This paper is a review on the part of the failure analysis in the semiconductor region, especially in the integrated circuit (IC) design. Initially, the literature review depends on the keyword of acoustic-microscopy. Then, it followed by the example on the scanning acoustic-microscope (SAM), confocal scanning acoustic-microscope (CSAM), and C-mode scanning acoustic-microscope (C-SAM) technique. These three SAM techniques are used in various situation and have a different effect on the sample. Previous works on SAM, C-SAM and CSAM related technologies are reviewed by many researchers in this paper.
PL
W artykule przedstawiono przegląd analizy defektów układów półprzewodnikowych (obwodów scalonych) z wykorzystaniem mikroskopów akustycznych. Zaprezentowano mikroskop akustyczny SAM, mikroskop skaningowy CSAM i mikroskop typu C C-SAM. Każda z tych metod pozwala na różnego typu badania.
EN
There is an increasing interest in casting pressure elements in the automotive and household industry. Mechanical properties, implementation precision and quality play major role here. Unfortunately, this manufacturing technology is accompanied with disadvantageous features of the material structure as porosity, which must be controlled during production. On the basis of comparative studies of three selected research methods the most optimal research method for this group of products and materials was selected. It is a technique based on acoustic microscopy which, allows for the research of large components in the X and Y axes and a relatively high Z-axis. The research enables an analysis of all components without necessity of cutting a product into smaller elements subjected to separate analysis.
EN
The article presents the possibilities of using acoustic microscopy to evaluate defects in resistance spot welding joints. For this purpose, the welded joints were made from two grades of aluminium plates EN AW5754 H24 and EN AW6005 T606, which were then subjected to non-destructive testing using acoustic microscopy and conventional destructive testing using traditional light microscopy techniques. Additionally, the study examined the influence of the typical contaminants found in industrial conditions on the quality of the joint.
PL
W artykule przedstawiono możliwości wykorzystania mikroskopii akustycznej do oceny niezgodności połączeń zgrzewanych. W ramach prac badawczych wykonano połączenia zgrzewane dwóch gatunków blach aluminowych EN AW5754 H24 oraz EN AW6005 T606, które następnie zostały poddane badaniom nieniszczącym z wykorzystaniem mikroskopii akustycznej oraz konwencjonalnym badaniom niszczącym z wykorzystaniem tradycyjnych technik przy użyciu mikroskopii świetlnej.
EN
The article presents the possibilities of using of acoustic microscopy to evaluate of defects of spot welded joints. For this purpose, the spot welded joints were made from two grades of alumina plates EN AW5754 H24 and EN AW6005 T606, which were then subjected to non-destructive testing using acoustic microscopy and conventional destructive macroscopy. Additionally, it was examined the influence of the typical contaminants found in industrial conditions for the quality of the joint.
5
Content available remote Badania połączeń spawanych laserem z zastosowaniem mikroskopii akustycznej
PL
W artykule przedstawiono wyniki badań mające na celu określenie możliwości zastosowania mikroskopii akustycznej do oceny jakości oraz identyfikacji niezgodności wewnętrznych połączeń spawanych techniką laserową. W ramach badań opracowano prototypowe stanowisko do skaningowej mikroskopii akustycznej, posiadające szerokie możliwości adaptacji do geometrii badanego obiektu oraz wyposażone w odpowiednie oprogramowanie zawierające algorytmy analizy i obróbki obrazów typu B-scan or C-scan. Wykorzystując wspomniane stanowisko przeprowadzono badania spoin czołowych, na podstawie których wyznaczono głębokość wtopienia spoiny. Wyniki badań zostały zweryfikowane poprzez badania metalograficzne.
EN
The article presents chosen results obtained during the investigation of laser welded joints using acoustic microscopy method. For the purpose of the research a prototype setup was built. This system can be easily adjusted to the geometry of the object and is well equipped with appropriate software containing algorithms for the analysis and processing of images such as B-scan or C-scan. Using the research setup the geometry of the weld can be determined, especially in this particular case the depth of the weld penetration. The results were verified by metallographic examination.
EN
Performed investigations and obtained results concerned the analysis of residual stresses in near-surface areas of coppercorundum (Cu-Al2O3) composite and silicon carbide (SiC) samples. X-ray diffraction and acoustic tomography techniques, as well as the suitable calculation procedures, allowed to locate sample-areas with extreme values of stresses residing in the examined materials. The registered texture-stress characteristics reflects inhomogeneity of the samples structure identified by means of acoustic tomography. Obtained results provide valuable information on anisotropy of physical properties of structural elements produced by the technologies applied to the examined samples.
PL
Przeprowadzone badania i uzyskjane wyniki dotyczyły analizy naprężeń w pobliżu obszarów powierzchniowych dwóch typów materiałów: kompozytów CU-AI2O3 oraz węglika krzemu (SiC). Do zlokalizowania obszarów skrajnych wartości naprę- żeń w badanych materiałach użyto dwóch technik dyfrakcji rentgenowskiej i tomografii akustycznej wykorzystując skaningowy mikroskop akustyczny. Zarejestrowana tekstura krystalograficzna oraz naprężenia własne odzwierciedlają niejednorodność próbek zidentyfikowaną za pomocą tomografii akustycznej. Uzyskane wyniki stanowią cenne informacje na temat anizotropii właściwości fizycznych elementów konstrukcyjnych.
PL
Istotnym czynnikiem decydującym o jakości odlewów ciśnieniowych jest ich porowatość. W pracy testowano przydatność wybranych metod badania porowatości odlewów ciśnieniowych wytwarzanych ze stopu magnezu AZ91. Stosowano następujące metody: pomiary gęstości, rentgenowską tomografią komputerową i mikroskopią akustyczną. Określono zalecany zakres zastosowań poszczególnych metod.
EN
The porosity is an important determinant of the pressure die-castings quality. The study examined the usefulness of selected methods for testing the porosity in pressure castings of the AZ91 magnesium alloy. The following methods were tested: density measurements, computed tomography and acoustic microscopy. The recommended range of application of each method was given.
EN
This study presents a novel approach to measure the enamel thickness potentially applicable to the veneer placing procedure. All experiments have been carried out on the extracted human teeth, using a high frequency ultrasonic transducer (50 MHz, Sonix, Springfield, VA, USA). The enamel thickness measurement results obtained with high positional accuracy by a scanning acoustic microscope (Tessonics AM1103, Windsor, ON, Canada) were compared with the measurements conducted in a hand-held mode by using the same transducer placed in a custom fixture. Finally, to validate the ultrasonic measuring results, the samples were cut down the long axis to expose the cross-section. The enamel thickness was measured in several points along the selected part of the exposed cross-section by using an optical microscope (Stemi SV 11, Carl Zeiss AG, Jena, Germany). The values of the enamel thickness received by using the hand-held probe vs. the acoustic microscope were in close proximity (about 10% difference) and were also satisfactory close to the enamel thickness results obtained from the direct cross-sectional measurements (about 12% difference). The authors suggested a measuring procedure that allows avoiding errors related to the ultrasonic beam localization on the tooth surface. The high feasibility of the ultrasonic pulseecho measurements in a hand-held mode was demonstrated.
10
Content available remote Scanning Acoustic Microscope for 3D imaging
EN
A new Acoustic Microscope operating at the frequency up to 200 MHz and allowing for visualization of the internal structures of materials was developed. The system was built basing on the commercially available components and the self-designed acoustic lenses. The dedicated software was developed to control the process of 3D RF-data acquisition, processing and presenting in 2D cross-sections or 3D surface rendering mode. This article describes the technical principles of the constructed microscope and presents the reconstructed images of the designed test-probe and of the integrated circuit.