Monitoring the accuracy of meters by qualified workers and managers is a preventive measure of every organization. The paper focuses on monitoring the accuracy of measuring devices and proposes preventive and corrective actions. The discussed measurement device was tested for accuracy using accuracy indexes Cg and Cgk. The identified deviations in measurements showed that the meter was not fully efficient. Consequently, actions were taken to ensuring that the measurement device is accurate.
PL
Monitorowanie sprawności mierników to działanie prewencyjne każdej organizacji. Pracownicy działów jakości oraz osoby odpowiedzialne za kontrolę i pomiary wyrobów końcowych są zobowiązani do ciągłej kontroli sprzętu pomiarowego. W artykule skupiono się na monitorowaniu dokładności przyrządu pomiarowego oraz zaproponowaniu działań zapobiegawczych i korygujących. Dokładność przyrządu pomiarowego określono za pomocą wskaźników dokładności Cg i Cgk. Stwierdzono, że odchylenia w pomiarach świadczą o tym, że miernik nie jest w pełni sprawny. W związku z tym podjęto działania naprawcze, które zapewniły sprawność przyrządu pomiarowego.