Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 15

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  UHF
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Accomplishment of basic services implementation with specific quality is one of the main challenges of the command and communication systems for modern maritime safety and defense. The specificity of the marine environment imposes the use of narrowband HF (High Frequency) and VHF (Very High Frequency) radio communication devices which are capable to implement IP transmission. This paper presents the requirements for the HF and VHF radio systems according to the IP protocol requirements. At the beginning basic properties of narrowband HF and VHF waveforms in context of their operational scenarios has been described. Then results of experimental research (implementation of narrowband services — voice and data) has been presented. Finally further research directions with contribution of the authors, in NATO working groups related to the development of NBWF (Narrowband Waveform) for coalition communication has been presented.
PL
Jednym z głównych wyzwań stawianych współczesnym systemom dowodzenia i łączności działającym na rzecz zapewnienia bezpieczeństwa i obronności morskiej jest realizacja odpowiedniej jakości usług podstawowych. Specyfika działania systemów morskich wymusza wykorzystanie wąskopasmowych środków łączności radiowej pracujących w zakresie KF i UKF. Odpowiednie waveformy wąskopasmowe pozwalają na realizację transmisji IP. W artykule przedstawione zostały wymagania stawiane środkom łączności radiowej KF i UKF w celu zapewnienia realizacji transmisji IP. Opisano podstawowe właściwości waveformów wąskopasmowych KF i UKF oraz sposób ich użycia w systemach morskich (scenariusze operacyjnego wykorzystania). Przedstawione zostały także wyniki badań eksperymentalnych (realizacja usług wąskopasmowych — głos i dane) oraz dalsze kierunki badań ze szczególnym uwzględnieniem udziału autorów artykułu w grupach roboczych NATO związanych z opracowaniem waveformów wąskopasmowych NBWF do łączności koalicyjnej.
PL
Badanie wyładowań niezupełnych jest jedną z najczęściej stosowanych metod kontroli jakości izolacji w układach eklektycznych. W przypadku transformatorów mocy pomiary te wykonuje się bazując na dobrze znanych i ustalonych standardach międzynarodowych. Detekcja wyładowań niezupełnych w wysokich częstotliwościach jest jedną z metod najbardziej rozwijanych w ostatnich latach, a przez swoją łatwość w implementacji oraz możliwość wykorzystania w systemach monitoringu sprawia, że jest ona coraz częściej postrzegana, jako uzupełnienie lub wręcz alternatywa dla metody elektrycznej podczas odbiorów fabrycznych.
EN
Investigation of partial discharges is one of the most commonly used methods of controlling the quality of insulation in electric systems. In the case of power transformers, these measurements are performed based on well-known and established international standards. Detection of partial discharges at high frequencies is one of the most developed methods in recent years, because of its ease implementation and possibility of utilization in monitoring systems. It is more often perceived as an accompanying or even substitute for the electrical method during factory tests.
EN
The Ground Penetrating Radar (GPR) technique finds immense applications in civil engineering today, as the most suitable approach for non-destructive testing of pavements, highways, concrete structures, and more. The major challenge in carrying out a GPR evaluation is that the properties of the probed medium are usually unknown. The permittivity and conductivity of the medium may vary from those of air to water. The electromagnetic waves also have a frequency dependent attenuation. The ability of GPR to detect signals reflected and scattered by the targets largely depends upon the antenna performance. This paper studies a novel 11:1 wideband loop bowtie antenna with very good radiation properties in the entire operating bandwidth. Synthetic and experimental results are presented for the return loss and gain of the antenna. Furthermore, experimental results are presented for the radiation patterns in the E- and H-plane. We also used the antenna to measure B-scans over two different pipes, a bamboo, and a reinforced concrete structure. All results obtained with the proposed antenna have been compared with results obtained by using a RC loaded antenna. It has been found that the loop bowtie antenna has excellent detection capability and produces less clutter. The loop loading technique can be applied to existing antennas for improved GPR imaging. This will improve the detectability of GPR by improving the target return signal.
PL
Celem artykułu było przedstawienie wyników badań oceny efektywności przetwarzania energii pola elektromagnetycznego w układzie P2110 firmy Powercast. W ramach omawianego zagadnienia ujęto aspekty związane z pozyskiwaniem małych ilości energii do zasilania autonomicznych układów elektronicznych o zmniejszonym zapotrzebowaniu na moc. Potencjał energetyczny otaczającego środowiska, eliminacja zagrożeń środowiskowych, a także wzrost funkcjonalności nowoczesnych systemów elektronicznych są istotnymi czynnikami przemawiającymi za opracowaniem efektywnych rozwiązań w zakresie pozyskiwania, przetwarzania oraz gromadzenia energii. Technika pozyskiwania/recyrkulacji energii (Energy Harvesting) znajduje zastosowanie w wielu różnych obszarach aktywności społeczno-gospodarczej człowieka. Na przestrzeni ostatnich lat w środowisku obserwuje się wzrost poziomu pól elektromagnetycznych, których źródłem są różnego rodzaju systemy radiokomunikacyjne. Przenoszona przez nie energia może zostać pozyskana i wykorzystana do celów niezwiązanych z funkcjonowaniem wspomnianych systemów. Obecnie brak jest efektywnych rozwiązań pozwalających na przetwarzanie energii pól o bardzo niskich poziomach przy dużym zakresie zmienności tych poziomów. Jednym z nielicznych komercyjnie dostępnych struktur realizujących taki proces jest układ P2110. W niniejszym artykule przedstawiono sposób doświadczalnego wyznaczenia sprawności przetwarzania energii przez taki układ za pomocą metody, która nie wymaga użycia zaawansowanej aparatury pomiarowej. Na potrzeby badań wygenerowano sztuczne pole elektromagnetyczne, w którym umieszczono układ pozyskujący energię – P2110. Zmiana odległości pomiędzy anteną generującą pole elektromagnetyczne, a układem P2110, umożliwiła realizację pomiarów i ocenę wpływu poziomu mocy wejściowej na sprawność przetwarzania energii w warunkach zbliżonych do rzeczywistych - aplikacyjnych. Wyniki pokazują, że układ osiąga relatywnie dużą sprawność dla poziomu mocy wejściowej wyższego niż -7 dBm. Istotny wpływ na sprawność przetwarzania ma również wartość rezystancji obciążenia. Wzrost obciążenia powoduje obniżenie wartości tego parametru.
EN
The aim of this article was to present the investigation results of the energy conversion efficiency in Powercast P2110 Powerharvester. In this subject the aspect of low power energy harvesting has been included. The energy potential of the surrounding environment, the elimination of environmental threats, as well as the increased functionality of electronic modern systems are crucial factors that suggest development effective solutions in the scope of harvesting, processing and energy storing. The energy harvesting technique is useful in many various areas of human social-economic activity. During last years, there was an increase of the electromagnetic fields level observed in the environment. These fields are produced by various types of communications systems. The energy which is transmitted can be harvested and utilized for purpose not associated with the mentioned systems. Currently, there are no effective solutions to energy conversion fields at very low power level and a high variability of these levels. One of the few commercially available solutions to convert rf energy is the Powercast P2110 Powerharvester. The experimental methods of determining energy conversion efficiency in such circuit were presented in this paper. The used methods do not require advanced measurement. The electromagnetic field was generated for research. In the created electromagnetic environment P2110 Powerharvester was placed. A change of distance between the antenna generating an electromagnetic field and P2110 Powerharvester enabled implementation of measurements and estimation the influence of input power level on the energy conversion efficiency at the condition similar to the real application conditions. According to the results, the relative high efficiency is observed for input power level greater than -7 dBm. The load resistance has a significant impact on the efficiency of the process. Generally, load increase causes a reduction in the value of of efficiency value.
EN
This article simulates the propagation of ultrahigh frequency (UHF) electromagnetic wave excited by partial discharge in L-shaped and Tshaped branch of GIS using finite-difference time-domain (FDTD) algorithm. We examine the effect of L-shaped and T-shaped branch of GIS on time domain waveform and frequency components of UHF electromagnetic wave. It is found that L-shaped branch of GIS significantly attenuates the electric field strength of UHF electromagnetic wave propagating in GIS cavity. Electromagnetic waves attenuated by L-shaped branch mainly have the frequency of 300MHz-2000MHz or above 3000MHz. Electric field strength of some frequency components is enhanced. When propagating in Tshaped branch, the frequency components of electromagnetic wave are more significantly attenuated along the bending path than along the straight path.
PL
W artykule opisano wyniki symulacji propagacji fali elektromagnetycznej o ultra-wysokiej częstotliwości, wywołanej wyładowaniem niezupełnym w gałęzi typu L i T aparatury rozdzielczej GIS, z wykorzystaniem algorytmu różnic skończonych w dziedzinie czasu (FDTD). Stwierdzono, że gałąź L znacząco osłabia siłę wnikania pola elektrycznego fali elektromagnetycznej UHF w GIS. W gałęzi T, częstotliwości składowe są bardziej tłumione w zagięciach charakterystyki niż na odcinkach prostych.
EN
We perform a simulation study of attenuation characteristics of ultrahigh frequency (UHF) electromagnetic wave excited by GIS partial discharge in salver-shaped insulator using finite-difference time-domain (FDTD) algorithm. First, the attenuation of UHF electromagnetic wave’s electric field signals which is caused by salver-shaped insulator is analysed. It is found that the insulator attenuates electric field strength of UHF electromagnetic wave propagating inside GIS cavity much less significantly as compared with that of UHF electromagnetic wave leaked to outside GIS cavity. Finally, we study the amplitude-frequency characteristics of the gain of electric field signals of UHF electromagnetic wave which is attenuated by the insulator. It is found that UHF electromagnetic wave inside GIS cavity attenuated by the insulator has the frequency above 1000MHz; UHF electromagnetic wave which is leaked to the outside of GIS cavity and attenuated by the insulator has the frequency below 1500MHz and above 3000MHz.
PL
W artykule przedstawiono wyniki badań symulacyjnych charakterystyki tłumienia fali elektromagnetycznej UHF, generowanej przez wyładowanie niezupełne w aparaturze rozdzielczej typu GIS. W analizie posłużono się algorytmem wykorzystującym metodę różnic skończonych w dziedzinie czasu. Przeprowadzono także badania nad charakterystyką amplitudowo-częstotliwościową wzmocnienia składowego pola elektrycznego fali przy tłumiącym działaniu izolatora.
EN
This paper describes a new on-line method for capacitance and dissipation factor measurements of high voltage bushings, for recording grid transients and for partial discharge monitoring at power transformers. The needed accuracy for reliable detection of failures is in the range of 5 pF for capacitance and 0.1 % for dissipation factor. To overcome these shortcomings, this paper introduces an absolute method for measuring capacitance and dissipation factor of HV bushings. As for off-line measurements, the discrimination between noise and true internal discharges is the key for successful diagnosis. Strategies for sensitive partial discharge measurements under disturbed on-line conditions are described, also involving measurements in the UHF range.
PL
Artykuł opisuje nowe metody pomiaru on-line pojemności i współczynnika strat przepustów wysokonapięciowych na potrzeby, monitorowania przepięć w sieci i wyładowań niezupełnych w transformatorach energetycznych. Według statystyk awaryjności przepusty WN są jedną z głównych przyczyn awarii transformatorów, co motywuje operatorów do ciągłego monitoringu on-line stanu układów izolacyjnych. Na potrzeby wiarygodnej diagnostyki wymagana jest dokładność pomiaru pojemności rzędu 5 pF i współczynnika strat rzędu 0,1%. Aby uzyskać taką rozdzielczość, wskutek braku symetrii w sieci, nie wystarczy względne porównanie prądów mierzonych w zaciskach pomiarowych w przepustach trzech faz. Dodatkowo, ten sposób pomiaru nie pozwala identyfikować procesu starzenia przebiegającego w trzech fazach ze zbliżonym tempem. W artykule przedstawiono metodę pomiaru rzeczywistych wartości pojemności i współczynnika strat przepustów WN. Pozwala ona uzyskać dokładność podobną do pomiarów off-line nawet w warunkach eksploatacyjnych. Wyładowania niezupełne są wczesnym wskaźnikiem zbliżającego się przebicia w izolacji WN. Ich pomiar na zacisku przepustu WN umożliwia wykrycie defektów w izolacji przepustu oraz transformatora. Podobnie jak w pomiarach off-line, rozróżnienie zakłóceń od rzeczywistych wyładowań wewnętrz izolacji jest kluczem do poprawnej diagnostyki. Opisano strategie czułego pomiaru wyładowań niezupełnych w warunkach on-line, z uwzględnieniem zakresu UHF.
EN
Gas insulated switchgear (GIS) is the most important equipment in the power grid. The partial discharge (PD) is the premonitory detection method for the insulation failure. The UHF detection method and acoustic detection method is the most used in filed. UHF method has excellent antiinterference performance and acoustic method has excellent defect location ability. Metal tip defect will appear on GIS for manufacturing and other reasons. The metal tip will lead to corona discharge under operating voltage. It is necessary to study the characteristics of corona discharge for fault detection and diagnosis. The experimental system is set up and the corona discharge characteristics on conductor and ground in actual GIS model are studied using above two methods. The comparing of the two methods is studied in this paper.
PL
Wyładowanie niezupełne może być metodą detekcji złej izolacji w przełącznikach gazowych GIS. Doi wykrywania wyładowania najczęściej używa się metody UHV lub akustycznej. Pierwsza z nich jest odporna na zakłócenia druga bardzo dobrze pozwala na lokalizację wyładowania. W artykule przedstawiono porównanie obu metod. (Badanie różnymi metodami wyładowania niezupełnego w przełącznikach gazowych)
EN
Partial discharge (PD) detection is an important means in the condition-based maintenance of high voltage apparatus including crosslinked polyethylene (XLPE) power cables. In this contribution, we introduce the recent work in Shanghai municipal electric power company on the condition-based maintenance of XLPE power cables. As to how to carry out the PD detection in different circumstances, three schemes are laid out in brief. Particularly, a novel idea of partial discharge joint detection method, which is based on multiple sensors, or the high frequency current transformer (HFCT) coupling technique, ultra high frequency (UHF) and acoustics emission (AE) partial discharge detection technique, is proposed. Use more than one kind of coupling techniques, the reliability of onsite PD detection and diagnosis can be improved significantly.
PL
Przedstawiono metody wykorzystania wyładowania niezupełnego do testowania stanu kabli typu XLPE. Wykorzystano różne czujniki, jak np. wysokoczęstotliwościowy transformatorowy czujnik prądu czy czujniki emisji akustycznej.
EN
This article describes results of an analysis of RFID projects carried out in cooperation of small and medium sized Enterprises (SME), Fontys Hogescholen, Venlo, Netherlands and Niederrhein University of Applied Sciences, Moenchengladbach, Germany. Main content and questions are: Who can be a driver and main beneficiaries of the potential of RFID for SME? What are the main objectives to use RFID? Which RFID applications are suitable? Which RFID technologies are used in SME?
EN
Occupational exposure caused by large broadcasting transmitters exceeds current reference levels. As it is common for different radio and TV transmitters to share the location, we analysed combined exposure on a 40-m high mast. The frequency modulation (FM) transmitter, located between the 10th and 30th metre, had the power of 25 kW, whereas an ultra-high frequency (UHF) transmitter of 5 kW occupied the top 8 m of the mast. Measured and calculated values of the electric field strength exceeded the reference levels up to 10 times; however, the results for the specific absorption rate (SAR) values show that the reference levels are very conservative for FM exposure, i.e., basic restrictions are not exceeded even when the reference levels are exceeded 10 times. However, for UHF exposure the reference levels are not conservative; they give a good prediction of real exposure.
EN
A multi-sensor joint detection technology was proposed based on the theory of the high frequency current transformer (HFCT) method, Ultra-high frequency (UHF) method and acoustic emission (AE) method. An experimental partial discharge (PD) testing was applied on XLPE cable with artificial defect signals. The experimental results show that the multi-sensor joint detection technology will help to identify the PD signals from the interference noises and improve the localization accuracy.
PL
Zastosowano wielosensorową metodę badania wyładowania niezupełnego: wysokoczęstotliwościowy transformator prądu oraz metodę emisji akustycznej. Badania przeprowadzono na kablu ze sztucznym sygnałem defektu. Umożliwiło to wydzielenie sygnału z szumów i poprawe dokładności pomiaru lokalizacji.
PL
Gospodarka oparta na wiedzy wymaga coraz szybszego przetwarzania informacji. Jedną z technik, pozwalającą na poprawę efektywności transferu danych, jest identyfikacja radiowa RFID. Jej podstawowym elementem jest etykieta RFID, która składa się z anteny, podłoża i struktury półprzewodnikowej. Przeszkodą w powszechnym zastosowaniu tej techniki jest cena jednostkowa etykiety. Według oceny analityków wprowadzenie elektroniki drukowanej umożliwi jej obniżenie. W ten sposób stanie się ona porównywalna z ceną kodu kreskowego. Zastosowanie technik drukowania i odpowiednich materiałów pozwoli na wydrukowanie kompletnej etykiety RFID, tj. anteny wraz ze strukturą półprzewodnikową. W niniejszym artykule opisano badania drukowanych anten etykiet do identyfikacji radiowej RFID. Zostały one wytworzone na elastycznych podłożach przy użyciu past srebrowych. Opisane eksperymenty stanowią podstawę do kontynuowania badań w zakresie drukowanych etykiet RFID.
EN
Economy based on knowledge requires faster and faster information process. One of the techniques which allows improving data transfer efficiency is radio frequency identification RFID. Its basic element is RFID tag consisted of antenna, substrate and chip. The main obstacle in its common using is its unit price. According to analytics opinion printed electronics makes possible to decrease it. In this way, it becomes comparable with a unit price of barcode. Printed electronics allows printing a complete RFID tag, i.e. an antenna with a chip. In this paper, investigations on printed antenna of RFID tags were decribed. They were made using flexible substrates and silver pastes. A quality of printed antennas were evaluated and its electrical parameters were measured. Experiments decribed in this paper are a basis for the next research in the range of printed RFID tags.
EN
A joint UHF/AE method for PD detection and identification in HV equipment was described in the paper. Authors presented an defect identification method on the basis of measured AE and UHF signal analysis. The result of investigation done on test transformer with paper-oil insulation was presented as an example of use of the elaborated method.
15
Content available remote Możliwości wykorzystania kontenerowego systemu rozpoznania Marynarki Wojennej
PL
W artykule przedstawiono warianty taktyczno-operacyjnego wykorzystania kontenerowego systemu rozpoznania elektronicznego pracującego w zakresach: radiolokacyjnym, radiowym UKF i w podczerwieni.
EN
The paper presented the variants of using the operational-tactical reconnaissance electronic container system which works in radar, radio FM, and infrared waveband.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.