The paper proposes the use of auxiliary equipment in the low voltage network: an on-load tap changer and a static synchronous compensator (STATCOM) to improve the quality of energy supply to end users. As part of the research, a section of medium and low voltage power grid was modelled using Matlab & Simulink software, which was tested in three scenarios. The first scenario presents the operation of the power grid with the on-load tap changer installed in the transformer block. The second scenario uses the STATCOM for local reactive power compensation. Additionally, the third scenario is the combined work of the on-load tap-changer along with the STATCOM. According to the authors, the method discussed does not bring the expected results in the area of voltage quality improvement, indicating that further research is required, including tests with energy storage.
PL
W artykule zaproponowano zastosowanie pomocniczych urządzeń w sieci niskiego napięcia: podobciążeniowego przełącznika zaczepów oraz kompensatora mocy biernej (STATCOM) w celu poprawy jakości energii dla odbiorców końcowych. Zamodelowano fragment sieci elektroenergetycznej średniego i niskiego napięcia za pomocą oprogramowania Matlab & Simulink, który został poddany badaniu w ramach trzech scenariuszy. Pierwszy scenariusz prezentuje pracę sieci elektroenergetycznej z podobciążeniowym przełącznikiem zaczepów zainstalowanym w kadzi transformatora. Drugi scenariusz wykorzystuje STATCOM do lokalnej kompensacji mocy biernej. Natomiast trzeci scenariusz jest to jednoczesna praca podobciążeniowego przełącznika zaczepów wraz ze STATCOM. Zaprezentowany sposób według autorów nie przyniósł oczekiwanych rezultatów w zakresie poprawy jakości napięcia i wskazuje na dalszą potrzebę badawczą z wykorzystaniem magazynów energii.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The Static Var Compensator (SVC) and the Static Synchronous Compensator (STATCOM), as two components of Flexible AC Transmission System (FACTS) devices, play an important role in controlling the reactive power flow to the power network. Because of economic considerations, identifying the best location for installing the SVC and STATCOM is also important. The FACTS devices placement problem is commonly solved using heuristic optimization techniques which are diverse and have been the subject of ongoing enhancements. This paper presents a survey of the literature from the last decade that has focused on the various heuristic optimization techniques applied to determine optimal placement and sizing of the SVC and STATCOM.
PL
W artykule analizuje się optymalne usytuaowanie elementów SVC I STATCOM w systemie FACTS. Przedstawiono stan wiedzy wykorzystania do tego celu różnych heurystycznych metod optymalizacji.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.