Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 75

Liczba wyników na stronie
first rewind previous Strona / 4 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  X-ray
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 4 next fast forward last
EN
Changes in microstructure and microhardness are reported, depending on the processing parameters of galvanizing Fe-0.4Mn-0.02Si (S235) and Fe-1.4Mn-0.2Si (S355) steel substrates. The thickness of the coatings depended primarily on the dipping time, 4 and 8 min, which was confirmed by magnetic measurements. XRD analysis and SEM observations revealed typical structures of galvanized coatings, composed of η, ζ, δ and Γ. Microhardness measurements showed that the inner layer δ has the highest microhardness and the phase η has the lowest microhardness. Zn coatings on the Fe-0.4Mn-0.02Si substrate (very low Si content) are characterized by higher adhesion and durability compared to the coatings on Fe-1.4Mn- 0.2Si (higher silicon content).
PL
Przedstawiono zmiany mikrostruktury i mikrotwardości w zależności od parametrów procesu cynkowania na podłożu stali Fe-0,4Mn-0,02Si (S235) i Fe-1,4Mn-0,2Si (S355). Grubość powstałych powłok zależała przede wszystkim od czasu zanurzenia (4 i 8 min), co potwierdziły pomiary magnetyczne. Analiza XRD i obserwacje SEM ujawniły typowe struktury powłok ocynkowanych, złożone z η, ζ, δ i Γ. Pomiary mikrotwardości wykazały, że warstwa wewnętrzna δ ma największą mikrotwardość, a warstwa η najmniejszą. Powłoki Zn na podłożu Fe-0,4Mn-0,02Si (bardzo mała zawartość Si) charakteryzują się lepszą przyczepnością i trwałością w porównaniu z powłokami na Fe-1,4Mn-0,2Si (większa zawartość Si).
EN
High molecular weight chitosan was synthesized from shrimp shells. Chemical structure of chitosan was confirmed using FT-IR, XRD, TGA, and SEM analyses. Physicochemical properties of chitosan such as molecular weight (800 000 g/mol), deacetylation degree (80%), ash content (1%) indicating effectiveness of demineralization step in removing minerals, water binding capacity (4220%), and fat binding capacity (537%), were determined. FT-IR spectra exhibited characteristic joint band at 3365 cm-1 due to –OH and –NH2 regarding to the conversion of chitin acetyl group to NH2 of chitosan.
PL
Z muszli krewetek zsyntetyzowano chitozan o wysokiej masie cząsteczkowej. Strukturę chemiczną chitozanu potwierdzono metodami FT-IR, XRD, TGA i SEM. Określono właściwości fizykochemiczne chitozanu takie jak masa cząsteczkowa (800 000 g/mol), stopień deacetylacji (80%), wskazu jącą na skuteczność procesu demineralizacji zawartość popiołów (1%), zdolność wiązania wody (4220%) i zdolność wiązania tłuszczu (537%). Widma FT-IR wykazały charakterystyczne pasmo przy liczbie falowej 3365 cm-1, pochodzące od grup –OH i–NH2, wynikające z przekształcenia grupy acetylowej chityny w NH2 chitozanu.
EN
Textile research is being driven to find sustainable materials as an alternative to raw fibers. In fact, reusing fibrous waste, as a byproduct, is one of the most important environmental challenges that confront the world. This research focused on studying pulled wool fibers as a natural fiber to reduce environmental loading. There are large amounts of residual pulled wool fibers that can be recycled and valorised. Therefore, raw and pulled wool fibers were characterized and compared. Scanning Electron Micrographs (SEM) results show that on the pulled wool fiber, the surface became rougher and the scales appear affected and less dense. Based on the X-ray diffraction (XRD) results, the crystallinity of the pulled fiber decreased lightly. Attenuated Total Reflectance-Fourier Transform Infra Red (ATR-FTIR) spectroscopy analyzes presented some changes in chemical composition. A High-Performance Liquid Chromatography (HPLC) test showed an increase in the amount of cystic acids. The pulled wool fiber indicates that it might have damaged some crosslinks of macromolecular chains in the fiber. Thus, physical, chemical and mechanical properties are affected during the chemical unhairing process. This research purpose was to increase the potential for better value of pulled wool as it presents the natural fiber most used in several applications.
EN
Introduction: Advances in digital detector technology and methods of image presentation in digital mammography now offer the possibility of implementing mathematical assessment methods to quantitative image analysis. The aim of this work was to develop new software to simplify the application of the existing international standard for DQE in digital mammography and show in detail how it can be applied, using a Siemens Mammomat Inspiration as a model. Material and methods: Consistent with the IEC standard a 2 mm Al filter at the tube exit and images in DICOM format as raw data, without applying any additional post-processing were used. Measurements were performed for W/Rh anode/filter combination and different tube voltage values (26 ÷ 34 kV) without any anti-scatter grid. To verify new software doses ranging from 20-600 μGy were used in measurements. Exposure (air kerma) was measured using a calibrated radiation meter (Piranha Black 457, RTI Electronics AB, Sweden). MTF was determined, using an edge test device constructed specifically for this work. Results: It has been demonstrated that with the new software the DQE can be measured with the accuracy required by the international standard IEC 62220-1-2. DQE has been presented as a function of spatial frequency for W/Rh anode/filter combination and different tube voltage. Conclusions: New software was used successfully to analyze image quality parameters for the Siemens Mammomat Inspiration detector. This was done on the basis of an internationally accepted methodology. In the next step, mammographs with different detector types can be compared.
PL
Śląskie Centrum Radiometrii Środowiskowej, działające w strukturach Głównego Instytutu Górnictwa, od lat zajmuje się ochroną radiologiczną oraz radioekologią. Ochrona radiologiczna jest bardzo szerokim tematem obejmującym między innymi monitorowanie dawek w środowisku pracy. W celu oceny dawek, jakie otrzymują osoby pracujące w warunkach narażenia na promieniowanie jonizujące, powszechnie stosuje się metodę detektorów termoluminescencyjnych. Metoda ta jest akceptowana w większości krajów. Cały proces oceny dawki za pomocą takich dozymetrów można podzielić na kilka etapów. Niewątpliwie jednym z najważniejszych jest etap kalibracji. W artykule przedstawiono wyniki napromieniowania dozymetrów Panasonic UD-802 w polach promieniowania rentgenowskiego o różnych energiach oraz pod różnymi kątami (0°, 30°, 60°). Na podstawie wyników otrzymanych podczas naświetlań wyznaczono współczynniki kalibracji.
EN
The Silesian Center of Environmental Radiometry, operating within the structures of the Central Mining Institute, has been dealing with radiological protection and radioecology for many years. Radiation protection is a very broad topic, including, inter alia, the monitoring of doses in the work environment. In order to assess the doses received by people working in conditions of exposure to ionizing radiation, the method of thermoluminescent detectors is commonly used. This method is accepted in most countries. The entire process of dose evaluation with such dosimeters can be divided into several steps. Undoubtedly, one of the most important is the calibration step. The article presents the irradiation results of Panasonic UD-802 dosimeters in X-ray fields of different energies and at different angles (0°, 30°, 60°). Based on the results obtained during the irradiation, the calibration coefficients were determined.
EN
Surface-mount technology is now widely used in the production ofmany components. The development of the miniaturised electronics industry forces the development of increasingly accurate inspection methods. X-ray and computed tomography are methods to accurately assess the quality of a circuit . The article discusses the basics of image formation of the tested electronics, the development of the design of the devices used and examples of x-ray, computed tomography applications.
PL
Obecnie technologia montażu powierzchniowego jest szeroko stosowana w produkcji wielu podzespołów. Rozwój zminiaturyzowanego przemysłu elektronicznego wymusza rozwój coraz to dokładniejszych metod inspekcji. Metodami pozwalającymiw dokładny sposób ocenić jakość płytki drukowanej jest wykorzystanie promieniowania rentgenowskiegoi tomografii komputerowej. W artykule omówiono podstawy powstawania obrazów badanej elektroniki, rozwój konstrukcji wykorzystywanych urządzeń, przykłady zastosowań RTG i tomografii komputerowej.
PL
W artykule opisano problematykę pomiarów przedziałów czasu równych czasowi ekspozycji promieniowania X. Pokazano zależność niepewności pomiaru od metody pomiarowej oraz od sposobu działania źródła promieniowania rentgenowskiego. Przedstawiono wpływ zakresu przedziału czasu mierzonego przez miernik na błąd pomiaru.
EN
The main idea of the article is a description of problems of X-ray exposure time measurement. The content describes two types of X-ray machines. Among the two X-ray machine types, continuous type with shutter is more suitable for long time measurement, and pulse type is better for short time measurements. The differences between mode of operation of different X-ray sources and it’s impact on uncertainty of measurement of exposure time are presented. It also discusses the impact of different resolution settings of device under calibration on uncertainty measurement.
PL
W marcu 1896 roku, czyli po czterech miesiącach od odkrycia Wilhelma Konrada Roentgena, promieniowanie X zostało wykorzystane pierwszy raz podczas działań wojennych. Radiogram przedramienia żołnierza rannego w Abisynii (współczesna Etiopia) wykonał Giuseppe Alvaro, podpułkownik włoskiej armii. W zasadzie nie można wskazać żadnego konfliktu zbrojnego XX wieku, gdzie nie byłaby wykorzystywana rentgenodiagnostyka. Celem pracy jest charakterystyka dwóch kontrastujących aspektów wykorzystania promieniowania rentgenowskiego – humanitarnej postawy Marii Skłodowskiej-Curie oraz zbrodniczych eksperymentów Carla Clauberga i Horsta Schumanna.
EN
In March 1896, four months after the discovery of Wilhelm Konrad Roentgen, X-rays were used for the first time during the war. The radiography of the forearm of a soldier wounded in Abyssinia (Ethiopia) was taken by Giuseppe Alvaro. In principle, it is impossible to point out any armed conflict of the 20th century where radiography would not be used. The aim of the study is to characterize two contrasting aspects of the use of X-rays – the humanitarian of Marie Sklodowska-Curie and the criminal experiments of Carl Clauberg and Horst Schumann.
PL
W artykule opisano problematykę pomiarów przedziałów czasu równych czasowi ekspozycji promieniowania X. Pokazano zależność niepewności pomiaru od metody pomiarowej oraz od sposobu działania źródła promieniowania rentgenowskiego. Przedstawiono wpływ zakresu przedziału czasu mierzonego przez miernik na wielkość błędu.
EN
Main idea of the article is a description of problems of X-ray exposure time measurement. Content describes two types of X-ray machines. Among the two X-ray machine types, continuous type with shutter is more suitable for long time measurement, and pulse type is better for short time measurements. The article discuss differences between mode of operation of different X-ray sources and it’s impact on uncertainty of measurement of exposure time. It also discuss impact of different resolution settings of device under calibration on uncertainty measurement.
EN
We present the results of the stabilization of the γ-U phase with a cubic structure in U-T alloys by means of combined ultrafast cooling (with a cooling rate 106 K/s) and doping with alloying elements in the VI and VIII group (T = Mo, Pt, Nb, Ru, Ti). The X-ray diffraction data have confirmed the cubic structure presented in all U-T alloys with the alloying element content T≥15 at.% (atomic percentage concentration). Some results of the microstructure analysis, phase distribution and orientation of selected samples by using electron backscatter diffraction are also shown.
PL
Zaprezentowaliśmy wyniki stabilizacji fazy γ-U ze strukturą kubiczną w związkach U-T za pomocą techniki ultraszybkiego chłodzenia (z szybkością chłodzenia 106 K/s) oraz domieszkowania pierwiastkami z grup VI i VIII (T= Mo, Pt, Nb, Ru, Ti). Dane dyfrakcji rentgenowskiej potwierdziły obecność kubicznej struktury we wszystkich związkach U-T posiadających zwartość pierwiastków domieszkujących T≥15 at.% (procent atomowy). Wyniki analizy mikrostruktury, rozkładu fazowego i orientacji wybranych próbek zostały również pokazane, używając dyfrakcji wstecznego rozpraszania elektronów.
EN
The article presents an analysis of the change in air voids in asphalt mixtures subjected to fatigue tests at three temperatures of 0°C, 10°C and 25°C. The X-ray computerized tomography imaging method, XCT, was used to identify the air voids in the samples. The research allowed to determine changes in the content of air voids in subsequent fatigue cycles in the sample area. The relationship between air voids volume and the stiffness modulus value was also determined during fatigue for three temperatures. The largest changes were found in samples with notches at 0°C. The analysis of the change in the content of air voids showed that the micro-cracking nucleation processes develop with the number of fatigue cycles. Using the numerical model finite element method we determined the distribution and change in fatigue damage in the extreme areas of the sample during various stages of fatigue. We found clear relationship between the damage and the increased content of air voids.
EN
In this report, ternary semiconducting NixBi2−xS3(x = 0.2 M and 0.5 M) thin films were synthesized in situ for the first time by a chemical bath deposition technique at different bath temperatures (60 °C, 70 °C and 80 °C). The effects of concentration and deposition temperature on the deposited films were studied by combining the results of structural, morphological, optical and electrical analyses. The growth of NixBi2−xS3 films with good crystalline nature and interconnected grain arrangement takes place due to increasing the concentration of Ni2+ ions in bismuth sulfide matrix. EDS result confirmed the stoichiometry of NixBi2−xS3 formation. Wettability test demonstrated that the surface of the film was hydrophilic in nature. The optical absorption spectra revealed that the bandgap Eg of the x = 0.5 M film deposited at 70 °C was about 1.36 eV. Current-voltage (I-V) characteristics of the x = 0.5 M film deposited at 70 °C were studied under X-ray radiation and dark condition. An X-ray detection sensitivity analysis showed that the detection sensitivity is optimum when the bias voltage applied across the film is low (~0.9 V). These findings reveal that the film with x = 0.5 M deposited at 70 °C can be used as an efficient low cost X-ray sensor.
13
Content available remote Kolimacja w radiografii obustronnej stóp
PL
Obustronna radiografia stóp ogranicza narażenie pacjenta na dodatkową ekspozycję, a także pozwala na analizę porównawczą obu stóp. Badanie to stosowane jest głównie w diagnozowaniu reumatoidalnego zapalenia stawów, ale jest też pomocne w różnicowaniu innych schorzeń zapalnych stawów. Optymalnie dobrane warunki ekspozycji i pole kolimacji mają wpływ na wartość współczynnika DAP, jak również istotne znaczenie z punktu widzenia ochrony radiologicznej. Cel: Praca ma na celu retrospektywną ocenę pola kolimacji w radiografii obustronnej stóp oraz określenie wpływu wielkości obszaru diagnostycznego zainteresowania na wartość DAP. Materiały i metody: Badaniu poddano 108 porównawczych zdjęć rentgenowskich stóp wykonanych w okresie od 1 stycznia 2016 roku do 31 stycznia 2017 roku w Zakładzie Radiologii Uniwersyteckiego Szpitala Klinicznego w Białymstoku. Przeprowadzono pomiar długości i szerokości radiogramów. Na podstawie uzyskanych danych wyliczono pole kolimacji. Uzyskane wartości porównano z wartością referencyjną – 720 cm2 (24 x 30 cm). Obliczenia statystyczne wykonano przy użyciu programu MS Excel 2016 oraz Statistica 12. Wyniki: Większość radiogramów (79,63%) wykonano wśród kobiet. Wiek pacjentów mieścił się w przedziale od 19 do 77 lat. Średnie wymiary zdjęcia wynosiły 23,76 cm x 24,86 cm, a wartość pola kolimacji 594,47 cm2. 18 (16,67%) radiogramów miało pole większe niż przyjęta wartość referencyjna. Statystycznie najczęściej wybierane parametry to 55 kV oraz 2,63 mAs. DAP przyjmował wartości od 2,80 cGy•cm2 do 6,80 cGy•cm2, ze średnią wynoszącą 4,01 cGy•cm2. Wnioski: Średnia wielkość pola kolimacji wyniosła mniej niż wartość referencyjna. Największe wartości DAP występowały w grupie radiogramów o polu z zakresu 600-960 cm2.
EN
Bilateral feet radiography limits the patient’s risk to additional radiation exposure and allows a comparative analysis of both feet. This examination is mainly used for the diagnosis of rheumatoid arthritis but it’s also helpful in differentiation other inflammatory joint diseases. Optimally selected exposure parameters and collimation field affect value of the DAP factor, as well as have a significant importance for the radiological protection. Aim: The aim of the study was retrospective evaluation of collimation field in bilateral feet radiography and to determine the impact of the size of the diagnostic area of interest on the DAP factor value. Materials and methods: 108 comparative feet X-rays taken in Radiology Department of the Medical University of Bialystok Clinical Hospital from 1.01.2016 to 31.01.2017 were analyzed. A measurement of the length and width of the radiographs were made and the collimation field was calculated based on the obtained data. Acquired values were compared with a reference value - 720 cm2 (24x30 cm). Statistical calculations were done with MS Excel 2016 and Statistica 12. Results: Majority of radiograms (79.63%) were performed on women. The range of the patients age was from 19 to 77 years. Average dimensions of the X-ray were 23,76 cm x 24,86 cm and average collimation field was 594,47 cm2. 18 (16.67%) of all radiograms had field bigger than reference value. Statistically most often chosen parameters were 55 kV and 2,63 mAs. The DAP factor took values from 2,80 cGy•cm2 to 6,80 cGy•cm2, with an average of 4,01 cGy•cm2. Conclusions: The average size of the collimation field was smaller than its reference value. The biggest values of the DAP factor were in the group of radiograms with the field range from 600 to 960 cm2.
EN
Iterative reconstruction methods in Computed Tomography (CT) are known to provide better image quality than analytical methods but they are not still applied in many fields because of their computational cost. In the last years, Graphical Processor Units (GPU) have emerged as powerful devices in order to parallelize calculations, but the efficiency of their use is conditionned on applying algorithms that can be massively parallelizable. Moreover, in non-destructive testing (NDT) applications, a segmentation of the reconstructed volume is often needed in order to have an accurate diagnosis on the material health, but performing a segmentation after the reconstruction introduces uncertainties in the diagnosis from both the reconstruction and the segmentation algorithms. In this paper, we propose an iterative reconstruction method for 3D CT that performs a joint reconstruction and segmentation of the controlled object in NDT for industrial applications. The method is based on a 3D Gauss-Markov-Potts prior model in Bayesian framework, which has shown its effective use in many image restoration and super-resolution problems. First, we briefly describe this model, before deriving the expression of the joint posterior distribution of all the unknowns. Next, an effective maximization of this distribution is presented. We use a ray-driven projector and a voxel-driven backprojector implemented on GPU. The algorithm is developed so it can be massively parallelized. Finally, we present our results on simulated and real phantoms. In addition, we investigate further reconstruction quality indicators in order to compare our results with other methods.
EN
4,6-Diazido-N-(2,4,6-trinitrophenyl)-1,3,5-triazin-2-amine (TNADAzT) and its silver salt (AgTNADAzT) were prepared and characterized. Elemental analysis, FTIR, NMR, DSC, AAS and X-ray diffraction were used for analytical characterization. The sensitivities of TNADAzT and AgTNADAzT were determined and compared with common explosives and MTX-1. The crystal density of TNADAzT is 1.794 g·cm−3 and its heat of formation 899 kJ·mol−1. The sensitivity of TNADAzT to impact and friction slightly exceeds PETN; the sensitivity to electrostatic discharge is lower than RDX. The sensitivity of AgTNADAzT is on the level of a primary explosives (between mercury fulminate and PETN). The initiation efficiency of AgTNADAzT is higher than 200 mg (acceptor PETN compressed by 64-70 MPa) and therefore excludes it from practical use as a primary explosive in detonators.
PL
Stale zwiększająca się liczba zakładów radiodiagnostyki przekłada się na większą dostępność do badań z zakresu rentgenodiagnostyki konwencjonalnej, co powoduje zwiększenie liczby wykonywanych zdjęć rentgenowskich, a tym samym wzrost liczby zdjęć odrzuconych i powtórzonych. Celem pracy jest poszukiwanie grup badań obarczonych zwiększonym ryzykiem błędu, a przez to koniecznością ich powtórzenia na podstawie analizy wykonanych i powtórzonych zdjęć rentgenowskich. Przeprowadzonoretrospektywnąanalizę22454zdjęć rentgenowskich wykonanych w latach 2011-2014. Spośród nich wyodrębniono grupę 1101 zdjęć odrzuconych. Wszystkie zdjęcia należące do grupy odrzuconych zostały powtórzone. Następnie zdjęcia te oceniono, dzieląc na grupy ze względu na rodzaj badania i analizując każdą z grup osobno. Zwrócono także uwagę na zależność czasową liczby powtarzanych zdjęć rentgenowskich w kolejnych miesiącach oraz latach okresu objętego analizą. Otrzymane wyniki pozwoliły wyodrębnić rodzaje badań, które mają podwyższone ryzyko przekroczenia zalecanego odsetka zdjęć powtórzonych, co pozwoli na zwrócenie szczególnej uwagi i zachowanie zwiększonej ostrożności podczas wykonywania ich w przyszłości. Kolejnym planowanym przez autorów krokiem jest poszerzenie zebranej bazy danych o badania wykonane do dnia bieżącego i uzupełnienie jej o informacje dotyczące przyczyny odrzucenia zdjęć, co pozwoli na bardziej dogłębną analizę potencjalnych czynników predysponujących do popełnienia błędu.
EN
The constant growth of number of radiology departments means greater availability of conventional X-ray, which increases the amount of X-rays performed, and thus elevate the number of rejected and repeated examinations. The aim of the study was to seek groups of examinations with increased risk of error and therefore the need to be remade on the basis of analysis of performed and repeated x-ray images. A retrospective analysis of 22,454 X-ray images taken in 2011-2014 was performed. Among them a group of 1,101 rejected images was distinguished. All examinations, that have been rejected have been repeated. These examinations were divided into groups according to the type of examination and each group was analyzed separately. Temporal distribution of repeated X-rays in the months and years of the analysis period was noted. The obtained results allowed to distinguished types of studies, which have increased the risk of exceeding the recommended percentage of repeated images. This knowledge will result in special attention and more cautious behavior during examinations in the future. Another step planned by the authors is to widen the database of research done and supplement it with information about the reasons for the rejection of examination, which will allow for more accurate analysis of potential factors predisposing to a mistake.
17
Content available remote On J-additivity and Bounded Additivity
EN
In this paper we consider the uniqueness issues in Discrete Tomography. A special class of geometric objects, widely considered in the literature, is represented by additive sets. These sets are uniquely determined by their X-rays, and they are also reconstructible in polynomial time by use of linear programming. Recently, additivity has been extended to J-additivity to provide a more general treatment of known concepts and results. A further generalization of additivity, called bounded additivity is obtained by restricting to sets contained in a given orthogonal box. In this work, we investigate these two generalizations from a geometrical point of view and analyze the interplay between them.
EN
Purpose: Article concern studies of the method using X-ray as a source to analyse products made of the steel mixture powder after compaction “green parts” on the example of the engine and gearbox parts. Mentioned methods are used to detect defects like surface cracks and inner material cracks, as well as density distribution without violations of their functional properties. Design/methodology/approach: Presented techniques are evaluating on the typical sintered engine and gearbox parts like pulley and synchronizing hub. All methods have advantages and disadvantages, therefore are compression between them essential, especially concerning used in industrial conditions including zero waste manufacturing. Findings: Evaluation of the nowadays used methods and trends used for “green part” made of steel mixture powder are very important. Moreover presents a future trends and future development directions will be provided by this article. Research limitations/implications: Methods are tested on the “green parts” made of the steel mixture powder for automotive application and mostly depending on the industrial conditions for such products. Practical implications: Methods should be able to use in the industrial conditions to assure good quality parts without defects and well-documented density distribution without destroying the object. Originality/value: Analyse of the nowadays methods using for evaluation of the “green parts” quality after compaction of the steel mixture powder are still undergoing rapid development.
EN
This article presents an analysis of the phenomenon of X-ray generated from partial discharges. The measurement data have been analyzed in MATLAB environment. Previous studies showed the relationship between the increase in voltage between electrodes, and both, the energy and the number of ionizing acts. In another study, the modified initial conditions confirmed the existence of X-ray radiation generated by the PD. The changes were related to the spark gap material.
20
PL
Artykuł opisuje wykorzystanie hybrydowych detektorów promieniowania X do wysokiej jakości obrazowania cyfrowego. Przedstawione są zalety i wady binarnego przetwarzania sygnału z detektora ze wskazaniem na jego krytyczne elementy związane z jakością obrazu, tj. niski poziom szumów oraz jednorodność kanałów w układzie scalonym. Zaprezentowane rozwiązanie, wykorzystujące przetworniki korekcyjne w każdym kanale, pozwala na zmniejszenie rozrzutów. Aby jednak mogły one być efektywnie stosowane w praktycznej aplikacji niezbędne jest wypracowanie efektywnego algorytmu korekcji umożliwiającego wykonanie całej procedury w czasie poniżej jednej minuty.
EN
The article describes the use of hybrid pixel detector for high quality digital X-ray imaging. Both pros and cons of binary readout are discussed with two critical parameters, namely a low noise level and an offset spread among readout channels, which are the main sources of decreasing image quality. Presented solution, which uses the trimming circuit in every readout channel allows minimization of the offset spread. They require however an effective and fast algorithms for finding an optimum value in less than a minute to be used in practical application.
first rewind previous Strona / 4 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.