Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 13

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  PCE
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
With the gradual scarcity of high-quality sand and gravel resources, the increasing mud content in concrete aggregates could strongly adsorb on polycarboxylate superplasticizers (PCE), greatly reducing their working performance. Modifying the molecular structure of PCE or compounding sacrificial agents can effectively improve the tolerance to clay minerals. In this article, using different small molecule polyols and polypropylene glycol (PPG) as examples, density functional theory (DFT) was employed to simulate the adsorption between clay minerals and hydration products. This exploration aims to further understand the anti-clay performance of various sacrificial agents from the perspective of adsorption energy. Ca-montmorillonite (CaMMT) exhibits the lowest adsorption energy among different clay minerals, making it the preferred site for sacrificial agent adsorption. With an increase in hydroxyl number, the adsorption energy between polyol sacrificial agents and montmorillonite decreases. Among polymeric polyols, the adsorption energy between PPG 600 and montmorillonite is the lowest (-10.86 eV), indicating superior anti-clay performance by preferentially occupying active sites on montmorillonite. As the interlayer spacing of montmorillonite increases, the adsorption energy between PPG 600 and montmorillonite initially decreases and then increases, reaching the lowest value at c=15.5 Å. There are more electron transfers (0.858) compared to the electron gain and loss, confirming more interaction between the sacrificial agents and montmorillonite at 15.5Å. This article also provides a crucial theoretical basis for the structural design of anti-clay sacrificial agents, offering insights into addressing compatibility issues between PCEs and clay minerals.
EN
The study concentrates on two different genetic programming approaches for determining passenger car equivalent (PCE) values and observing the impact on capacity estimation at urban unsignalized intersections. Considering heterogeneous traffic conditions, a new PCE value is introduced to encompass sustainable modes of public transit vehicles, specifically slow-moving three-wheelers (SM3W), commonly known as E-Rickshaws. Since PCE value is considered an important parameter for capacity calculations, the present study considered 14 unsignalized intersections located in Ranchi city of India. An automatic plate recognition system is employed to have the count of vehicular traffic. The methodologies include age-layered population structure genetic programming (ALPSGP), and the offspring selection genetic programming (OSGP) approach that incorporates static and dynamic variables. Based on the significance test and ranking of the genetic programming (GP) models, the OSGP model is recommended as the most appropriate model for heterogeneous traffic. Sensitivity analysis reported that lagging headway (Hi) is the most contributing factor in PCE estimation. The PCE value of SM3W is found to be 0.81 and that could be incorporated as a new classification of vehicles in Indo-HCM. It is observed that evaluated capacity based on PCE values of OSGP performed admirably in both normal and congested traffic situations.
PL
Ujęcie pięciotorowe wód podziemnych „Zawada” GPW S.A. w Katowicach jest rozlokowane w Karchowicach, Zawadzie i Pyskowicach. Ujęcie eksploatuje wody serii węglanowej triasu w obrębie GZWP Gliwice (nr 330) w ilości ok. 2,5 mln m3/rok, przy zatwierdzonych w 2014 roku zasobach eksploatacyjnych ujęcia 625 m3/h i depresja zwierciadła wody w otworach 12-27 m. Analiza podatności użytkowych wód podziemnych na zanieczyszczenie z uwzględnieniem wyników badań modelowych, aktualnego zagospodarowania terenu oraz miejscowych planów zagospodarowania przestrzennego, wskazują na zróżnicowanie stopnia potencjalnego zagrożenia wód podziemnych. W obszarze ograniczonym izochroną 25-letniego dopływu wody do studni Pyskowice I i II, ujmowany poziom wodonośny jest izolowany miąższą warstwą ilastych utworów miocenu, więc ustanowienie strefy ochronnej, rozumianej jako teren ochrony pośredniej, w tym obszarze jest bezprzedmiotowe. W obszarach ograniczonych izochroną 25-letniego dopływu wody do studni Zawada II i IV oraz Jelina stwierdzono brak dostatecznej izolacji poziomu wodonośnego (wychodnie i wychodnie podczwartorzędowe skał węglanowych triasu). Największym zagrożeniem dla studni Zawada II, IV, Jeliny są zagospodarowanie rolnicze, nieskanalizowane obszary zabudowy wiejskiej oraz wody rzeki Drama, która niesie ładunek związków TCE i PCE wypłukiwany z obszaru Tarnowskich Gór, gdzie były stosowane w przeszłości w procesach technologicznych jako rozpuszczalniki. Wody eksploatowane studniami Pyskowice I i II należą do I i II klasy jakości, podczas gdy podwyższone stężenia NO3 i TCE i PCE w wodzie (8-9ug/dm3) obniżają jakość wody z tych studni do klasy III. Dla zapewnienia ciągłej i bezpiecznej eksploatacji ujęcia wód podziemnych „Zawada” istnieje, uzasadniona warunkami geologicznymi i zagospodarowaniem terenu, potrzeba ustanowienia strefy ochronnej w rejonie studni Zawada III i IV oraz Jelina. Wystąpienie z wnioskiem o ustanowienie strefy ochronnej musi być poprzedzone wnikliwą analiza ekonomiczną, bowiem odkryty, szczelinowo-krasowy zbiornik wodonośny triasu może być odbiornikiem zanieczyszczeń łatwo migrujących zarówno pionowo, jak i lateralnie, bez możliwości samooczyszczenia.
EN
Groundwater well field. Zawada- about 2500000 m3 p.a. of water from the fractured -karst aquiferr Gliwice. Drinking; water is supplied for citizens of Zabrze, Gliw ice, Bytom and other nearby .smaller towns. Analysis of env ironmental conditions and land use revealed spatial differential of groundwater vulnerability to pollution. In the area of wells Pyskowice I and Pyskowice II the aquifer is covered by over a 50-m layer of Miocene clays. On thee other hand, scarce confinement was identified within the capture zones bounded by the isochrone of 25 years of groundwater flow to wells Zawada II, IV and .Jelina. Major threat to quality of groundwater abstracted by these wells is represented by agricultural activity, areas of rural housing without sewage system as well as water infiltrating from the river Drama, contaminated by TCE, and TCE, originating from industrial areas of Tarnowskie Góry town. Elevated concentration of NO3, TCE and PCE in the abstracted groundwater caused its deterioration - the groundwater was qualified lo the third class in accordance with polish regulations. The establishment of well field protection zone is problematic due to the presence of karst and specific character of human activities in the area.
PL
Artykuł przedstawia analizę architektury i funkcjonalności koncepcji PCE (Path Computation Element) w wielodomenowej sieci MPLS. W pracy niniejsze została omówiona i wdrożona implementacja PCE z wykorzystaniem kontrolera sieci SDN OpenDaylight i zwirtualizowanych ruterów Cisco XRv.
EN
The paper analyzes architecture and functionality of PCE (Path Computation Element) concept in multidomain MPLS networks. The work presents an implementation of PCE module deployed in OpenDaylight SDN controller connecting with virtualized Cisco XRv routers.
6
Content available remote Domieszki do betonu – problem kompatybilności
PL
Artykuł dotyczy zagadnienia kompatybilności domieszek do betonu z cementem, a także różnych domieszek między sobą, które jest jednym ze szczególnie istotnych problemów współczesnej technologii betonu. Przedstawiono możliwe przyczyny i skutki braku kompatybilności, ilustrując je odpowiednimi przykładami. Zwrócono uwagę na konieczność prowadzenia dalszych intensywnych prac badawczych w tym obszarze.
EN
The paper deals with the problem of compatibility between admixtures for concrete and cement as well as between various types of modifiers. This is one of the particularly important issues in the contemporary concrete technology. The possible reasons and effects of incompatibility were presented, together with selected examples. Attention was paid to the need of further intensive research works in the discussed area.
EN
Characteristics of Quaternary aquifer pollution by halogenated organic compounds (AOX) was based on: chemical analysis of layer pollution on the industrial dump site, redox conditions and pH changes in groundwater. At very high concentrations of AOX (above 5 mg/dm3) probably the organochlorine compounds are dominating (TOC above 1600 mg/dm3, Cl– 11 g/dm3, Br– 11 mg/ dm3). There is also identified the occurrence of VOX compounds in concentration 6 μg/dm3 for PCE and 9 μg/dm3 for TCE. Distribution of FeMsup>2+ (673 mg/dm3) and Mn2+ (15 mg/dm3) concentrations and also redox potential changes in contaminant plume indicate a transformation of VOX. Reaction scheme was developed under the specific soil and water environment conditions in “Zachem” Chemical Plant, as follow: PCE → TCE → DCM → CO2 + 2H+ + Cl–. Groundwater does not meet any quality standards and is really dangerous for living organisms. The whole contaminated area (i.e. “Zielona” industrial waste dump and range of contaminant plume) requires immediate and effective remediation.
EN
Natural Attenuation (NA) in the case of groundwater contaminated with organic compounds relies mainly on intrinsic biodegradation processes. The aim of reliance on natural processes is to achieve site-specific cleanup objectives within reasonable time frames and costs. Such approach may be considered as a risk reduction/remedial option for groundwater contaminated with trichloroethene (TCE) and tetrachloroethene (PCE) in the vicinity of Nowa Deba waterworks. This case study presents implementation of the USEPA’s guideline „Technical protocol for evaluating natural attenuation of chlorinated solvents in ground water” to asses intrinsic biodegradation potentials in contaminated groundwater in the case of Nowa Deba. Literature and field data collected from wells and piezometers were used to develop a conceptual model of contaminants’ fate and transport from a source to a receptor. The intrinsic biodegradation was investigated basing on available analytical parameters (eg concentrations of oxygen, nitrates, chlorides, and pH, TOC and temperature) that are considered as indicators of TCE and PCE transformation. Preliminary screening was done by giving certain points for these parameters, and interpreted in order to asses intrinsic biodegradation potentials. The results indicate inadequate evidence for intrinsic biodegradation (reductive dehalogenation) of TCE and PCE, thus a limited potential for NA as a remedial/risk reduction option in the studied case, unless some measures for enhancement of TCE and PCE intrinsic biodegradation are applied.
PL
Samooczyszczenie (ang. natural attenuation - NA) w przypadku wód podziemnych zanieczyszczonych substancjami organicznymi polega głównie na samoistnej biodegradacji zanieczyszczeń. Oparcie remediacji na naturalnych procesach zakłada osiągnięcie wymaganych efektów oczyszczania specyficznych dla danego terenu przy zachowaniu rozsądnych ram czasowych i kosztów. Takie podejście może być zastosowane jako jedna z opcji likwidacji zagrożenia/remediacji wody podziemnej zanieczyszczonej trichloroetenem (TCE) i tetrachloroetenem (PCE) w rejonie ujęcia Nowa Dęba (południowo-wschodnia Polska). Do oceny możliwości samoistnej biodegradacji TCE i PCE w rejonie Nowej Dęby wykorzystano procedurę opisaną w dokumencie US EPA „Technical protocol for evaluating natural attenuation of chlorinated solvents in ground water”. Dane archiwalne oraz wyniki badań terenowych zostały użyte do opracowania modelu koncepcyjnego transportu zanieczyszczeń od ogniska do receptora. Samoistna biodegradacja była oceniana na podstawie dostępnych parametrów analitycznych (np. stężenia tlenu, azotanów, chlorków oraz pH, TOC i temperatury wody), które uważane są jako wskaźniki rozkładu TCE i PCE. Ocena polegała na przypisaniu odpowiedniej liczby punktów i wag dla poszczególnych parametrów oraz interpretacji uzyskanych wyników w celu sprawdzenia możliwości samoistnej biodegradacji badanych zanieczyszczeń. Stwierdzono brak jednoznacznych dowodów na samoistną biodegradację (dehalogenację redukcyjną) TCE i PCE w wodach podziemnych w rejonie ujęcia Nowa Dęba. Wynika z tego, że w opisywanym przypadku oparcie remediacji wód podziemnych (i likwidacji zagrożenia dla ujęcia wody) na NA jest możliwe pod warunkiem zastosowania metod wspomagających biodegradację TCE i PCE.
EN
Sonolysis and photodegradation of various compounds such as chlorinated aliphatic hydrocarbons are the recent advanced oxidation processes. Perchloroethylene PCE is one of these compounds mainly used as a solvent and degreaser. In this work, elimination of perchloroethylene in aqueous solution by ultrasonic irradiation and photooxidation by UVC were investigated. Head space gas chromatography with FID detector was used for analyses of PCE. Results showed that PCE could be effectively and rapidly degraded by ultrasonic irradiation, photooxidation by UVC and combination of these methods. The order of studied reactions for degradation PCE has been determined.
EN
Natural Attenuation (NA) in the case of groundwater contaminated with organic compounds relies mainly on intrinsic biodegradation processes. The aim of reliance on natural processes is to achieve site-specific cleanup objectives within reasonable time frames and costs. Such approach may be considered as a risk reduction/remedial option for groundwater contaminated with trichloroethene (TCE) and tetrachloroethene (PCE). This case study presents implementation of the US EPA’s guideline „Technical protocol for evaluating natural attenuation of chlorinated solvents in groundwater” to asses intrinsic biodegradation potentials in TCE and PCE contaminated groundwater in the vicinity of Nowa Deba waterworks (south-east Poland). Literature and field data collected from wells and piezometers were used to develop a conceptual model of contaminants’ fate and transport from a source to a receptor. The intrinsic biodegradation was investigated basing on available analytical parameters (eg concentrations of oxygen, nitrates, chlorides, and pH, TOC and temperature) that are considered as indicators of TCE and PCE transformation. Preliminary screening was done by giving certain points for these parameters, and interpreted in order to asses intrinsic biodegradation potentials. The results indicate inadequate evidence for intrinsic biodegradation (reductive dehalogention) of TCE and PCE, thus a limited potential for NA as a remedial/risk reduction option in the studied case, unless some measures for enhancement of TCE and PCE intrinsic biodegradation are applied.
PL
Samooczyszczenie (ang. natural attenuation - NA) w przypadku wód podziemnych zanieczyszczonych substancjami organicznymi, polega głównie na samoistnej biodegradacji zanieczyszczeń. Oparcie remediacji na naturalnych procesach zakłada osiągnięcie wymaganych efektów oczyszczania specyficznych dla danego terenu przy zachowaniu rozsądnych ram czasowych i kosztów. Takie podejście może być zastosowane jako jedna z opcji likwidacji zagrożenia/remediacji wody podziemnej zanieczyszczonej trichloroetenem (TCE) i tetrachloroetenem (PCE) w rejonie ujęcia Nowa Dęba (południowo-wschodnia Polska). Do oceny możliwości samoistnej biodegradacji TCE i PCE w rejonie Nowej Dęby wykorzystano procedurę opisaną w dokumencie US EPA "Technical protocol for evaluating natural attenuation of chlorinated solvents in ground water”. Dane archiwalne oraz wyniki badań terenowych zostały wykorzystane do opracowania modelu koncepcyjnego transportu zanieczyszczeń od ogniska do receptora. Samoistną biodegradację oceniono na podstawie dostępnych parametrów analitycznych (np. stężenia tlenu, azotanów, chlorków oraz pH, TOC i temperatury wody), które uważane są jako wskaźniki rozkładu TCE i PCE. Ocena polegała na przypisaniu odpowiedniej liczby punktów i wag dla poszczególnych parametrów oraz interpretacji uzyskanych wyników w celu sprawdzenia potencjalnych możliwości samoistnej biodegradacji badanych zanieczyszczeń. Stwierdzono brak jednoznacznych dowodów na samoistną biodegradację (dehalogenację redukcyjną) TCE i PCE w wodach podziemnych w rejonie ujęcia Nowa Dęba. Wynika z tego, że w opisywanym przypadku oparcie remediacji wód podziemnych (i likwidacji zagrożenia dla ujęcia wody) na NA jest możliwe jedynie pod warunkiem zastosowania metod wspomagających biodegradację TCE i PCE.
PL
Przedstawiono przykład zastosowania modelowania numerycznego jako narzędzia do projektowania remediacji zanieczyszczonych wód podziemnych. Wykonane symulacje migracji trichloroetylenem (TCE) i tetrachloroetylenem (PCE) w wodach czwartorzędowego piętra wodonośnego pozwoliły na oszacowanie czasu niezbędnego do osiągnięcia przyjętego celu remediacji (stężenia TCE i PCE w wodzie <50 mg/dm3) dla dwóch scenariuszy remediacji – (I) strategii opartej na samooczyszczaniu wód (Ia – w obecnych warunkach pracy i Ib – przy wyłączonym ujęciu) oraz (II) zastosowaniu metody „pompuj i oczyszczaj”.
EN
An example of the application of numerical modeling as a tool for designing effective remediation of trichloroethene (TCE) and tetrachloroethene (PCE) contaminated groundwater is presented. Simulations of TCE and PCE fate and transport in the Quaternary aquifer were performed for two remediation scenarios – (I) a strategy based on natural attenuation (NA) (Ia – waterworks in operation; Ib – waterworks closed down), and (II) a “pump-and-treat” method.
EN
In this paper, we have investigated the bulk heterojunction organic solar cells based on CuI - polyvinyl alcohol (CuI-PVA) nanocomposite as electron donor and [6,6] - phenyl C60 - butyric acid methyl ester (PCBM) or modified PCBM i.e. F as electron acceptor. The power conversion efficiencies (PCEs) of 0.46 % and 0.68 % were achieved for the photovoltaic devices based on as cast CuI-PVA:PCBM and CuI-PVA:F blend films, respectively. The higher PCEs of the organic solar cells based on F as electron acceptor resulted from the increase in both short circuit current (Jsc) and open circuit voltage (Voc), due to the increased absorption of F in visible region and its higher LUMO level. After thermal annealing, the PCEs of the organic solar cells were further increased to 0.54 % and 0.80 % for CuI-PVA:PCBM and CuI-PVA:F blends, respectively. The increase in the PCEs was mainly due to the increase in Jsc, which has been attributed to the improvement in hole mobility and broadening of the absorption band in the longer wavelength region. The improved hole mobility resulted in more balanced charge transport in the devices based on the thermally annealed blends.
PL
Oceniono stan chemiczny czwartorzędowych wód podziemnych w strefie ochronnej ujęcia Nowa Dęba. Zbadano trendy zmian stężeń wybranych wskaźników w latach 2000–2010. Aktualny stan chemiczny oceniono na podstawie wyników serii pomiarowej wykonanej na obszarze badań na przełomie października i listopada 2010 roku. Ze względu na przekroczenia dopuszczalnych wartości wskaźników wód podziemnych, takich jak pH, Fe, Ni, Al oraz TCE i PCE, wykazano słaby stan chemiczny czwartorzędowych wód podziemnych w rejonie ujęcia. Potwierdzono degradację wód podziemnych związaną z zanieczyszczeniem TCE i PCE.
EN
The goal of this paper was to assess the chemical status of Quaternary groundwater within the protection zone of waterworks in Nowa Dęba. Some trends of changes of selected parameters concentrations from 2000 to 2010 were present. The assessment of actual chemical status was based on the results of measurement series performed in late October and November 2010. Concerning the exceeded permissible values of pH, Fe, Ni, Al, and TCE and PCE, the Quaternary groundwater within the study area represents the poor chemical status. Groundwater contamination with TCE and PCE is considered to be the most important problem in the studied area.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.