Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  Scott transformer
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
EN
Abstract This article presents investigations performed on a 25 kV AC system with a Scott transformer simulation model. The model includes an energy quality parameter calculation algorithm with consideration to the train timetable. The simulation results enable an analysis of the energy quality parameters at the point of connection of the traction substation to the supplying grid. The presented tool enables the simultaneous calculation of voltage unbalance and harmonic content. The article presents the results of the energy quality analysis at the substation connection point for the specific location. The simulation results of the energy quality parameters are appraised on the basis of standard EN 50160:2010. The tool may prove helpful in the process of designing electrification systems, especially in the choice of traction transformer and power electronics device mitigating an imbalance and harmonic impact.
PL
Artykuł przedstawia badania przeprowadzone z wykorzystaniem modelu symulacyjnego systemu zasilania prądu przemiennego 25 kV 50 Hz z transformatorem Scotta, uwzględniającym wszystkie czynniki jakości energii elektrycznej przy uwzględnieniu rozkładu jazdy pociągów. Wyniki badań pozwalają na kompleksową analizę parametrów jakości energii w punkcie przyłączenia podstacji trakcyjnej do systemu elektroenergetycznego przy uwzględnieniu rozkładu jazdy pociągów oraz rodzaju taboru. W porównaniu z innymi opublikowanymi pracami przedstawione narzędzie pozwala na określenie zarówno asymetrii napięciowej jak i harmonicznych napięcia w punkcie przyłączenia podstacji trakcyjnej. Narzędzie może być przydatne procesie projektowania układu zasilania, w szczególności doboru urządzenia symetryzującego na podstacji trakcyjnej dla danej lokalizacji tak, aby uzyskać spełnienie wymagań normatywnych.
PL
Niniejszy artykuł przedstawia wyniki badań wpływu autotransformatorowego systemu zasilania 2 x 25 kV z transformatorem Scotta na jakość energii elektrycznej w publicznej sieci zasilającej. Badania oparte były na laboratoryjnym modelu fizycznym autotransformatorowego systemu 2x25 kV. Model fizyczny składa się z modelu podstacji trakcyjnej z transformatorem Scotta, indukcyjnościami sieci trakcyjnej, szyn i dodatkowego zasilacza, autotransformatorów i 2 typów pociągów. Badania obejmują jednocześnie wszystkie czynniki mające wpływ na jakość energii elektrycznej, mianowicie asymetrię prądową, zawartość wyższych harmonicznych i zmiany mocy pobieranej.
EN
The paper presents investigation of the influence of the AC autotrans-former power supply system on the energy quality in public grid. The research includes construction of a laboratory model of AC autotransformer railway power supply system. The model consists of power substation with Scott transformer, overhead catenary system with the inductances of the contact wire, parallel feeder and running rails, autotransformers and two trains. The first one with the inverter-asynchronous drive and the second with the diode rectifier and DC motor drive. The influence of the AC autotransformer system on the public grid considering all types of the disturbing influence including voltage unbalance, voltage harmonic generation and power fluctuation in aggregated.
3
Content available remote Multilevel Power Converter Based on a Three Single-Phase Voltage Source Inverters
EN
In this paper it is proposed a new three-phase multilevel power conversion structure. This structure uses a three single-phase voltage source inverters and Scott transformer. The structure composed by the three single-phase voltage source inverters has two single-phase outputs. These outputs will connect to the Scott transformer. This transformer allows deriving two-phase voltage to a three-phase source. The proposed multilevel power conversion structure allows obtaining a five-level three-phase inverter. To control the proposed power converter it is used a sliding mode controller with a vectorial modulator. Several test results of the proposed converter structure with their control system are presented. From the obtained results it is possible to confirm the voltage multilevel waveforms and the effectiveness of the proposed control system technique.
PL
W artykule zaproponowano nową strukturę wielopoziomowego przekształcania energii elektrycznej. W strukturze tej użyto trzy jednofazowe falowniki napięcia oraz transformator Scotta. Struktura ta posiada dwa jednofazowe wyjścia. Wyjścia te są połączone z transformatorem Scotta. Transformator ten umożliwia zamianę napięć dwufazowych na napięcia trójfazowe. Proponowana struktura multipoziomowego przekształcania energii elektrycznej umożliwia otrzymanie trójfazowego, pięciopoziomowego falownika napięcia. W układzie sterowania wykorzystano sterowanie ślizgowe (sliding mode) z modulatorem wektorowym. Zaprezentowano kilka wyników badań proponowanej struktury z użyciem tego typu układu sterowania. Z otrzymanych wyników możliwe jest potwierdzenie uzyskania napięć wielopoziomowych oraz efektywności proponowanego układu sterowania.
EN
In this paper it is proposed a unity power factor isolated three-phase rectifier with buck-boost characteristics. This rectifier is based on the Scott transformer and only uses two single-phase buck-boost rectifiers. In this way only two switches are used. To achieve sinusoidal input current and high power factor, a fast and robust pulse width sliding mode modulation of the input current is proposed. An output voltage compensator is also used to establish the amplitude of the reference currents. Several results are presented in order to show the effectiveness of the proposed rectifier.
PL
W artykule przedstawiono izolowany prostownik trójfazowy o jednostkowym współczynniku mocy i charakterystyce typu Buck-boost. Prostownik ten powstał na bazie układu transformatora Scotta z zastosowaniem tylko dwóch jednofazowych prostowników Buck-boost. Tym sposobem ograniczono ilość użytych kluczy do dwóch. W celu osiągnięcia sinusoidalnego prądu wejściowego i wysokiej wartości współczynnika mocy, zaproponowano szybką i stabilną modulację szerokościową ze sterowaniem ślizgowym prądu wejściowego. Kompensator napięcia wyjściowego jest użyty w celu ustalenia amplitudy prądów referencyjnych. Wybrane rezultaty zaprezentowano w celu zobrazowania efektywności proponowanego prostownika.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.