N,N’-bis(2,4-dimethoxybenzylidene)ethylenediamine was synthesized and used as a membrane carrier to create a novel poly(vinyl chloride) membrane potentiometric sensor that is selective especially for Fe3+ ions. The super-Nernstian slope of the projected sensor was 19.5 mV per decade over a concentration range of 7.3•10-8–1•10-1 M having detection limit at 7.3•10-8 M. The sensor displayed a linear potential response for the detection of Fe3+ ions in about 30 seconds, and it had a lifespan of no less than 9 weeks without lacking any potential divergence. The selected sensor showed high selectivity in water solutions in relation to Fe3+ ions, even in the presence of other metal cations in the pH range of 3.6–10.
PL
Przedmiotem badań był potencjometryczny czujnik do selektywnego oznaczania jonów Fe3+ oparty na membranie wykonanej z poli(chlorku winylu) i N,N’-bis(2,4-dimetoksybenzylideno)etylenodiaminy. Nachylenie super-nernstowskie (ang. super-Nernstian slop) badanego czujnika wynosiło 9,5 mV na dekadę w zakresie stężeń 7,3•10-8–1•10-1 M z limitem detekcji 7.3•10-8 M. Czujnik wykazywał w obecności jonów Fe3+ liniową odpowiedź przez około 30 s, a jego czas życia bez rozbieżności potencjałów wynosił nie mniej niż 9 tygodni. Wybrany czujnik wykazywał w roztworach wodnych wysoką selektywność w stosunku do jonów Fe3+ nawet w obecności innych kationów metali w zakresie pH 3,6–10.
EN
The potential creating properties of a group of acidic chelating compounds are presented. The studies have been carried out by the constructing of new ion-selective electrodes based on PVC membranes doped with the studied compounds, and determining the basic analytical parameters of the electrodes. The usefulness of eight out of nine investigated compounds in the preparation of the membrane phase electrodes selective for cobalt, zinc and cadmium has been shown. It has been also found that the acidic properties of ionophore have an essential influence on the analytical parameters of the constructed electrodes. The response mechanism of the obtained electrodes has been investigated by simultaneous spectrophotometric-potentiometric measurement of membranes used in electrodes. It has been found that during the conditioning of electrode, a complex of active substance with primary ion is formed in the membrane phase, then the membrane composition is established and remains unchanged in the next measurements.
3
Content available remote Lekkie konstrukcje łukowe z drewna klejonego pokryte membraną PCV
PL
W artykule przedstawiono jedno z wielu zastosowań konstrukcyjnego drewna klejonego warstwowo – lekkie konstrukcje w postaci łukowych zadaszeń kortów tenisowych pokrytych membraną PCV. Drewno to najbardziej naturalny materiał budowlany, w pełni odnawialny surowiec, pochłaniający niskie ilości energii przy produkcji elementów pochodnych oraz łatwo poddający się recyklingowi. Z drugiej strony sport i zdrowy tryb życia. Idealne połączenie. Nowoczesne sposoby produkcji i obróbki drewna klejonego pozwalają kształtować praktycznie nieograniczone formy architektoniczne, co umożliwia ich stosowanie we wszelkich obiektach sportowych.
EN
The article presents one of many applications of structural glued laminated timber, that is light structures in the form of arched roofs of tennis courts covered with a PVC membrane. Wood is the most natural building material that is fully renewable, uses low amounts of energy when producing derivatives, as well as is easily recyclable. There’s also the issue of sport and a healthy lifestyle. Modern methods of producing and processing glued laminated timber make it possible to shape various architectural forms, which allows their use in all sports facilities.
5
Content available remote Pokrycie dachu z folii PVC zniszczone przez grad
PL
W wyniku opadu gradu w trakcie majowej burzy w 2014 r. nastąpiła perforacja pokrycia z membrany PVC na dachu sześcioletniej hali przemysłowej oraz budynku socjalno-technicznego i administracyjnego. Zalanie hali po uszkodzeniu pokrycia było wynikiem błędnego zaprojektowania połączenia blach T55 z obudową ścian zewnętrznych i z płatwiami. Małe pochylenie połaci dachowej uniemożliwiło zmianę pokrycia z membrany PVC na blaszane.
EN
PVC roof membrane covering the six-year old industrial building, social and technical building as well as office building as a result of heavy spring hailstorm in May 2014 was perforated. Flooding industrial hall after damage of roofing resulted from incorrect design of connection between steel sheet T55 and purlin as well as external fittings. Small slope of roofing disabled change the PVC membrane on the new cover steel sheet.
EN
Novel polymeric membrane (PME) and coated graphite (CGE) silver-selective electrodes based on a calix[4]resorcareneoctamethyl ester has been prepared. The electrodes revealed Nemstian behaviour over a wide Ag+ion concentration range (1.0 x 10'5-1.0 * 10 ' mol L"' for PME and 1.0 * 1.0-10(-7) x 10(-1) mol L(-1) for CGE) with very low detection limits (4.7 x K)(-6) mol L(-1) for PME and 8.5 x 10(-8) mol L(-1) for CGE). They occurred to be very selective towards Ag+ even in the presence of other numerous cations. Their responses were independent of pH within the range of 4-9. The electrodes can be used for at least 3 months without any considerable potential deviations. They served as indicator electrodes in poten-tiometric titration of silver ion.
PL
Spreparowano nowe, selektywne w stosunku do srebra elektrody z polimerową membraną (PME) zawierające ester kaliks[4]rezorkarenooktametylowy. W jednym rozwiązaniu konstrukcyjnym matrycę PCV nakładano na grafit. Elektrody spełniają prawo Nersta w szerokim zakresie stężenia jonów Ag+(l,O x 10(-5)-l,0x 10(-1) 'mol L(-1) w przypadku PME i 1,0 x 10(-7)-1,0 x 10(-1) w przypadku CGE) przy bardzo niskiej granicy wykrywalności (4,7 x l 0(-6) mol L(-1) w przypadku PME oraz 8,5 x l 0(-8) mol L(-1) w przypadku CGE). Wykazują bardzo dobrą selektywność w stosunku do jonów srebra nawet w obecności wielu innych kationów. Ich odpowiedzi nie zależą od wartości pH w granicach 4-9. Elektrody mogą być używane co najmniej przez 3 miesiące bez widocznych zmian potencjału. Stosowano je jako wskaźnik w potencjometrycznym miareczkowaniu jonów srebra.
EN
A lead (II) ion-selective poly(vinyl chloride) membrane electrode containing 2,2'-dithiodi-benzoic acid as a carrier was prepared. The electrode exhibits a Nernstian response for lead(II) cations over a wide Pb2+ concentration range (5.0 x 10(-6) x 10(-2) mol L(-1) with a slope of 29.9 š 0.3 mV decade(-1). Designed electrode exhibits a fast (time shorter than 10 s) and stable potential response for at least 3 months. Its selectivity to Pb2+ in the presence of alkali, alkaline earth and some transition and heavy metal ions is satisfactory in the pH range of 4-6.5. The studied sensor served as an indicator electrode in the potentiometric titration of lead ions, and also for determination of anions such as sulfides, chromałeś and carbonates.
PL
Spreparowano elektrodę jonoselektywną zawierającą kwas 2,2'-ditiodibenzoesowy w membranie z polichlorku winylu. Otrzymano odpowiedź nernstowską w stosunku do Pb2+ w zakresie stężeń 5 x 10(-6)-1 x 10(-2) mol (-1). Elektroda miała czas odpowiedzi poniżej l O s i mogła być używana przynajmniej przez miesiąc. Selektywność wobec Pb(2+) w obecności metali alkalicznych i ziem rzadkich oraz niektórych metali ciężkich i przejściowych była dobra. Przedział pH pracy elektrody określono jako 4-6.5. Opracowaną elektrodę użyto w potencjometrycznym miareczkowaniu Pb2+ oraz do oznaczania siarczków, chromianów i węglanów.
EN
A new PVC mebrane electrode for iodide ions based on a recently synthesized salen-Mn9II) complex as membrane carrier was prepared. The electrode exhibits a Nernstian slope of 59.0=+0.4 mV per decade for 1- over a wide concentration range (1.0 x 10-1 --.4x 10-5M). It has a relatively fast response time of about 20 s and can be used for at least three months without any divergence in potential. The proposed sensor shows a fairly good discriminating ability towards 1- ion in comparison to other common anions. The electrode can be used in the pH range 3.5-8.5. It was used as an indicator electrode in potentiometric titration of iodide ion.