Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  Q factor
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Diagnostics of turbine blades, based on estimation of frequency response function
EN
The aim of the study is to propose a diagnostics method based on blade’s vibration model in frequency domain. Amplitude spectrum A(ω) and phase spectrum φ(ω) have been experimentally identified which define transfer function G(jω) = P(ω) + jQ(ω) and their real P(ω) and imaginary Q(ω) parts. Transfer function G(jω) and resulting frequency, amplitude, phase characteristics and real P(ω) and imaginary Q(ω) parts are parts of blade’s diagnostics model. Changes in those characteristics are directly related to changes in the technical condition of the blades. It has been noticed that small changes in the technical condition cause large changes in frequency characteristics, which proves their usefulness in the diagnosis process.
PL
Celem badania jest zaproponowanie metody diagnostycznej opartej na modelu drgań łopatek w dziedzinie częstotliwości. Zidentyfikowano eksperymentalnie widma ampli-tudowe A(ω) i fazowe φ(ω), które definiują transmitancję operatorową G(jω) = P(ω) + jQ(ω) oraz jej rzeczywiste P(ω) oraz urojone Q(ω) części. Transmitancja operatorowa G(jω) i wynikająca z niej częstotliwość, amplituda, charakterystyka fazowa oraz rzeczywiste P(ω) i urojone Q(ω) części są częściami modelu diagnostycznego łopatki. Zmiany w tych charakterystykach są bezpośrednio związane ze zmianami w stanie technicznym łopatek. Zauważono, że małe zmiany w stanie technicznym powodują duże zmiany w charakterystykach częstotliwościowych, co świadczy o ich przydatności w procesie diagnostycznym.
EN
This paper reports on the development of an oven with a special purpose electronic board and specialist materials such as basalt fiber and nichrome. It is designed for optical resonators which are temperature controlled during their annealing process to increase their quality factor for the purpose of photonics applications.
3
Content available remote 10 Gbps optical line using EDFA for long distance lines
EN
The aim of this article is to demonstrate change in the BER (Bit Error Rate) and Q-factor in long distance lines. Nowadays it is not possible to create fully optical communication systems without software tools to simulate real optical networks under the given circumstances. There have been two 10 Gbps optical line topologies created: one without EDFA (Erbium Doped Fibre Amplifier) of up to 115 km and another using EDFA on a long distance line up to 3200 km. The article shows the BER worsening with the distance increasing and also the need for the link amplifier.
PL
Celem niniejszego artykułu jest przedstawienie zmian w BER (Bit Error Rate) oraz współczynnika Q na dużych odległościach. Obecnie nie jest możliwe stworzenie w pełni optycznych systemów komunikacyjnych bez użycia narzędzi programowych do symulacji rzeczywistych sieci optycznych w danych okolicznościach. Utworzono dwie 10 Gbps optyczne topologie liniowe: jedna bez EDFA (Erb z domieszką włókien Amplifier) maksymalnie do 115 km, a druga z użyciem EDFA na duże odległości do 3200 km. W artykule przedstawiono BER pogarszającą się wraz z rosnącą odległością.
EN
Seismic wave attenuation has strong, negative effect on the seismic data resolution. The high influence of this phenomenon was observed during realization of seismic survey "Duża Wólka 3D" (Geofizyka Kraków S.A. 2010a). The resolution of recorded seismic data was very low due to high attenuation caused by the Lower Triassic Buntsandstein sandstones. In consequence, interpretation of the thin-layered Zechstein formation is ambiguous. The aim of this paper is to present the multi-stage algorithm for the purpose of minimizing the attenuation effect, hence increasing the resolution of the seismic data. In order to achieve this, the inverse Q filtering process was used. The Q factor (quality factor) was estimated from the vertical seismic profiling data (Geofizyka Kraków S.A. 2010c). To verify the effectiveness of inverse Q filtering, seismic modelling was performed. Results received from seismic modelling gave basis for application the inverse Q filtering on real data. For this operation the seismic time profile inline 112 was chosen from the seismic data set "Duża Wólka 3D". Application of inverse Q filtering significantly increased the seismic resolution, which enabled the interpretation of the Zechstein formation with more accuracy.
EN
Parameterized wide-band geometry dependent SPICE models for oil-chip planar spiral inductors are developed in the paper. Model descriptions are presented in the form of PSpice model and in schematic view. The models are realized in the Cadence Capture and Cadence PSpice environment. The developed computer models can be used For adequate computer modeling and simulation of RF circuits. The geometry dependence of the model parameters allows geometry optimization and design automation of spiral inductors. The simulation results are compared to the measurement data for the model verification demonstrating the validity of the computer models.
6
Content available remote Examination and Development of a Radio Frequency Inductor
EN
Nowadays, inductors can be found in almost every electrical and electronic product. These key components are needed to store electrical energy, select frequencies, and protect againist overvoltage and overcurrent. In the case of the inductors, which usually work in the range of radio frequency, the one of the most important attributes is the quality factor. The aim of the project is to increase the Q-factor of an RF SMT inductor and to favour the industrial research and development about inductors by using the finite element method.
PL
W wielu dziedzinach współczesnej technologii elektrycznej i elektronicznej można znaleźć induktory. Są one niezbędne w gromadzeniu elektrycznej energii, w wyborze częstotliwości, a także w ochronie przepięciowej i przetęzeniowej. W przypadku induktorów, pracujących zwykle z częstotliwością radiową, istotnym ich parametrem jest współczynnik jakości (quality factor). Celem tej pracy jest wskazanie metody poprawy tego współczynnika.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.