Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  PMP
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper involves the formulation of a non - linear optimal control model framework depicting fascioliasis disease transmission in the population of domestic ruminants only. The optimal control analysis is studied to investigate the effect of time-dependent preventive controls of treatment of worms in infected animals c1(t), hygiene compliance of separation/distancing of susceptible animals from infected environment sources c2(t) and sanitation of the environment c3(t). The positivity and boundedness of the model solutions are investigated, while the optimal control model solutions are shown to exist. The optimal control model is characterized using the Pontryagins Maximum Principle (PMP), which leads to the derivation of the optimality system. The optimal control model is solved using the forward - backward Runge - Kutta fourth order (RK4) sweep scheme via computational software MATLAB, where simulations reveal that each control is capable of reducing fascioliasis infection, but the combined implementation of the three control strategies are more effective in stemming the high rate of prevalence of the disease in the domestic animal population. Further simulations show that the preventive control profiles of c1(t), c2(t) and c3(t) are sustained for few months before reducing gradually to zero in the final time of 12 months.
PL
Fascjoloza jest ostrą pasożytniczą chorobą zakaźną u ludzi i domowych przeżuwaczy, zwłaszcza w krajach o słabym przestrzeganiu higieny, braku leczenia z robaczycy u zakażonych zwierząt i utrzymywaniu warunków sanitarnych środowiska. Niniejsza praca dotyczy sformułowania nieliniowego modelu optymalnego sterowania, ilustrująca przenoszenie fascjolozy przy założeniu ograniczenia do populacji domowych przeżuwaczy. Optymalne sterowanie jest badane w celu ustalenia wpływu zależnych od czasu prewencyjnych kontroli leczenia robaków u zakażonych zwierząt c1(t), przestrzegania higieny oddzielania/oddalania podatnych na zakażenie zwierząt od istniejących źródeł środowiskowych c2(t) i sanitacja środowiska c3(t). Zbadano dodatniość i ograniczoność rozwiązań modelowych oraz wykazano istnienie optymalnych sterowań w modelu kontrolnym. Optymalne sterowanie scharakteryzowano za pomocą zasady maksimum Pontryagina, która prowadzi do wyprowadzenia systemu warunków optymalności. Sterowania optymalne są uzyskane przy użyciu schematu czwartego rzędu Runge-Kutta. Obliczenia wykonano za pomocą oprogramowania MATLAB. Symulacje pokazują, że każde sterowanie jest w stanie zmniejszyć infekcję fascjolozą, ale połączone użycie trzech strategii sterowania jest bardziej skuteczne gdy mamy do czynienia z wysokim wskaźnikiem występowania choroby w populacji zwierząt domowych. Dalsze symulacje pokazują, że profile sterowań prewencyjnej c1(t), c2(t) i c3(t) utrzymują się przez kilka miesięcy, po czym stopniowo zmniejszają się do zera w końcowym okresie 12 miesięcy.
EN
The solid particle number method was introduced in the European Union (EU) light-duty legislation for diesel vehicles to ensure the installation of the best-available technology for particles (i.e., wall-flow diesel particulate filters) without the uncertainties of the volatile nucleation mode and without the need of large investment for purchasing the equipment. Later it was extended to gasoline vehicles with direct injection engines, heavy-duty engines (both compression ignition and positive ignitions) and non-road mobile machinery engines. Real Driving Emissions (RDE) testing on the road with Portable Emissions Measurement Systems (PEMS) for particle number (and NOx) during type approval and in-service conformity testing was recently (in 2017) introduced for light-duty vehicles, and is under discussion for heavy-duty vehicles in-service conformity testing. This paper will summarize the existing legislation regarding solid particle number and discuss the on-going activities at EU level. The main focus at the moment is on improving the calibration procedures, and extending the lower detection size below 23 nm with interlaboratory exercises. In parallel, discussions are on-going to introduce testing at low ambient temperature, regeneration emissions in the light-duty regulation, a particle limit for other technologies such as gasoline port-fuel injection vehicles, and the feasibility of particle measurements to L-category vehicles (mopeds, motorcycles, tricycles and minicars). A short overview of periodical technical inspection investigations and the situation regarding non-exhaust traffic related sources with special focus on brakes and tyres will be described.
PL
Przemysł papierniczy podlega bezpośrednim wpływom globalnych megatrendów. Z jednej strony, niektóre z nich, takie jak rozwój e-commerce, szybkie tempo życia, wzrost jednoosobowych gospodarstw domowych, proces starzenia się społeczeństwa, a także zwiększona wrażliwość na zrównoważony rozwój (trendy proekologiczne), napędzają wzrost branży papierniczej. Stwierdzenia te sprawdzają się zwłaszcza w sektorach tissue oraz opakowań tekturowych. Z drugiej strony, w konsekwencji rozwoju mediów cyfrowych, zaobserwować można drastyczny, globalny spadek popytu na papiery gazetowe.
EN
This paper presents an attempt to estimate the value of Probable Maximum Precipitation (PMP) over the Kielce Upland for one-day and multi-day intervals. Statistical methods were employed in the calculations. Precipitation data were obtained from 23 gauging stations. A regional frequency factor km (from Hershfield’s formula) was calculated for each station based on a series of maximum annual precipitation totals from 1961 to 2006. The calculated PMP values range from 120.7 mm to 228.4 mm (within the 1-day precipitation group), from 140.7 mm to 266.3 mm (2-day group), from 158.9 mm to 294.1 mm (3-day group), and from 175.2 mm to 294.8 mm (4-day group). These values became reference values used to show the spatial distribution of PMP throughout the Kielce Upland region.
5
Content available remote Particulate and soot measurement in view to EURO V
EN
In case of heavy duty diesel engines there is 80% reduction from EURO III particulate emission level to EURO IV particulate emission level. In case of passenger diesel cars a reduction of 90% of the particulate emission limit is required when changing from EURO IV to EURO V. This means a huge research effort for engine R&D. New exhaust after treatment systems like DPF (Diesel Particle Filter) or SCR (Selective Catalytic Reduction) are demanding special specifications ofthe emission test instrumentation. Low emission measuring values require a high sensitivity as well as a high repeatability of the emission test instruments. Due to appearance of transient testing real-time measurements are needed with fast response times. Low particulate emission test applications and in use emission testing for R&D but also legislation trends are described below.
PL
Zaprezentowano zagadnienia związane z systemami radiowego dostępu abonenckiego. Przedstawiono nie tylko wymagania stawiane tego typu systemom, ale również realizowane przez nie usługi. Szczególną uwagę poświęcono systemom umożliwiającym realizację usług multimedialnych.Przedstawiono stan normalizacji w zakresie tych systemów oraz przykładzie ich rozwiązania.
EN
Basic concept of radio local loop system (RLL) is presented. The requirements according to the ETSI specification, architecture of the system and typical services are discussed. The particular attention is focused on PMP and LMDS systems. For these radio local loop systems the standardisation status and examples of solutions are described.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.