Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 9

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  PET-CT
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Progress and perspectives in total body PET systems instrumentation
EN
Total body positron emission tomography (PET) systems are being developed by different groups worldwide. These systems have potential to change the number of applications in which molecular imaging is used. The change from a short axial field of view (FOV) to a longer one is however associated with a linear increase in the cost of these systems. This may limit their application to a small number of centers (capable of obtaining sufficient research funding). Therefore it remains interesting to see if lower cost systems can be developed and bring total body PET to the clinic for an acceptable budget. The wider availability of this low cost system can also enable more researchers to further optimize and explore the full potential of total body PET.
2
Content available remote FEM-based MRI deformation algorithm for breast deformation analysis
EN
Breast tissue deformation has recently gained interest in various medical applications. The recovery of large deformations caused by gravity or compression loads and image registration is a non-trivial task. The most effective tool for breast cancer visualisation is Magnetic Resonance Imaging (MRI). However, for MRI scans the patient is in a prone position with the breast placed in signal enhancement coils, while other procedures, i.e. surgery, PET-CT (Positron Emission Tomography fused with Computer Tomography) are performed with the patient in a supine position. The need therefore arises to estimate the large breast deformations caused by natural body movement during examinations or surgery. There is no doubt that a patient's breast in both positions has a different shape and that this influences relationships between intra-breast structures. In this work, we present the fundamentals of a method for transformation of breast images based on Finite Element Methods (FEMs). This 2D model uses the simplest constitutive tissue description, which makes it easily applicable and fast. According to the Jaccard Index, the average accuracy obtained is 95%, the lowest is 87%, and the highest is 99%. The model parameter set is proposed for six different breast size classes, covering the whole population. The algorithm provides reliable breast images in a supine position in a few simple steps.
3
Content available Zastosowanie technik medycyny nuklearnej w ortopedii
PL
Główną zaletą obrazowania z zastosowaniem technik medycyny nuklearnej jest możliwość uchwycenia zmian funkcjonalnych, które pojawiają się przed zmianami anatomicznymi. W związku z tym wykorzystanie technik medycyny nuklearnej umożliwia wczesne wykrycie m.in. chorób układu mięśniowo-szkieletowego.
EN
The major advantage of nuclear medicine imaging is that functional changes appear before an anatomical change. Therefore, imaging in nuclear medicine enables the early detection of diseases of the musculoskeletal system.
4
Content available PET/CT w diagnostyce guzów mózgu
PL
Wczesna diagnostyka zmian guzów zlokalizowanych w ośrodkowym układzie nerwowym jest bardzo istotna. Podstawowymi badaniami obrazowymi w diagnostyce guzów mózgu są tomografia komputerowa (TK) oraz rezonans magnetyczny (MR). Pomimo wykorzystania tych metod wykrywanie wznowy miejscowej oraz odróżnienie jej od zmian wywołanych zastosowanym leczeniem jest bardzo trudne. Obrazowanie z wykorzystaniem technik medycyny nuklearnej stanowi uzupełnienie do podstawowych metod obrazowania guzów ośrodkowego układu nerwowego (OUN). Po wprowadzeniu 18F-fluorodeoxyglukozy (18F-FDG) do diagnostyki i wykazaniu wartości diagnostycznej z użyciem tego znacznika, obrazowanie w neurologii stało się jednym z ważniejszych obszarów jego wykorzystania. Ze względu na wysoki fizjologiczny metabolizm glukozy w tkance mózgowej i związany z tym wysoki wychwyt FDG w obrębie mózgowia, wykrycie i zróżnicowanie zmian nowotworowych w ośrodkowym układzie nerwowym jest utrudnione. Wykorzystanie innych radiofarmaceutyków i obrazowania techniką pozytonowej tomografii emisyjnej PET (Positron Emission Tomography) pozwala na wykrycie hipoksji, dostarcza informacji na temat przemian biochemicznych aminokwasów lub proliferacji komórkowej. Dzięki temu zwiększa się czułość w diagnostyce guzów mózgu oraz poprawia ocena odpowiedzi na leczenie czy wczesnym wykrywaniu wznowy. W niniejszej pracy przedstawiono metody obrazowania guzów ośrodkowego układu nerwowego z użyciem techniki PET/CT.
EN
Early diagnostic is critical in central nervous system tumors. Primary imaging modalities in brain tumors are computed tomography (CT) and magnetic resonance (MR). Despite use of these methods recurrence detection and differentiation between tumor and post-therapeutic changes is still challenging. Nuclear medicine modalities provide additional information unavailable in CT or MRI imaging. After FDG introduction the diagnostic value of this radiotracer was quickly proven and ever since positron emission tomography (PET) has become one of most important tools in brain tumor management. Due to the high physiologic activity of 18F-FDG in healthy brain tissue, it is difficult to differentiate the lesions within the brain. Positron emission tomography using other markers visualizing hypoxia, aminoacids metabolism or proliferation increases the sensitivity of brain tumor diagnostics and follow-up of the treated area to detect early recurrence. The paper presents methods for imaging central nervous system tumors using the PET/CT.
5
Content available remote Wizualizacja multimodalnych danych PET-CT
PL
W pracy omówiono podstawowe metody obrazowania wnętrza ciała człowieka oraz zaprezentowano przykłady wizualizacji multimodalnych danych medycznych pochodzących z aparatu PET-CT. Omówiono użyte algorytmy wizualizacji danych, ich wady i zalety oraz zaprezentowano przykłady użycia opracowanej hybrydowej metody prezentacji multimodalnych danych medycznych.
EN
In the paper the basic methods of imaging the interior of the human body and examples of visualization of multimodal medical data from PET-CT are presented. A new hybrid method based on surface rendering and color mapping of PET-CT visualization is shown. Qualitative results confirm effectiveness of proposed method.
PL
Technika PET jest obecnie podstawową metodą obrazowania molekularnego. Jest stosowana w diagnostyce, określeniu stopnia zaawansowania choroby oraz w monitorowaniu leczenia. Do podstawowych rozwiązań, które jednoznacznie przyczyniły się do rozwoju techniki PET należą wprowadzenie iteracyjnych metod rekonstrukcji obrazów, zastosowanie nowych typów kryształów scyntylacyjnych, wprowadzenie metody PET-CT, opracowanie metody time of flight, a obecnie zastosowanie metody PET-MRI. Zrozumienie zasad techniki PET, jej zalet, a przede wszystkim ograniczeń, jest niezbędne nie tylko dla właściwej interpretacji ostatecznego wyniku przez lekarza, ale również dla optymalizacji parametrów skanowania i oceny źródeł artefaktów przez fizyka/ inżyniera medycznego.
EN
At present, PET is a basic method of molecular imaging. It is applied in diagnostics, for determining the degree of the progress of illness and in monitoring the treatment. To basic answers which explicitly contributed to the development of PET belong introduction of iterative methods for reconstruction of images, applying new types of scintillators, implementing the hybrid PET-CT scanners, developing the method time of flight, and at present, application of PETMRI. Understanding principles of the technique, its limitations and advantages, is essential not only for appropriate interpretation of the final result by the doctor, but especially for the optimization parameters of scanning and the evaluation of sources of artifacts by the medical physics/engineer.
EN
The increasing numbers of PET studies for routine diagnosis creates a real hazard to radiation workers. The aim of this study is to estimate the annual whole-body and finger radiation dose to technologists working with 18F-FDG in a PET center with high patient potential. In our PET center, the number of PET imaging has increased almost to 5000 studies per year. Our standard dose for tumor imaging is 518 MBq of 18F-FDG. Five technologists performing all steps of 18F-FDG imaging (5 patients per technologist in a day) were officially involved round the week for handling and injecting 18F-FDG to patients. Whole-body and finger dose measurements with TLDs were performed for two different time periods: i) before shielding precautions during the first 6 months (without a shielding for sterile syringe and without a lead container for shielded syringe) and ii) after shielding precautions during the next 6 months (with a shielding for sterile syringe and with a lead container for shielded syringe). The average annual whole-body radiation dose for one technologist before shielding precautions was 7.82 mSv and after shielding precautions was 5.76 mSv. On the other hand, while the average annual finger radiation doses for one technologist before shielding precautions were 210.36 and 293.72 mSv for the left and right hand, after shielding precautions were they 158.16 and 217.58 mSv for the left and right hand, respectively. According to our results, if one technologist performs the whole-body PET imaging of 5 patients per day, the annual radiation dose to this technologist will not exceed the recommended limits by ICRP.
8
Content available remote PET-CT w Warszawie
9
Content available remote Tomografia pozytonowa w Warszawie
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.