it is also characterized by a certain instability of the obtained effects, depending on conditions and parameters which are partly beyond the operator's influence. Therefore, rapid analytical techniques are being sought for the control and assessment of activated sludge, which, in the event of irregularities occurring in biological tanks, will allow operational decisions to be made to correct the process as well as its optimization. This article presents the possibilities of using FTIR-DRIFT analysis of activated sludge suspension combined with chemometric analysis of selected sludge and sewage parameters to assess the course of the purification process at various stages of operation of the biological reactor. The obtained results indicate that the use of the FTIR technique for rapid assessment of a biological process is possible, and in combination with PLS modeling and after appropriate calibration with physical and chemical parameters, it can constitute a control element in the operation of sewage treatment plants.
EN
Rational use of water resources is one of the urgent problems for arid regions of Kazakhstan. The biocenosis of activated sludge of urban wastewater treatment plants in Zhanaozen periodically encounters stressful situations associated with violation of the operating mode of equipment or emergency discharges of toxicants into the wastewater treatment plant system. It has been established that with sharp fluctuations in the physicochemical parameters of aqueous solutions, protozoal organisms are primarily eliminated from the composition of activated sludge. This pattern was noted with an increase in the content of ammonium nitrogen, phosphorus, monoethanolamine and pH fluctuations in wastewater. Under the conditions of a 10-month period of active insolation in Western Kazakhstan, the species diversity of the algoflora of activated sludge correlates with the duration of daylight hours; it was found that diatoms predominate in the autumn-winter period of the year, whereas blue-green and green algae predominate in the spring-summer period.
EN
The purpose of the present study is to investigate the performance of an upgraded oxidation ditch (OD) system, which was designed and implemented to solve the problem of sludge accumulation at the bottom as well as to get the best removal efficiency of total nitrogen (TN). The upgrading concept is based on dividing the operating volume of the upgraded OD to achieve interchanging between aerobic and anoxic circumstances in order to provide simultaneous nitrification and denitrification (SND). The obtained results indicated that the average TN removal efficiency was 60%, which could be obtained due to a highly efficient SND approach. In addition, the better TN removal efficiency corresponds to the lower sludge volume index (SVI), which reflects the efficiency of the upgraded OD in preventing the accumulation of sludge at the bottom. Effluent ammonium-nitrogen (NH4+-N) and nitrate (NO3--N) concentrations corresponding to a minimum SVI of 41.9 mL/g were 8.6 mg/L for NH4+-N and 8.6 mg/L for NO3--N, respectively. Furthermore, the upgraded OD successfully removes 5-day biochemical oxygen demand (BOD5), chemical oxygen demand (COD), and total suspended solids (TSS) below the permissible limit for final effluent of 60, 80, and 50 mg/L respectively.
EN
Hospital wastewater is of a complex nature and is generally discharged into urban sewage systems. This study evaluated the removal efficiency of organic and biological contaminants from a hospital wastewater treatment plant using extended aeration activated sludge. The study was conducted at a treatment plant scale, with 14 hours of feed. The plant consists of a pre-filter, a collector and crumbler tank, a homogenization tank, two biological reactors of 80 000 liters capacity each, two settlers and a contact disinfection chamber. Three flow rates of 3 L/s, 4 L/s and 5 L/s were tested in each biological reactor, with application of three concentrations of residual chlorine with sodium hypochlorite to the effluent of the settling tanks (0.3 ppm, 0.4 ppm and 0.5 ppm). The removal efficiency of suspended solids varied according to flow rate. The reactor with a flow rate of 3 L/s and 0.5 ppm of residual chlorine achieved the highest removal of suspended solids (91.95%), biological oxygen demand (97.52%) and fecal coliforms (99.99%). Finally, the quality of the hospital wastewater is within the limits of the national and international environmental quality thresholds.
PL
Zaostrzające się wymogi, dotyczące jakości ścieków odprowadzanych do odbiornika, doprowadziły do opracowania wielu urządzeń wykorzystywanych podczas biologicznego oczyszczania. Obecne badania prowadzone w sektorze wodno-ściekowym skupiają się często na poszukiwaniu efektywnych energetycznie rozwiązań technicznych i technologicznych, wywierających jak najmniej negatywny wpływ na środowisko „przy jednoczesnym obniżeniu kosztów eksploatacyjnych. W systemach oczyszczania powszechnie wykorzystuje się właściwości struktur mikroorganizmów w postaci kłaczków osadu czynnego, które usuwają organiczne i biogenne związki zawarte w ściekach. Ważnym elementem powyższego rozwiązania jest zastosowanie układu mieszania i napowietrzania bioreaktorów w odpowiedniej konfiguracji. W oczyszczalni ścieków, z częścią biologiczną, działającej w technologii SBR, stosuje się wiele rodzajów urządzeń do mieszania. W niniejszym artykule przedstawiono zastosowanie innowacyjnego wolnoobrotowego systemu mieszania w sekwencyjnych bioreaktorach porcjowych, w których czynnikiem procesowym jest osad czynny.
EN
Increasing demands on the quality of wastewater discharged to the receiving water have led to the development of many biological treatment devices. Current research in the water and wastewater sector often focuses on finding energy-efficient solutions that have the least negative impact on the environment while reducing operating costs. In wastewater treatment systems, it is common to utilize the properties of microbial structures in the form of activated sludge flocs that remove organic compounds and biogenic contained in wastewater. An important part of the solution is the mixing and aeration system configuration used. In the treatment plant operating in the SBR technology, there are many types of mixing devices that are used in the process of wastewater treatment. This paper presents the application of an innovative slow-speed mixing system in sequential batch bioreactors in which activated sludge is a process factor.
PL
W artykule omówiono metody wykorzystywane w biodegradacji wielopierścieniowych węglowodorów aromatycznych występujących w osadach czynnych i dennych. Przeanalizowano ich skuteczność i wpływ na oczyszczanie środowiska z zanieczyszczeń WWA.
EN
The article discusses the methods used in the biodegradation of polycyclic aromatic hydrocarbons found in active and bottom sediments. Their effectiveness and influence on the purification of the environment from PAH pollution were analyzed.
PL
Oczyszczanie ścieków metodą osadu czynnego zastosowano po raz pierwszy na początku XX wieku. Od tego momentu, po wielu udoskonaleniach, metoda ta jest wykorzystywana, z powodzeniem, na całym świecie.
EN
The relationship between a quality of activated sludge microbiota and wastewater treatment plant (WWTP) operational stability has been defined in the past few decades. However, this dependence is not so clear in the case of industrial wastewater treatment. In this article, a very specific example of industrial textile wastewater treatment plant (ITWTP) is analyzed. Textile effluents are well known as highly contaminated wastewater containing many biodegradable compounds. Microscopic analysis included flocs morphology examination, attempts to evaluate the Sludge Biotic Index (SBI), and identification of dominant filamentous microorganisms. Routine operational control of ITWTP covered pH, temperature, redox potential, dissolved oxygen and COD measurements. The average ecosystem existing in the described ITWTP differed significantly compared to municipal WWTPs. The flocs were smaller and irregular. Filamentous bacteria did not cause foaming although filaments index reached 4. Nostocoida limicola I dominated with significant amounts of type 0041 and type 021N. The evaluation of SBI was impossible as the most of protozoan was in the form of cysts. The overall microbiota diversity correlated with COD removal in activated sludge unit of ITWTP.
EN
The paper deals with the problem of wastewater treatment with specific physicochemical composition (increased ammonium nitrogen concentration) which were generated in Motor Rest Areas (MRA). Conventional biological wastewater treatment systems with activated sludge were used to purify the wastewater from sanitary equipment used in MRA. On the basis of the research conducted on four MRA, an attempt was made to determine the impact of the wastewater quality on biological wastewater treatment processes. The wastewater supplied to the treatment system was characterized by predominance of biologically non-degradable organic matter (average BOD/ COD ratio 4.39 – 10.42) as well as high concentration of ammonium nitrogen 273.9 – 334.55 mgN-NH4/dm3. The wastewater alkalinity determined by high content of ammonium nitrogen had a negative impact on the biological treatment processes. Unequal pollution load and temporary, high hydraulic load caused leaching of solid suspension from settling tank as well as leaching of particles of activated sludge from the reactor’s chamber. The lack of organic matter susceptible to biological decomposition makes it difficult to develop the biocenosis of activated sludge, and the limits of ammonium nitrogen concentration inhibit the nitrification processes.
EN
In this study, the effect of bioaugmentation on the sequencing batch reactor (SBR) performance while treating municipal wastewater and reject water under various temperature conditions was examined. Two lab-scale SBRs, each with the active volume of 8 L were used to perform this research. For bioaugmentation, a mixture of wildliving Bacteria and Archaea in a dose 0.25 mL was added to SBR A, while SBR B was a control one. Both reactors were fed with a mixture of wastewater and 13% v/v reject water. During the experiment, 5 phases with different temperature range were distinguished, each one lasted 14 d. The temperatures were investigated in 5°C increments, i.e. 20, 25, 30, 25 and 20°C. The obtained results indicated that in the bioaugmented reactor (SBR A), lower concentrations of NH4+–N, TSS, NO2-–N in effluent were observed as compared to control (SBR B). While for NH4+–N, regardless the temperature, the observed differences were statistically significant. Importantly, in both SBRs, the process was carried out in a stable way.
EN
In order to use the purified wastewater for the irrigation of a golf course in the Taghazout area (Southwestern of Morocco), this study was conducted to evaluate the physicochemical and bacteriological quality of the treated wastewater in the new Aourir plant (Activated Sludge technology). In order to achieve these objectives, three types of water were analyzed: raw water (RW), biologically treated water (BTW) and water treated by ultraviolet radiation (UV-TW). The physicochemical parameters analyzed were Temperature, pH, Electrical Conductivity (EC), Dissolved Oxygen (DO), Chemical Oxygen Demand (COD), five-day Biological Oxygen Demand (BOD5), Total Suspended Solids (SS), Nitrate (NO3), and Orthophosphates (PO4). Otherwise, the analyzed biological parameters are Total Coliforms (TC), Fecal Coliforms (FC), Escherichia coli (E. coli), and Fecal Streptococci (FS). The physicochemical parameters showed that temperature is always lower than 30°C, the pH is close to neutrality and a strong fluctuation of the high electrical conductivity (2700 μS/cm) occurs in UV-TW. At all stages of wastewater treatment, COD, BOD5, SS, NO3 and PO4 were below the limit values recommended by Moroccan standards. The bacteriological results showed a high level of bacterial contamination in RW and BTW, but in UV-TW the loads did not exceed 3 log10. The average loads of TC, FC, E. coli and FC in UV-TW were 2.13, 1.67, 1.77, and 2 (log10 CFU/100ml) respectively. Activated sludge treatment combined with UV has demonstrated sufficient quality to reuse treated water in irrigation; however, the UV treatment requires control to avoid any effect on the microbiological and physicochemical quality of green spaces and groundwater.
PL
Zjawisko występowania piany i kożucha na powierzchni reaktorów biologicznych może być spowodowane przez obecność w osadzie czynnym promieniowców. Jak pokazują doświadczenia na wielu oczyszczalniach, zalecane standardowe metody, np. utrzymywanie niskiego stężenia osadu, mogą okazać się niewystarczające. Również najpowszechniej stosowana w tym celu aplikacja jonów glinu może być nieskuteczna, ponieważ dekontaminacja bakterii następuje tylko w osadzie czynnym. Zabieg ten nie ma już realnego wpływu na komórki nagromadzone w kożuchu. Przy zastosowaniu innych metod, jak np. środki antypienne, efekt jest tylko chwilowy, a towarzyszący dozowaniu tych produktów spadek tlenu niekorzystnie wpływa na aktywność biocenozy osadu czynnego.
PL
Typ 021N jest jednym z najczęściej występujących bakterii nitkowatych wywołujących pęcznienie osadu czynnego w Europie [ Jenkins i in. 2004; Martins i in. 2004]. Mimo to informacji o jego preferencjach środowiskowych jest niewiele. Jednym z powodów jest fakt, że w obrębie typu 021N występują różne szczepy [ Martins i in. 2004; Nielsen i in. 1998]. Aby je rozróżnić konieczna jest analiza sekwencji rybosomalnego RNA. Znane są również doniesienia związane z odmienną przeżywalnością omawianego typu, po zastosowaniu różnych środków chemicznych.
PL
Proces konwencjonalnego osadu czynnego jest od ponad 100 lat podstawową metodą stosowaną w oczyszczaniu ścieków komunalnych. Polega on na utlenianiu biologicznym, w trakcie którego materia organiczna jest przekształcana w biomasę i dwutlenek węgla. Jednak proces konwencjonalnego osadu czynnego stoi przed palącymi wyzwaniami związanymi z wysokim zużyciem energii, koniecznością zagospodarowania osadu nadmiernego itp. Obecnie prawie wszystkie oczyszczalnie ścieków z konwencjonalnym osadem czynnym jako głównym procesem są eksploatowane w sposób energochłonny.
PL
W wyniku ciągle postępujących prośrodowiskowych zmian prawnych eksploatatorzy stają przed koniecznością uzyskiwania wysokich redukcji zanieczyszczeń, niekiedy dalszej poprawy parametrów ścieku oczyszczonego, zwłaszcza substancji biogennych. Niestety, w branży odnotowuje się tendencję wzrostową dla niezidentyfikowanych zrzutów ścieków, które w sposób często niekontrolowany mogą powodować natychmiastowe wystąpienie problemów technologicznych na oczyszczalni. Dodatkowo w ostatnich latach możni zaobserwować zwiększoną ilość dopływów o ładunku charakterystycznym dla ścieków przemysłowych, aniżeli bytowych. Bardzo często są to ścieki bogate w substancje tłuszczowe oraz środki powierzchniowo czynne, które w stosunkowo szybkim czasie mogą przyczynić się do rozwoju w osadzie czynnym bakterii promieniowców. To z kolei może powodować znaczne pogorszenie sedymentacji osadu oraz wystąpienie piany i kożucha na powierzchni reaktorów biologicznych W momencie, gdy najpowszechniej stosowane środki okazują się nieskuteczne należałoby rozważyć zmianę strategii ograniczenia promieniowców oraz skutków ich występowania. Jak szybko oraz efektywnie poradzić sobie z tym problemem opisano szerzej w artykułach autorstwa M. Bazeli, Forum Eksploatatora nr 1/2020 oraz M. Bazeli, M. Sielska, Forum Eksploatatora nr 1/2021.
PL
Reaktory z przepływem nieciągłym, nazywane SBR, to takie reaktory, do których ścieki surowe dopływają w sposób ciągły, a odpływają do odbiornik okresowo, najczęściej jeden lub dwa razy na dobę. Klasyczny reaktor SBR to zbiornik wyposażony w układy napowietrzania, mieszania i pomiarowe, np. poziomu i stężenia tlenu. Reaktor SBR jest jednocześnie reaktorem i osadnikiem wtórnym. Osad czynny w takim reaktorze poddawany jest stałemu obciążeniu, co jest jedną z najważniejszych przyczyn niekorzystnego zjawiska tzw. puchnięcia osadu wywołanego nadmiernym rozwojem bakterii nitkowatych.
EN
A new method for measurement of sludge blanket height (SBH) based on image analysis is presented. The proposed method uses a histogram back-projection algorithm to distinguish between the settling sludge and supernatant and can be used with sludge possessing different coloring characteristics both in the sludge color and the color of supernatant produced. Individual pixels in the acquired image are compared with a histogram of a representative sludge region. Therefore, the proposed method relies neither on the assumed shape of light intensity profile nor on the dominant sludge or supernatant color. Batch sedimentation tests are presented for different initial sludge concentrations and different background colors to simulate different sludge characteristics. Parameters of a settling velocity function are estimated based on the obtained results. Additionally, an algorithm is proposed that enables the zone settling velocity (ZSV) to be estimated before the batch sedimentation test is completed.