Content available remote A Dynamic State Estimation Method Based on Mixed Measurements for Power System
EN
Dynamic State Estimation (DSE) techniques have the ability to foresee potential contingencies and security risks. Any improvement in its ability to estimate would definitely go a long way in reducing the security risks in the modern power system. One important factor affecting the quality of estimation is the measurement accuracy. Phasor Measurement Unit (PMU) has revolutionized the way state estimation is performed. The unique ability to measure the voltage and current phasors (magnitude and phase angle) with very high accuracy makes PMU extremely useful in modern Energy Management Systems (EMS). Due to the high price, technology level and communication capacity, the PMU can’t be equipped in all buses in the system nowadays. Therefore, this paper brings forward an improved method on dynamic state estimation that combines some buses measurements from PMU with measurements from SCADA. As Relevance Vector Machine (RVM) has a better performance on the regression, the state estimation algorithm is based on RVM in this article. Since the input data dimension is too large, pre-processing of data is needed. Autoencoder Network (Autoencoder) can be used for data dimensionality reduction. So this paper uses Autoencoder to reduce the data dimensionality, and then uses RVM to estimate the state of power system.
PL
W artykule przedstawiono metodę estymacji stanów dynamicznych w sieci elektroenergetycznej, wykorzystujący pomiary fazy i amplitudy napięcia i prądu oraz pomiary SCADA z poszczególnych punktów sieci. W algorytmie wykorzystano maszynę wektorów RVM. Ze względu na zbyt duży wymiar danych wejściowych, zastosowano pre-processing z wykorzystaniem sieci neuronowej auto-encoderowej.
EN
This paper presents a new hybrid method for the short-term load forecasting in electric power systems based on particle swarm optimization (PSO) and relevance vector machine (RVM). In this method, we firstly develop a type of kernel as the kernel function of the RVM model, and then its parameter is optimized by the PSO, finally the established RVM forecast mode is applied to short-term load forecasting in electric power systems in a city. The simulation results show the parameter of the wavelet kernel is well optimized using the PSO, and the acquired RVM model is more sparse and can obtain higher forecast accuracy compared with the RVM model with Gaussian kernel, so the proposed method is effective for forecasting the short-term load in electric power systems.
PL
W artykule zaprezentowano nową hybrydową metode krótkoterminowego prognozowania obciążeń sieci energetycznej bazująca na algorytmie mrówkowym PSO i narzędzia RVM (relevance vector machine). W pierwszym etapie wyznaczane jest falkowe jądro (kernel) jako RVM co znacznie poprawia skuteczność algorytmu PSO.
PL
W artykule zaprezentowano zaawansowane metody diagnostyki przepustów transformatorowych. Przedstawiono wyniki modelowania rozkładu temperatury wewnątrz rdzeni przepustów oraz analizę wpływu zestarzenia na odpowiedź dielektryczną modelu przepustu typu RIP, na podstawie analizy charakterystyk FDS i RVM. Starzenie termiczne modelu przepustu RIP powoduje przesunięcie charakterystyk FDS w stronę wyższych częstotliwości, natomiast produkty rozkładu powodują pojawienie się dodatkowej relaksacji widoczniej w zakresie wysokoczęstotliwościowym.
EN
The paper presents advanced diagnostic methods of transformer bushings. There are given results of temperature distribution modeling inside bushings’ cores and the analysis of ageing influence on dielectric response of RIP type bushing model, based on the FDS and RVM characteristics. Thermal ageing of RIP bushing model causes the shift of FDS curves into higher frequencies, whereas deterioration products lead to appearance of additional relaxation in high frequency range.
PL
Omówiono zasadę szacowania zawilgocenia izolacji papierowo-olejowej transformatorów metodą skojarzonego pomiaru "RVM-PDC". Stwierdzono, że skojarzony pomiar "RVM-PDC" poprawia jakość szacowania, zwłaszcza w transformatorach o niejednorodnej morfologii izolacji. Przedstawiono przemysłowy miernik realizujący pomiar w trybie "RVM-PDC". Metoda ta, po uwzględnieniu badań olejowych, daje możliwość identyfikacji osadów na części aktywnej transformatorów. Zaprezentowano przykłady identyfikacji osadów na obiektach rzeczywistych.
EN
The principle of moisture contents assessment in transformer paper-oil insulation by means of the joint RVM-PDC measurement is described. Such a measurement is based on using the first two steps of the RVM method for additional determining of the insulation setup time characteristics of charging and discharging currents. The difference between these currents with capacitance of windings allow calculating cellulose conductivity which is the function of tempera-ture and moisture contents. In this way it is possible to assess the water contents on the basis of two various electrical phenomena: polarization and conductivity. It was found that the joint RVM-PDC measurement increased the quality of assessment, especially for transformers of non-homogenous morphology of insulation. This method, together with additional consideration of oil tests, allows sludge identification on the active part of transformers. The principle of identification is based on finding large differences of the moisture level assessment from RVM and PDC tests. The sludge presence on the insulation surface can be treated as equivalent of additional moisture contents. In such a case the RVM test gives too high results of water contents in cellulose. On the contrary, the PDC test is not significantly influenced by this effect. The more sludge on the insulation, the more visible this phenomenon is. The insulation ageing also results in physicochemical changes of oil properties, especially in the losses coefficient tg?, acidity, resistivity and furans contents (2-FAL). The analysis of results obtained from insulation electric tests and oil physicochemical tests allows determining if the insulation is with unbalanced water contents in the paper and oil or with sludge presence. Some examples of sludge identification performed on real objects are shown. The internal inspection of the transformer confirmed positive diagnosis on sludge presence.
PL
Przedstawiono doświadczenia w szacowaniu zawilgocenia izolacji papierowo-olejowej transformatorów z zaawansowanymi procesami starzenia. Stwierdzono, że skojarzony pomiar „RVM+PDC” poprawia jakość szacowania, zwłaszcza w transformatorach o niejednorodnej morfologii izolacji. Dla zawartości wody w celulozie większej od 3% w analizie zawilgocenia konieczne jest uwzględnienie wyników badań oleju. Pomiar „RVM+PDC” po uwzględnieniu badań olejowych daje możliwość identyfikacji osadów na części aktywnej transformatorów.
EN
Experiences in moisture contents assessment in paper-oil insulation of transformers with advanced ageing processes have been presented. It was found that joint measurement RVM+PDC increases quality of assessment, especially for transformers with non-homogenous morphology of insulation. For water contents in cellulose higher that 3% it is necessary to take into consideration for analysis results of oil tests. The measurement RVM+PDC after considering oil tests allows to identify deposits on the active part of transformers.
6
Content available remote Procesy relaksacyjne w modelu granicy faz "olej-preszpan"
PL
W artykule zaprezentowano pomiary nieliniowej relaksacji zachodzącej w modelu kanałów olejowych transformatora. Pomiary wykonano dla różnych temperatur metodami RVM, PDC i FDS oraz systemem skojarzonym FDS+PDC. Czas głównej relaksacji występującej w modelu zmienia się eksponencjalnie, a wyliczone na tej podstawie wartości energii aktywacji są znacznie mniejsze dla pomiarów wykonywanych przy stałym polu elektrycznym, niż przy zmiennym. Występujący efekt nieliniowości został potwierdzony pomiarem za pomocą systemu DIRANA.
EN
The paper presents measurements of nonlinear relaxation in model of oil gaps of transformer. Measurements have been conducted in two temperatures using RVM, PDC and FDS methods and also joint FDS+PDC system. The time of model's main relaxation changes in exponential way and values of activacion energy calculated on this basis are significantly lower for measurements taken at DC electric field, than at AC. Nonlinear effect has been confirmed with DIRANA system.
EN
Dielectric measurements and diagnostic methods are established procedures to evaluate moisture as an ageing indicator in commonly used oil-paper insulations of power transformers. Both the measurements themselves as well as the analysis of collected data contain several uncertainties and sources of error. This investigation discusses the sources of error and gives a further insight to the influences of transformer insulation design (geometry), insulation temperature, moisture equilibrium in oil and paper and other aspects regarding practical measurements. The dominating impact on dielectric analysis is related to the insulation temperature rather than insulation geometry. Limits and influences on linear modelling of multilayer insulations by equivalent circuits are described too. The investigation includes all the common dielectric diagnostic methods for oil-paper insulations: Recovery Voltage Method (RVM), Polarisation and Depolarisation Currents (PDC) and Frequency Domain Spectroscopy (FDS).
EN
Recently diagnostic techniques using measurements in time and low frequency domain are very intensive developed. There are used various methods (RVM, FDS, PDC), which allow to evaluate the moisture content of paper insulation or its degradation degree. However up to now in the most cases the interpretation of measurement results is ambiguous. The paper presents field measurement results of different operating time power transformers. The measurement of power transformers were taken using three methods: RVM, FDS, PDC. Analysis of dielectric dispersion in time and frequency domain was also presented. Then the analysis results were compared. It was obtained, that the calculated relaxation time of primary relaxation structure for both measurements in time and frequency domain was the same.