Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  UPLC/MS/MS
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
An ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method was developed and validated for quantification of ligustroflavone, which was then applied in pharmacokinetics study in rat and tissue distribution in mouse. Twelve male Sprague Dawley rats were used for pharmacokinetics after intravenous (2 or 8 mg/kg) administration of ligustroflavone, six rats for each dose. Twenty-five mice were randomly divided into 5 groups (5 mice for each group, 1 group for each time point) and received 16 mg/kg ligustroflavone via intraperitoneal administration. The linear range of the calibration curve was over 2–2000 ng/mL for ligustroflavone in rat plasma and mouse tissues. The intra-day and inter-day precision expressed in % RSD were less than 14%, and the accuracy was between 88.5% and 108.4%.
EN
Dabigatran with IUPAC name 3-({2-[(4-Carbamimidoyl-phenylamino)-methyl]-1-methyl-1H-benzoimidazole-5-carbonyl}-pyridin-2-yl-amino)-propionic acid, which can be used to prevent strokes in those with atrial fibrillation due to causes other than heart valve disease, and at least one additional risk factor for stroke (congestive heart failure, hypertension, age, diabetes, and prior stroke), with molecular formula C34H41N7H5 was studied in detail for functional group analysis with FTIR, characteristic absorbance by UV-NIR, thermal behavior by TGA-DTA-DSC, particle size and stability of the molecule with Nano particle size analyzer. The structure was confirmed by LC-MS/MS with ESI probe and mass was found in aggregation with the reported standard values. The purity of drug was determined by Prep. HPLC analysis. FTIR analysis showed the characteristic peak of carboxylic acid, UV-NIR analysis showed that the λmax was 224 nm with methanol as a diluent, the compound was found stable in the thermal analysis, the average particle size was found to be 25.2 nm, Z-average as 0.2 nm and zeta potential as -67.6 mv hence showed excellent stability in the zeta potential analysis as per ASTM standards D4187-82, American Society of Testing and Materials, 1985.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.