Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  absorption refrigeration
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper presents the possibility of using a high-efficiency trigeneration system to generate electricity, heat and cold for the needs of a large health care facility. The hospital building is an average of several buildings of the same class. It is a typical Polish object built in the second half of the twentieth century and subjected to thermal modernization consisting in insulation of external walls and roof and replacement of windows and external doors. Thermal modernization led the building to a condition that meets the technical requirements for year 2017. Therefore, the conclusions resulting from the work can be applied to the entire group of health care institutions. The demand for electricity was obtained as fifteen-minute periods, while the demand for heat and cold was calculated using the hourly method. The calculations were made on the basis of meteorological data for the Warszawa-Okęcie station. The choice of the most cost-effective option was determined by economic analysis. The considered variants were compared to the basic variant, which is the most typical solution, i.e. a compressor chiller. For the analyzed options, benefits compared to the baseline option were estimated. NPV indicators were calculated, which clearly stated the best scenario, for which electricity and gas prices was then performed.
2
EN
Due to the characteristics of high gas, high geothermal temperature and high strength development in Huainan mine area, thermal hazard problem has become more and more serious and also affects safety and productivity in coal mine. The CCHP (combined cooling heating and power), as a new mode to control thermal hazard, is put forward after advantages and disadvantages of all kinds of cooling methods are investigated. The CCHP method not only takes full advantage of gas but also reduces the greenhouse gas emission. At the same time, the application of CCHP remits the pressure of the power supply in summer, providing guarantee for safe and high efficiency exploitation.
PL
W związku z wysoką gazonośnością, wysoką temperaturą pierwotną górotworu i wysokimi wartościami zawartości metanu w kopalni Huainan zaobserwowano zagrożenia natury cieplnej, wpływające również na bezpieczeństwo i wydajność produkcji w kopalni. Po zbadaniu wad i zalet różnych metod klimatyzacji podjęto decyzję o wprowadzeniu systemu trójgeneracji jako nowego sposobu kontroli zagrożeń natury cieplnej. Metoda trójgeneracji nie tylko wykorzystuje pełen potencjał ujętego gazu, ale również pozwala obniżyć emisję gazów cieplarnianych. Zastosowanie tego systemu zmniejsza ponadto pobór energii zasilającej w porze letniej, dając gwarancję bezpiecznej i wydajnej eksploatacji kopalni.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.