PL
W artykule omówiono referaty przygotowane na sesję CIGRE 2022 w ramach Komitetu Studiów C2 Sterowanie i praca systemów elektroenergetycznych. Referaty i dyskusje prowadzone podczas sesji skupiały się na zagadnieniach gotowości pomieszczenia dyspozytorskiego do współczesnych wyzwań, a także na kwestiach strategii planowania operacyjnego, jej metodyce oraz narzędziach wspierających.
EN
Discussed are papers prepared for the CIGRE 2022 session as part of the Study Committee C2 System Operation and Control. Presented papers and discussions that took place during the session focused on the issues concerning preparedness of the control room for present challenges as well as on the ssues of operational planning strategy, its methodology and supporting tools.
2
Content available remote Odpowiedź dielektryczna papieru aramidowego impregnowanego estrem syntetycznym
PL
Niniejsza publikacja zawiera badania odpowiedzi dielektrycznej papieru aramidowego (Nomex) impregnowanego estrem syntetycznym (Midel 7131) w różnej temperaturze i zawilgoceniu. Procesy relaksacyjne badano metodami FDS (Frequency Domain Spectroscopy) oraz PDC (Polarization Depolarization Current). Do wykonania pomiarów użyto systemu DIRANA OMICRON oraz miernika Keithley 6517A. Do prezentacji i analizy wyników pomiarów wykorzystano program Origin v.8.0 oraz WinFit firmy Novocontrol. Do wyznaczenia podstawowych parametrów funkcji relaksacyjnych zastosowano uogólnione równanie Havriliaka-Negamiego oraz zależność Jonschera LFD.
EN
This publication deals with the recognition of the influence of temperature and moisture on dielectric relaxation parameters of insulation based on aramid paper impregnated with synthetic ester (Midel 7131). Relaxation processes were investigated by FDS (Frequency Domain Spectroscopy) and PDC (Polarization Depolarization Current). DIRANA OMICRON and Keithley 6517A system was used for the measurements, while Origin v.8.0 and Novocontrol WinFit were used to analyze measurement results. The generalized Havriliak-Negami and Jonscher LFD equation was used to determine the relaxation functions.
PL
Artykuł dotyczy badań właściwości dielektrycznych nowoczesnych wysokonapięciowych izolacji stało-ciekłych. W publikacji tej zaprezentowano pomiary metodą PDC (Polarization Depolarization Current) impregnowanego estrem syntetycznym Midel 7131 papieru aramidowego Nomex typ 410. Analizę jakościową procesów relaksacyjnych przeprowadzono za pomocą zależności Jonschera LFD. Na podstawie czasów charakterystycznych Tk oszacowano energię aktywacji niezbędną do inicjacji procesu relaksacji długoczasowej.
EN
The article concerns the research of dielectric properties of modern high voltage insulation paper-oil. This publication presents the method of measurement PDC (Polarization Depolarization Current)) impregnated aramid paper with a synthetic ester. The identification of the relaxation processes were performed using Jonscher LFD model. On the basis of the characteristic time Tk estimated activation energy LFD process.
4
Content available remote Dielectric response of oil impregnated Nomex in frequency and time domain
EN
Nomex has been introduced to electrotechnical industry, mainly as high voltage insulating material, used for example in power transformers. The aim of this paper is to identify the influence of moisture on dielectric relaxation of solid-liquid insulation consisting of Nomex impregnated with transformer oil. From practical measurements a series of FDS (Frequency Domain Spectroscopy) and PDC (Polarization Depolarization Current) characteristics were obtained for Nomex-oil insulating system.
PL
Nomex znalazł ważne zastosowanie w branży elektrotechnicznej, głównie jako wysokonapięciowy materiał izolacyjny stosowany w transformatorach energetycznych. Niniejsza publikacja dotyczy rozpoznania wpływu zawilgocenia na relaksację dielektryczną stało-ciekłej izolacji złożonej z Nomexu impregnowanego olejem transformatorowym na podstawie pomiarów metodą spektroskopii dielektrycznej FDS (Frequency Domain Spectroscopy) oraz rejestracji pradów polaryzacji i depolaryzacji PDC (Polarization Depolarization Current).
EN
This article presents the results of laboratory tests on samples of aramid- synthetic ester Midel insulation using the method of PDC (Polarization and Depolarization Current). Furthermore, a methodology of preparing samples with varying degrees of moisture and the analysis of the results of measurements on the basis of family characteristics determined on measurements of depolarization current.
PL
W artykule zaprezentowano pomiary PDC (Polarization Depolarization Current). impregnowanego olejem transformatorowym Nomexu o różnym zawilgoceniu. Analizę jakościową procesów relaksacyjnych przeprowadzono za pomocą aproksymacji pradów polaryzacji funkcją Jonschera LFD. Badania wykazały, że szacowanie zawilgocenia Nomexu za pomocą metody PDC może być utrudnione dla zawartości wody 1 3,5%. Następnie wyniki badań zweryfikowano z wynikami pomiaru metodą FDS (Frequency Domain Spectroscopy).
EN
Nomex has been introduced to electrotechnical industry mainly as a high voltage insulating material, used for example in power transformers. The aim of this paper is to identify the influence of moisture on dielectric relaxation of solid-liquid insulation consisting of Nomex impregnated with transformer oil. To perform such research, there was constructed a special measurement set-up with steel electrodes 20x20 cm large. A sheet of Nomex 410, 0.76 mm thick, was placed between these electrodes. The required values of moisture level were achieved by drying Nomex at 150°C in a laboratory vacuum chamber or through moisturization in a Feutron climate chamber at the relative air humidity 90% and the temperature 24°C. The moisture level was estimated on the basis of measurements of weight changes. Relaxation processes were measured with the PDC method (Polarization Depolarization Current). The research showed that assessment of the moisture content with the PDC method can be difficult for the values from the range 1-3%. The experimental results were verified with FDS (Frequency Domain Spectroscopy) measurements. The analysis of the relaxation process of oil impregnated Nomex showed that: a) water content in Nomex results in significant increase in dielectric losses, which seems to be caused by water particles, b) in the moisture range 1-3% dielectric response of Nomex is practically the same and does not depend on the moisture level. The same effect was observed for both relaxation process and conductivity, c) for the water content above 3-3,5% there is a rapid increase in the conductivity and dielectric losses. It is probably due to the exceeding percolation threshold of water particles gathered between aramid fibres.
7
Content available remote Wpływ osadów na procesy elektryczne w izolacji papierowo-olejowej
PL
W artykule zaprezentowano pomiary zjawisk relaksacji warstw osadów na papierze w modelu kanału olejowego transformatora metodą PDC (Polarization Depolarization Current). Pomiary wykonano w temperaturze 22 0C dla różnej grubości osadów naniesionych na celulozę. Analiza charakterystyk PDC wykazała występowanie dwóch zjawisk relaksacyjnych. Określono dla nich wartości stałych czasowych. Wpływ osadów na procesy relaksacyjne zmierzono również za pomocą metody FDS (Frequency Domain Spectroscopy) dla modelu przepustu OIP.
EN
The paper presents measurements of relaxation phenomena of sludge layer on the paper in the model of transformer oil gap with PDC (Polarization Depolarization Current). The measurements have been taken at 22 0C for various thickness of sludge on a cellulose. The analysis of PDC characteristics showed presence of two relaxation phenomena. For both values of time constants have been estimated. The influence of Sludge on the paper surface on the relaxation phenomena has been measured also with FDS (Frequency Domain Spectroscopy) method for a model of OIP bushing.
EN
The article describes the application for synchrophasors monitoring from Phasor Measurement Units (PMU) and Phasor Data Concentrators (PDC). The application is designed for user-friendly visualization of synchrophasors from PMU and PDC. The application meets the requirements of IEEE Std C37.118-2005, which represents the standard in this field.
PL
Omówiono zasadę szacowania zawilgocenia izolacji papierowo-olejowej transformatorów metodą skojarzonego pomiaru "RVM-PDC". Stwierdzono, że skojarzony pomiar "RVM-PDC" poprawia jakość szacowania, zwłaszcza w transformatorach o niejednorodnej morfologii izolacji. Przedstawiono przemysłowy miernik realizujący pomiar w trybie "RVM-PDC". Metoda ta, po uwzględnieniu badań olejowych, daje możliwość identyfikacji osadów na części aktywnej transformatorów. Zaprezentowano przykłady identyfikacji osadów na obiektach rzeczywistych.
EN
The principle of moisture contents assessment in transformer paper-oil insulation by means of the joint RVM-PDC measurement is described. Such a measurement is based on using the first two steps of the RVM method for additional determining of the insulation setup time characteristics of charging and discharging currents. The difference between these currents with capacitance of windings allow calculating cellulose conductivity which is the function of tempera-ture and moisture contents. In this way it is possible to assess the water contents on the basis of two various electrical phenomena: polarization and conductivity. It was found that the joint RVM-PDC measurement increased the quality of assessment, especially for transformers of non-homogenous morphology of insulation. This method, together with additional consideration of oil tests, allows sludge identification on the active part of transformers. The principle of identification is based on finding large differences of the moisture level assessment from RVM and PDC tests. The sludge presence on the insulation surface can be treated as equivalent of additional moisture contents. In such a case the RVM test gives too high results of water contents in cellulose. On the contrary, the PDC test is not significantly influenced by this effect. The more sludge on the insulation, the more visible this phenomenon is. The insulation ageing also results in physicochemical changes of oil properties, especially in the losses coefficient tg?, acidity, resistivity and furans contents (2-FAL). The analysis of results obtained from insulation electric tests and oil physicochemical tests allows determining if the insulation is with unbalanced water contents in the paper and oil or with sludge presence. Some examples of sludge identification performed on real objects are shown. The internal inspection of the transformer confirmed positive diagnosis on sludge presence.
10
PL
Przedstawiono doświadczenia w szacowaniu zawilgocenia izolacji papierowo-olejowej transformatorów z zaawansowanymi procesami starzenia. Stwierdzono, że skojarzony pomiar „RVM+PDC” poprawia jakość szacowania, zwłaszcza w transformatorach o niejednorodnej morfologii izolacji. Dla zawartości wody w celulozie większej od 3% w analizie zawilgocenia konieczne jest uwzględnienie wyników badań oleju. Pomiar „RVM+PDC” po uwzględnieniu badań olejowych daje możliwość identyfikacji osadów na części aktywnej transformatorów.
EN
Experiences in moisture contents assessment in paper-oil insulation of transformers with advanced ageing processes have been presented. It was found that joint measurement RVM+PDC increases quality of assessment, especially for transformers with non-homogenous morphology of insulation. For water contents in cellulose higher that 3% it is necessary to take into consideration for analysis results of oil tests. The measurement RVM+PDC after considering oil tests allows to identify deposits on the active part of transformers.
11
Content available remote Odpowiedź dielektryczna modelu przepustu wysokiego napięcia
PL
W artykule analizowano procesy relaksacyjne przepustu w modelu oraz rzeczywistym przepuście OIP, na podstawie analizy charakterystyk PDC i testu napięciem schodkowym. Charakterystyki funkcji prądu polaryzacji oraz depolaryzacji mają podobny kształt dla wszystkich napięć pomiarowych, lecz wartości funkcji zależne są od napięcia pomiarowego. Badania wykazały, iż w pomiarach napięciem schodkowym nie występowały dodatkowe zjawiska polaryzacyjne przy zwiększaniu napięcia.
EN
The paper presents analysis of relaxation phenomena in OIP transformer bushing and its model, based on the PDC curves interpretation and step-voltage tests results. Functions of polarization and depolarization currents have similar shape for all measuring voltages, however values are dependent on the voltage level. The research showed, that during step-voltage tests there were no additional polarization phenomena during voltage rise.
12
Content available remote Intelligent nonlinear optimal controller of a biotechnological process
EN
Designing an effective criterion and learning algorithm for finding the best structure is a major problem in the control design process. In this paper, the fuzzy Proportional Parallel Distributed Compensation with Reduced Rule Base approach (PPDC_RRB) is proposed. The design problem considered is essentially nonlinear optimal and robust control problem due to the nonlinear nature of the Takagi-Sugeno fuzzy system. The control signal thus obtained will minimize performance index, which is a function of the tracking/regulating errors, the quantity of the energy of the control signal applied to the system, and the number of fuzzy rules. The genetic learning is proposed for constructing the PPDC_RRB controller. The chromosome genes are arranged into two parts, the binary-coded part contains the control genes and the real-coded part contains the genes parameters representing the fuzzy knowledge base. The effectiveness of this chromosome formulation enables the fuzzy sets and rules to be optimally reduced. The chaotic mutation is introduced for maintaining the population diversity during the evolution process of the genetic algorithm. The performances of the PPDC_RRB are compared with those found by the traditional PD controller with Genetic Optimization (PD_GO). Simulations demonstrate that the proposed PPDC_RRB and PD_GO has successfully met the design specifications.
13
Content available remote Physiology and metabolism of crabtree-negative yeast Debaryomyces occidentalis
EN
This paper is focused on the physiology and metabolism of non-conventional yeasts, especially these belonging to Debaryomyces (syn. Schwanniomyces) occidentialis. In these Crabtree-negative yeast strains, oxygen limitation induces alcoholic fermentation as well as activity of the key fermentative enzymes, pyruvate decarboxylase (PDC) and alcohol dehydrogenase (ADH).
PL
W oparciu o dane literatury przedstawiono fizjologię i metabolizm niekonwencjonalnych drożdży należących do Debaryomyces occidentalis. U tych drożdży tlen indukuje proces fermentacji i aktywność kluczowych enzymów: dekarboksylazy pirogronianowej (PDC) i dehydrogenazy alkoholowej (ADH).
14
Content available remote Procesy relaksacyjne w modelu granicy faz "olej-preszpan"
PL
W artykule zaprezentowano pomiary nieliniowej relaksacji zachodzącej w modelu kanałów olejowych transformatora. Pomiary wykonano dla różnych temperatur metodami RVM, PDC i FDS oraz systemem skojarzonym FDS+PDC. Czas głównej relaksacji występującej w modelu zmienia się eksponencjalnie, a wyliczone na tej podstawie wartości energii aktywacji są znacznie mniejsze dla pomiarów wykonywanych przy stałym polu elektrycznym, niż przy zmiennym. Występujący efekt nieliniowości został potwierdzony pomiarem za pomocą systemu DIRANA.
EN
The paper presents measurements of nonlinear relaxation in model of oil gaps of transformer. Measurements have been conducted in two temperatures using RVM, PDC and FDS methods and also joint FDS+PDC system. The time of model's main relaxation changes in exponential way and values of activacion energy calculated on this basis are significantly lower for measurements taken at DC electric field, than at AC. Nonlinear effect has been confirmed with DIRANA system.
EN
Dielectric measurements and diagnostic methods are established procedures to evaluate moisture as an ageing indicator in commonly used oil-paper insulations of power transformers. Both the measurements themselves as well as the analysis of collected data contain several uncertainties and sources of error. This investigation discusses the sources of error and gives a further insight to the influences of transformer insulation design (geometry), insulation temperature, moisture equilibrium in oil and paper and other aspects regarding practical measurements. The dominating impact on dielectric analysis is related to the insulation temperature rather than insulation geometry. Limits and influences on linear modelling of multilayer insulations by equivalent circuits are described too. The investigation includes all the common dielectric diagnostic methods for oil-paper insulations: Recovery Voltage Method (RVM), Polarisation and Depolarisation Currents (PDC) and Frequency Domain Spectroscopy (FDS).
EN
Recently diagnostic techniques using measurements in time and low frequency domain are very intensive developed. There are used various methods (RVM, FDS, PDC), which allow to evaluate the moisture content of paper insulation or its degradation degree. However up to now in the most cases the interpretation of measurement results is ambiguous. The paper presents field measurement results of different operating time power transformers. The measurement of power transformers were taken using three methods: RVM, FDS, PDC. Analysis of dielectric dispersion in time and frequency domain was also presented. Then the analysis results were compared. It was obtained, that the calculated relaxation time of primary relaxation structure for both measurements in time and frequency domain was the same.