The subject of this paper is an assessment of the accuracy of a solution based on the linear theory of elasticity describing the interaction of a cylindrical reinforced concrete tank with the subsoil. The subsoil was modelled in the form of an elastic half-space and Winkler springs. The behaviour of the shell structure of the RC cylindrical tank, and particularly of the ground slab interacting with the subsoil, depends largely on the distribution of the reactions on the foundation surface. An analysis of this structure with the shell fixed in a circular ground slab was carried out taking into consideration the elastic half-space model using the Gorbunov-Posadov approach and, for comparison, the two-parameter Winkler model. Although the results for both subsoil models proved to be divergent, the conclusions that follow the accuracy assessment of a solution based on the theory of elasticity are fairly important for engineering practice.
PL
Obserwacje stanu technicznego żelbetowych komór silosów cylindrycznych (także w układach zblokowanych) wskazują, że ściany takich silosów podlegają często intensywnym zarysowaniem. W obiektach po wieloletnim okresie eksploatacji obserwuje się pionowe rysy nadmiernej szerokości i wysokości nawet kilkunastu metrów. W przypadku przechowywania materiałów sypkich podatnych na zawilgocenie, stan taki uniemożliwia praktycznie eksploatację silosu. Problem kontroli zarysowania ścian żelbetowych silosów w ujęciu norm europejskich wymaga odrębnego postępowania, gdyż z reguły nie jest możliwe zastosowanie procedur uproszczonych. Niezbędna jest wnikliwa analiza statyczna ustroju uwzględniająca, w ujęciu Eurokodu 1-4 złożone układy obciążeń, ustalenie wymagań co do szczelności żelbetowej ściany wg Eurokodu 2--3 oraz przeprowadzenie obliczeniowej kontroli szerokości rys zgodnie z Eurokodem 2.
EN
The paper discusses the design principles concerning computational cracking control in RC cylindrical silos. The procedures should be based on general method given in PN-EN 1992-1-1, taking into account tightness classification given in PN-EN 1992-3, on the basis of structural analysis elaborated for axi symmetrical and path loads due to silo wall pressures.
PL
W artykule przedstawiono model MES wykonany w programie DIANA 3D i 2D do analizy rozwoju naprężeń termicznych w młodym betonie. Przedstawiono przykład ściany cylindrycznego zbiornika żelbetowego zrealizowanego podczas rozbudowy oczyszczalni ścieków. Model uwzględnia rozwój ciepła hydratacji i wpływ temperatury słonecznej powietrza na rozwój niejednorodnego pola temperatury. Zastosowano sprężysto-lepki model materiału. Przedstawiono rozwój efektywnej wytrzymałości betonu na rozciąganie, koniecznej do uwzględnienia przy analizie zarysowania powłoki w młodym wieku betonu.
EN
. In the paper it was presented FEM model which has been made in program DIANA 3D and 2D to an analysis of the development of a thermal stresses at early age concrete. It was presented an example of the cylindrical RC tank wall which was realized during the extension of the sewage treatment plant. The influence of the heat of the hydration and solar temperature of the air on the development of the non-uniform temperature area are included in the proposed model. Viscoelastic material was used in the calculation. The development of the effective tensile strength of concrete which is necessary to perform the crack analysis at early age concrete is allso presented.
PL
W niniejszym artykule przeanalizowano rozwój naprężeń termicznych w segmencie ściany żelbetowej wykonanej pomiędzy istniejącymi segmentami ściany zbiornika.
EN
In this article was presented an approximate analysis of the development of a thermal stress in the wall of the cylindrical RC tank which realized during the extension of the sewage treatment plant Krakow-Plaszow. In the analysed wall appeared four through cracks three days after removal of formwork of the width equal to 0.25 mm. However, later appeared numerous surface cracks of the width equal to 0.125 mm. The calculation took into account the influence of the solar temperature of the air on the development of the non-uniform temperature area (Fourier's equation). The development of the stress calculated with taking into account the momentary Young's modulus, the momentary creep function (according to Breugel) and the moment of removal of formwork.
PL
W pracy przedstawiono analizę stanu zarysowań żelbetowych ścian baterii dołów warzelnianych, poddanych działaniu obciążeń statycznych i pozastatycznych. W trakcie eksploatacji dołów warzelnianych, wykonanych jako cztery zblokowane zbiorniki o konstrukcji żelbetowej, stwierdzono wystąpienie przecieków przez pionowe mkrozarysowania ścian oraz w miejscu połączenia ścian podłużnych z dnem. W wyniku przeprowadzonych analiz wykazano, że elementy konstrukcyjne przejmowały bezpiecznie działające obciążenia statyczne, natomiast obciążenie temperaturą (gorąca woda) spowodowało nadmierne wytężenie zewnętrznych ścian zbiornika.
EN
The paper presents the analysis of scratching state of RC walls in boiling pits' conslruction. Structure was made as four tanks building and founded 2,90 m below ground level. Overall dimensions were I5,30x20,40><3.30 m. During exploitation the walls showed leaking symptoms through the micro-scratches and in wali and bottom joints. It vas proved that constructional elements of tank would take safely static loads but thermal loads would cause excessive effort of outer walls of tank.