Content available remote Power system small signal stability enhancement using fuzzy based STATCOM
EN
This paper describes how fuzzy based STATCOM was used to improve the small signal stability of Tis Abay II electric power generation. Tis Abay II is a power generation facility in Ethiopia, located in the Bahir Dar Amhara region, with a nominal apparent power generating capacity of 40MVA. The oscillating nature of a rotating machine, the imbalance of load and generation, the presence of exciter and compensator, and the occurrence of faults all contribute to the disruption on an interconnected power network. The frequency oscillation of the existing plant was evaluated in the absence of a power system stabilizer (PSS) and an adaptive fuzzy logic controller (AFLC). The proposed system network configuration was used to fine-tune the mathematical analysis of synchronous machine data and model. The proposed model incorporates SMIB system modeling and an AFLC. MATLAB Simulink was used to simulate the effect of the PSS and AFLC on rotor speed, angle, and electrical torque. The proposed system's power system dynamic stability was improved using a PSS and a fuzzy logic-based STATCOM. According to the simulation results, FLCbased STATCOM is best suited for improving the dynamic stability of Tis Abay II power generation.
PL
W tym artykule opisano, w jaki sposób STATCOM oparty na rozmyciu został wykorzystany do poprawy stabilności małych sygnałów w wytwarzaniu energii elektrycznej Tis Abay II. Tis Abay II to zakład energetyczny w Etiopii, położony w regionie Bahir Dar Amhara, o nominalnej mocy pozornej wytwarzania 40MVA. Oscylacyjny charakter maszyny wirującej, niezrównoważenie obciążenia i generacji, obecność wzbudnicy i kompensatora oraz występowanie usterek przyczyniają się do zakłóceń w połączonej sieci energetycznej. Oscylacje częstotliwości istniejącej elektrowni zostały ocenione przy braku stabilizatora systemu elektroenergetycznego (PSS) i adaptacyjnego sterownika logiki rozmytej (AFLC). Zaproponowana konfiguracja sieci systemu została wykorzystana do dostrojenia analizy matematycznej danych i modelu maszyny synchronicznej. Proponowany model obejmuje modelowanie systemu SMIB i AFLC. MATLAB Simulink wykorzystano do symulacji wpływu PSS i AFLC na prędkość wirnika, kąt i moment elektryczny. Stabilność dynamiczna systemu elektroenergetycznego proponowanego systemu została poprawiona za pomocą PSS i STATCOM opartego na logice rozmytej. Zgodnie z wynikami symulacji, STATCOM oparty na FLC najlepiej nadaje się do poprawy dynamicznej stabilności generacji Tis Abay II.
2
Content available remote Robust control of power system stabilizer using sliding mode approach
EN
This paper proposes a method of sliding mode control (SMC) approach for excitation control in a single generator-infinite bus power system. Conventional power system stabilizer (C-PSS) design becomes a complicated problem in presence of internal and external disturbances to the excitation of a power system. Improving the stability of the power system has become a priority objective. The aim of this work is to ensure maximum damping of the electromechanical oscillations of the Single Machine Infinity Bus System (SMIB) by the power stabilizers based on the sliding mode control technique. The effectiveness of the proposed approach is demonstrated through computer simulations on two different cases of operating conditions. The performance of the proposed approach is evaluated in terms of damping power system oscillations. The obtained results show the high performance of the proposed controller to improve the stability of the power system compared to the C-PSS and found to be impressive.
PL
W artykule zaproponowano metodę sterowania trybem ślizgowym (SMC) do sterowania wzbudzeniem w pojedynczym generatorowonieskończonym systemie zasilania szyny. Konstrukcja konwencjonalnego stabilizatora systemu elektroenergetycznego (C-PSS) staje się skomplikowanym problemem w obecności wewnętrznych i zewnętrznych zakłóceń wzbudzenia systemu elektroenergetycznego. Poprawa stabilności systemu elektroenergetycznego stała się celem priorytetowym. Celem pracy jest zapewnienie maksymalnego tłumienia oscylacji elektromechanicznych systemu SMIB (Single Machine Infinity Bus System) przez stabilizatory mocy oparte na technice sterowania ślizgowego. Skuteczność proponowanego podejścia demonstrowana jest poprzez symulacje komputerowe w dwóch różnych przypadkach warunków pracy. Skuteczność proponowanego podejścia oceniana jest pod kątem tłumienia oscylacji systemu elektroenergetycznego. Uzyskane wyniki wskazują na wysoką wydajność proponowanego sterownika w celu poprawy stabilności systemu elektroenergetycznego w porównaniu z C-PSS i okazały się imponujące.
EN
Hybrid white light-emitting devices (HWLEDs) were fabricated using FTO/PEDOT: PSS/PbS/Alq3/Ni system and synthesized by phase separation process. In the present study, the multiple excitons generation in lead sulfide (PbS) NCs, which is characteristic of PbS NCs, was used to induce an effective and regulated energy transfer to an HWLED. The HWLED consisted of three layers successively deposited on FTO glass substrate; the first layer consisted of poly (3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT: PSS) blended with polymethyl methacrylate (PMMA) organic polymer in the 1:1 ratio, while the second layer consisted of PbS NCs. Finally, above the layer of the PbS NCs, Tris (8-hydroxyquinoline) aluminum (Alq3) layer was deposited. The white light was generated with quite a good efficiency due to the confinement effect that makes the energy gap greater. The characteristics of the current-voltage (I-V) indicate acceptable conditions for the generation of white light by multiple excitons. It was found that the emission levels able to produce white luminescence, classified based on the coordinate system of chromaticity (CIE 1931), are x = 0.31, y = 0.33 while the correlated color temperature (CCT) is about 6250 K. The HWLEDs made from PbS NCs with hole injection from the organic polymer (PEDOT: PSS with PMMA), and electron injection from organic molecules (Alq3) are capable of white light generation.
EN
An affine nonlinear autoregressive moving average (NARMA) model is derived from the neural network (NN) based general NARMA model in this paper, by using Taylor series expansion. The predictive error of this affine NARMA model will be quite acceptable, at least for the control purpose, if the amplitude of control input is properly limited. Therefore, an adaptive control scheme based on this model is proposed and applied to the design of adaptive power system stabilizer (APSS) since the amplitude of PSS output is usually well limited. The feature of this control scheme is that the control input can be online analytically obtained. Thus, comparing to the traditional NN based APSS (TAPSS), the affine NARMA model based APSS (AAPSS) does not need the training of a NN as neuro-controller, which may be a troublesome and time consuming step during the design. Moreover, the AAPSS can generally perform better than the TAPSS. Simulation studies on a single machine infinite bus system and a multi-machine system show that the AAPSSs can consistently well perform to damp electromechanical oscillations in the systems over a wide range of operating conditions.
PL
Przedstawiono wyniki badań wpływu stężenia oraz masy cząsteczkowej poli(soli sodowej siarczanu styrenu) (PSS) na wielkość cząstek wodnej dyspersji poli(hydroksyalkanolanów) (PHA). Stwierdzono, że im mniejsza jest masa cząsteczkowa zastosowanego PSS, tym mniejsza jest wielkość cząstek PHA w dyspersji. Spośród analizowanych stężeń najmniejszą wielkość cząstek dyspersji uzyskano przy zastosowaniu PSS o stężeniu 0,25% mas. Otrzymana dyspersja była stabilna po 7 dniach przechowywania. Nie stwierdzono jednak poprawy właściwości barierowych względem pary wodnej papieru powlekanego tą dyspersją. Analiza SEM wykazała na powierzchni papieru obecność miejscowych skupisk PHA zamiast jednolitego filmu.
EN
Soln. of a com. poly(hydroxyalkanoate) in CH₂Cl₂ was dispersed in an aq. soln. of poly(Na styrene sulfonate) (PSS) to produce a stable emulsion for packagings. The size of dispersion particles and emulsion stability decreased with decreasing mol. mass of PSS. No improvement in barrier properties of coated papers against water vapour was obsd.
EN
In this paper the design an optimal PSS-PID controller for single machine connected to an infinite bus (SMIB). We presented a novel application of particle swarm optimization (PSO) for the optimal tuning of the new PSS-PID controller. The proposed approach has superior features, including easy implementation, stable convergence characteristic and good computational efficiency. The synchronous generator is modeled and the PSO algorithm is implemented in Simulink of Matlab. The obtained results have proved that (PSO) are a powerful tools for optimizing the PSS parameters, and more robustness of the system IEEE SMIB.
PL
W analizie i planowaniu strategicznym nieraz zachodzi potrzeba dokonania wyboru, który poparty byłby logicznymi uzasadnieniem. Proces dokonywania wyboru jest trudny, ponieważ zawiera wiele zmiennych zarówno mierzalnych, jak i niemierzalnych. Nieraz należy dokonać wyboru spośród parunastu, bądź parudziesięciu i więcej wariantów. Trudno jest określić, które warianty są najlepsze i dlaczego. W artykule zaprezentowano metodę SWOT-AHP-PSS, która winna wspomóc proces decyzyjny planowania strategicznego. Nowatorstwo metody SWOT-AHP-PSS polega na nowym połączeniu metod już znanych. Metoda SWOT-AHP-PSS pozwala określić wielkość prawdopodobieństwa sukcesu każdego z poszczególnych n-wariantów, a także pozwala zidentyfikować najważniejsze czynniki wpływające na wielkość wskaźnika PSS. Metoda ta może znaleźć zastosowanie zarówno w prostym, jak i bardzo złożonym procesie decyzyjnym.
EN
In the article has been shown a new method SWOT-AHP-PSS, which can be used in the process of strategic planning. Methods SWOT, AHP, PSS have been known for many years, but their connection, presented in the article, is new. The combination SWOT-AHP-PSS first time has been used in PhD dissertation of Wiktor-Sułkowska A. The method SWOT-AHP-PSS allows to set the success probability (PSS) of each of individual n-variants. The method also allows to identify the most important factors, which affect to the size of the PSS indicator. This method can be used in both simple and difficult decisionmaking process.
EN
Textile-based capacitors have been made from polyethylene dioxythiophene, polystyrene sulphonate (PEDOT:PSS) as the electrolyte and pure stainless steel filament yarns as the electrodes. The capacitor is well integrated into the textile structure, small in size and of light weight. Although they experience a self-discharge, the reliability of the PEDOT:PSS capacitors has been investigated by repeating up to 14 cycles of charging and discharging. Initially, the voltage output turns out to be higher with increasing number of cycles. However, after the fifth cycle, degradation of the cell starts occurring and a decreasing behaviour in the voltage output is observed. One can roughly say that these capacitors could be used up to 10–15 cycles.
PL
Kondensatory tekstylne wytwarza się z mieszaniny poli(3,4-dioksyetylenotiofenu) z polistyrenem sulfonowanym (PEDOT: PSS), pełniącej rolę elektrolitu oraz włókien ciągłych z czystej stali nierdzewnej, pełniących funkcję elektrod. Kondensatory tego typu są dobrze zintegrowane ze strukturą tkaniny, są lekkie i mają niewielkie rozmiary. Chociaż kondensatory PEDOT:PSS ulegają samorozładowaniu, przeprowadzono badania ich niezawodności powtarzając 14 cykli ładowania i rozładowywania Początkowo napięcie wyjściowe zwiększało się wraz ze wzrostem liczby cykli. Jednakże po piątym cyklu, dochodziło do degradacji ogniwa i obserwowano zmniejszanie się napięcia wyjściowego. Można orientacyjnie powiedzieć, że omawiane kondensatory nadają się do użytku przez maksymalnie 10–15 cykli.
9
Content available remote Coordinated design of UPFC and PSS to improve power system stability
EN
A modified particle swarm optimization is proposed and used for coordinated designing of the power system stabilizer and unified power flow controller as a damping controller in the multi-machine power system. For evaluation of the effectiveness and robustness of the proposed controllers, their performances have been tested on a weakly connected power system subjected to different disturbances. The results of these studies show that the proposed coordinated controllers have an excellent capability in damping power system inter-area oscillations and enhance greatly the dynamic stability of the power system.
PL
W artykule opisano metodę projektowania struktury sterowania układem elektrycznym wielomaszynowym, gwarantującej stabilność pracy i jednostkowy współczynnik mocy. W metodzie wykorzystano zmodyfikowaną optymalizację rojem cząstek. Analizy skuteczności i odporności polegała na poddaniu zakłóceniom systemu przy połączeniu słabym. Wyniki badań potwierdzają skuteczność proponowanego rozwiązania.