EN
Purpose: The aim of the present study was to analyze the changes in the angular positions and lengths of the mandibular elevator muscles due to the displacement of bone segments after bilateral sagittal split osteotomy. Additionally, the impact of changes in mandibular geometry on the values of occlusal forces and mandibular condyle loading was considered. The combined geometric and force analysis makes a valuable contribution to the operating conditions of the system affected by the changes. Methods: The considerations were based on elementary principles of analytical geometry and the analysis was performed for two craniofacial geometries. Results: For the rotation of the proximal segment, the greatest differences in angular position concern the masseter muscle during roll rotation (11.7°). Significant changes in muscle length occurred during pitch rotation and amounted to 3.7 mm. Translation of the distal segment by 10 mm changed the angle of the pterygoid muscle by 30.2° in the coronal plane and 18.7° in the sagittal plane, simultaneously changing its direction to that of the opposite. Posterior translation (10 mm) caused an elongation of the muscle by 4.7 mm and anterior translation caused a shortening by 2.6 mm. For the mandible with elongated geometry, lower values of occlusion forces and increased reaction forces in the condyle were observed. Conclusions: The analysis revealed significant changes in the orientation and length of the masticatory muscles, and thus, their potential impact on the functioning conditions of the masticatory system.
EN
The aim of the work is to identify the lubrication conditions of the correct temporomandibular joint (TMJ) based on spatial modeling of joint structures, load simulations, reduced stresses, and resultant deformations in correlation with rheological parameters of synovial fluid. The material used in this study is the results of normal joint imaging performed using a standardized technique under occlusal conditions. Modeling and the simulation of contact, after the introduction of strength parameters of hard tissues, fibrous cartilage, and synovial fluid and the imposition of boundary conditions was carried out in the following program: Femap NE Nastran. Spatial simulation of contact between joint structures, virtual loading, and the visualization of what happens in the joint allows one to identify these structures in terms of tribology and strength. The transfer of loads in TMJ results from the geometric form of the supporting bone structures and joint surfaces, the distribution of the cartilage tissue building these surfaces, the geometry of the disc, and rheological parameters of the joint synovial fluid. In normal and loaded TMJ, differential displacement occurs in the joint cavity and cartilage structures, which stimulates the lubrication mechanism and optimize the use of synovial fluid properties. The joints are characterized by the absorption of maximum stresses reduced by bone structures. Load compensation and suspension is achieved by cartilage covering the joint surfaces and, to a large extent, by the joint disc and elastic-viscous response of a synovial fluid.
PL
Celem pracy jest identyfikacja warunków smarowania prawidłowego SSŻ na podstawie przestrzennego modelowania struktur stawowych, symulacji obciążeń, naprężeń zredukowanych i odkształceń wypadkowych w korelacji z parametrami reologicznymi cieczy synowialnej. Materiałem badań są wyniki obrazowania stawów prawidłowych wykonane w standaryzowanej technice w warunkach okluzji. Modelowanie i symulacje kontaktu, po wprowadzeniu parametrów wytrzymałościowych tkanek twardych, chrząstki włóknistej i cieczy synowialnej oraz nałożeniu warunków brzegowych, zrealizowano w programie Femap NE Nastran. Przestrzenna symulacja kontaktu struktur stawowych, wirtualne obciążanie i wizualizacja tego, co następuje w stawie, pozwala identyfikować te struktury w aspekcie tribologicznym i wytrzymałościowym. Przeniesienie obciążeń w SSŻ wynika z formy geometrycznej oporowych struktur kostnych i powierzchni stawowych, z rozkładu tkanki chrzęstnej budującej te powierzchnie, geometrii krążka oraz parametrów reologicznych mazi stawowej. W prawidłowym i obciążonym SSŻ pojawiają się w jamie stawowej oraz w strukturach chrzęstnych zróżnicowane przemieszczenia wypadkowe, które stymulują mechanizm smarowania i optymalizują wykorzystanie właściwości płynu synowialnego. Dla stawów charakterystyczne jest przejmowanie maksymalnych naprężeń zredukowanych przez struktury kostne. Kompensacja obciążenia i jego amortyzacja realizowana jest poprzez chrząstkę pokrywającą powierzchnie stawowe oraz w znacznym stopniu przez krążek stawowy i odpowiedź sprężysto-lepką cieczy synowialnej.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.