Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  Poincaré map
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In this study, a three degrees of freedom nonlinear air cushion vehicle (ACV) model is introduced to examine the dynamic behavior of the heave and pitch responses in addition to the cushion pressure of the ACV in both time and frequency domains. The model is based on the compressible flow Bernoulli’s equation and the thermodynamics nonlinear isentropic relations along with the Newton second law of translation and rotation. In this study, the dynamical investigation was based on a numerical simulation using the stiff ODE solvers of the Matlab software. The chaotic investigations of the proposed model are provided using the Fast Fourier Transform (FFT), the Poincaré maps, and the regression analysis. Three control design parameters are investigated for the chaotic studies. These parameters are: ACV mass (M), the mass flow rate entering the cushion volume (in), and the ACV base radius (r). Chaos behavior was observed for heave, and pitch responses as well as the cushion pressure.
EN
This paper presents a study on ferroresonance occurring in a high voltage 400 kV transmission grid due to energization of power transformer under no-load conditions. The system scenarios analyzed in the present paper are considered as critical for development and modernization plans as currently announced by the national grid operator in Poland. The PSCAD simulation model was developed and applied for several study cases of a system with double-circuit arrangement of a transmission line. It is shown that the ferroresonant oscillations can be initiated by two-phase switching operation of a line circuit breaker. The impact of the double-circuit length on the ferroresonance mode and severity is demonstrated with the use of the Poincaré map analysis and Short Time Fourier Transform. It is demonstrated that the length of the transmission line that is mutually coupled in the double-circuit arrangement has a significant impact on the ferroresonance occurrence and on its mode. As the ferroresonance can pose severe threat to the power system components due to the severe overvoltage and overcurrent oscillations, the analysis presented in this paper demonstrates the necessity of the ferroresonance analyses for any re-designed transmission system.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.