Aiming at the problem of DC voltage control deviation and instability caused by a large-scale renewable energy access VSC–MTDC system, this paper combines voltage margin control and droop control. A strategy for controlling collaborative optimization in a sparsely distributed communication network has been proposed. Firstly, the distributed modeling of the system is carried out by combining MAS technology with small signal modeling. Then, a distributed model predictive controller is designed for a single droop control converter station. On this basis, a distributed cooperative optimization control strategy is proposed. According to the DC voltage deviation, the system adopts different control methods to control the receiving converter station. Finally, based on PSCAD/EMTDC and MATLAB co-simulation platforms, a six-terminal flexible HVDC system is built to verify the effectiveness of the control strategy under different conditions such as input power fluctuation, any converter station out of operation and system communication failure.
2
Content available remote Modelowanie układu zabezpieczeń elektroenergetycznych dużego bloku wytwórczego
PL
W artykule przedstawiono zagadnienia dotyczące automatyki zabezpieczeniowej bloków wytwórczych. Opisano zestaw zabezpieczeń dużego bloku wytwórczego oraz stany awaryjne pracy bloku, na które te zabezpieczenia wpływają. Opisano zamodelowany w programie PSCAD/EMTDC blok wytwórczy wraz z układem zabezpieczeń elektroenergetycznych. Zamodelowany układ odzwierciedla stanowisko laboratoryjne. Przedstawiono przykładowe wyniki badań zamodelowanego zabezpieczenia od utraty wzbudzenia generatora.
EN
Issues related to power protection of power generating units are described in the submitted paper. A set of power protection system for a large power generating unit is described, as well as emergency states of the unit's operation which are affected by these protections. A power generating unit modeled in the PSCAD/EMTDC program was described together with the power protection system. The modeled system represents a laboratory stand. Examples of tests of the modeled protection against loss of field are presented.
PL
W artykule opisano jeden z programów do symulacji zjawisk dynamicznych występujących w systemie elektroenergetycznym. Program o nazwie PSCAD/EMTDC jest powszechnie używany do modelowania fragmentów systemu elektroenergetycznego i zjawisk w nich występujących. Przedstawiono dostępne w programie modele linii napowietrznych, które mogą zostać wykorzystane do modelowania takich sytuacji jak stany łączeniowe (załączenia, wyłączenia) linii, zwarcia w linii. W programie linie napowietrzne można zamodelować ręcznie za pomocą elementów pasywnych typu R, L, C, z wykorzystaniem gotowych czwórników typu PI, za pomocą gotowych modeli typu Bergeron Model, Frequency Dependent (Mode) Model, Frequency Dependent (Phase) Model. Pokazano przykładowy sposób zamodelowania linii WN 110 kV z wykorzystaniem słupów kratowych typu B2 za pomocą modelu typu Frequency Dependent (Phase) Model.
EN
The article describes one of the programs for the simulation of dynamic phenomena occurring in the power system. The program called PSCAD/EMTDC is commonly used to model the parts of the power system and phenomena occurring in them. The models of the overhead lines that can be used for modelling situations such as switching states of the line, short-circuit line have been presented. Overhead lines can be manually modelled using passive R, L, C elements by using prepared PI section elements, using prepared Bergeron Model, Frequency Dependent (Mode) Model, Frequency Dependent (Phase) Model. It was shown how to model a high-voltage line 110 kV with the use of type B2 towers by the Frequency Dependent (Phase) Model.
EN
This paper proposes a novel dc-link voltage balancing scheme for cascaded H-bridge multilevel APF by using level-shift PWM (LS-PWM) with carrier swapping technique. The mathematical derivation and the control strategy are presented. The dc-link voltage of individual H-bridge is feed-forwarded to minimize the dc-link ripples across the dc-link capacitors. Finally, extensive simulation results obtained from PSCAD/EMTDC are provided to verify the validity and effectiveness of the proposed scheme.
PL
W artykule zaproponowano układ sterowania zapewniający równy rozkład napięć kondensatorów w wielopoziomowym filtrze aktywnym o topologii kaskadowej zawierającej mostki typu H. Metoda wykorzystuje modulację poprzez komparację z przesunięciem poziomów fal nośnych. Podano odpowiednie zależności analityczne uzasadniające podstawy teoretyczne zaproponowanej metody, która zapewnia również minimalizacje tętnień napięć kondensatorów. Podano wyniki badań symulacyjnych modelu opracowanego w oparciu o język PSCAD/EMTDC przy uwzględnieniu niejednorodności wybranych parametrów układu i braku symetrii.
EN
Faults in the power system are major cause of voltage sag. Voltage sag in the power system due to fault can be symmetrical or unsymmetrical. For sensitive loads it is necessary to estimate how many times in year the voltage at their terminal will experience sag to avoid tripping of operation. Several stochastic methods for estimation of number of sags are developed in recent years. In different methods of sag prediction there is need to do lengthy programming or calculations. Here PSCAD/EMTDC software package is used to estimate number of sag with uniform distribution of faults along the lines.
PL
Uszkodzenia linii kablowych stanowią znaczące zagrożenie dla zachowania ciągłości dostarczania odbiorcom energii elektrycznej. Stąd wszelkie działania mające na celu wyeliminowanie tego zagrożenia należą do nieodzownych przedsięwzięć. W artykule przedstawiono możliwości modelowania oraz symulacji lokalizacji uszkodzeń w kablowych liniach elektroenergetycznych metodą impulsową za pomocą programu PSCAD/EMTDC do celów dydaktyczno-naukowych. Przeprowadzono porównanie wyników symulacji numerycznej lokalizacji uszkodzeń z wynikami uzyskanymi za pomocą lokalizatora FOG-211 na modelu fizycznym linii kablowej.