Removal of suspended solids and microorganisms from an aerated lagoon effluent with a horizontal roughing filter (HRF) was investigated. The aerated lagoon receives Qom municipal wastewater. The HRF was operated at three filtration rates of 0.5, 1.0 and 1.5 m3/(m2·h) during four month operation period. The measured values of turbidity, TSS, COD, pH, temperature and flow rate of HRF at the former filtration rate were 79±12 NTU, 100±11 mg/dm3, 190±12 mg/dm3, 7±0.1 °C, 17±8 °C and 0.82 dm3/min, respectively. The differences between inlet and outlet values of pH and temperature were not significant (P > 0.05). Measures turbidity, TSS and COD in HRF final effluent were 15±13.7 NTU, 37±295 mg/dm3, 64±39.7 mg/dm3, respectively, which corresponds to 81.1%, 63% and 66.3% removal efficiencies, respectively. A decrease of removal efficiency was observed upon increasing filtration rates. The Spearman correlation coefficients between the head-loss and removal efficiencies ranged from 0.578 to 0.968 pointing to a direct relationship. Results of modeling approach revealed appropriate compliance between the values of the observed and predicted TSS for higher filtration rates.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
This paper considers the dependence of pressure fields on surfaces of rectangular prisms obtained from wind tunnel experiments on boundary layer characteristics. Six different variants of boundary layer flows were simulated in the wind tunnel. The qualitative coefficients of correlation Rs between the wind pressure coefficient Cp or its standard deviation σp and parameters describing boundary layer flows (wind speed profile, turbulence intensity profile, power spectral density) were estimated in order to determine how wind parameters influence surface pressure. Five rectangular prisms were placed in the wind tunnel. The following ratios of prism dimensions were adopted: D/B/H = 1:2:20 (R5); 1:2:10 (R3); 1:2:5 (R1); 1:4:20 (R4); 1:4:10 (R2).
PL
W artykule przedstawiono analizę zależności ciśnienia zmierzonego na powierzchniach obiektów prostopadłościennych w trakcie badań wykonanych w tunelu aerodynamicznym od parametrów opisujących strukturę wiatru w warstwie przyściennej. W pomiarach przyjęto sześć różnych wariantów struktury wiatru. Wyznaczono jakościowy współczynnik korelacji Rs między współczynnikiem średniego ciśnienia Cp lub jego odchylenia standardowego σp na powierzchni modeli, a parametrami określającymi strukturę wiatru w warstwie przyściennej (pionowym profilem średniej prędkości wiatru, pionowym profilem intensywności turbulencji, funkcją gęstości widmowej mocy). Celem analiz było określenie wpływu poszczególnych parametrów wiatru na ciśnienie powierzchniowe. Pomiary wykonano na pięciu modelach prostopadłościanów o następujących stosunkach wymiarów: D/B/H = 1:2:20 (R5), 1:2:10 (R3), 1:2:5 (R1), 1:4:20 (R4), 1:4:10 (R2).
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.