EN
Optical coherence tomography (OCT) imaging has become a useful tool in medical diagnosis over the past 25 years, because of its ability to visualize intracellular structures at high resolution. The main objective of this work is to add electronic feedback to the optical coherence tomography setup to increase its sensitivity. Noise added to the measured interferogram obscures some details of examined tissue layered structure. Adjusting signal power level in such a way to improve signal-to-noise ratio can help to enhance image quality. Electronic feedback is added to enhance system sensitivity. A logarithmic amplifier is included in the OCT setup to automatically adapt signal level. Moreover, the resolution of the optical spectrum analyzer is controlled according to the farthest layer detected in the A-scan. These techniques are tested showing an improvement in obtained image of a human nail.
2
Content available remote Podstawowe patologie rogówki. Cz. 4, Metody diagnostyczne – OCT rogówki
PL
Wiele współczesnych aparatów OCT (ang. optical coherence tomography) posiada możliwość zobrazowania przedniego odcinka gałki ocznej, w tym rogówki. Niejednokrotnie można spotkać się z określeniem AS-OCT, co stanowi skrót od angielskiego określenia badania OCT przedniego odcinka (ang. anterior segment, OCT). Prawidłowo i starannie wykonane badanie OCT jest cennym narzędziem diagnostycznym w schorzeniach rogówki – pozwala nie tylko uzyskać ostateczne rozpoznanie, ale także monitorować stan rogówki podczas jej leczenia.
EN
This paper presents analysis of selected noise reduction methods used in optical coherence tomography (OCT) retina images (the socalled B-scans). The tested algorithms include median and averaging filtering, anisotropic diffusion, soft wavelet thresholding, and multiframe wavelet thresholding. Precision of the denoising process was evaluated based on the results of automated retina layers segmentation, since this stage (vital for ophthalmic diagnosis) is strongly dependent on the image quality. Experiments were conducted with a set of 3D low quality scans obtained from 10 healthy patients and 10 patients with vitreoretinal pathologies. Influence of each method on the automatic image segmentation for both groups of patients is thoroughly described. Manual annotations of investigated retina layers provided by ophthalmology experts served as reference data for evaluation of the segmentation algorithm.
EN
Median filtering has been widely used in image processing for noise removal because it can significantly reduce the power of noise while limiting edge blurring. This filtering is still a challenging task in the case of three-dimensional images containing up to a billion of voxels, especially for large size filtering windows. The authors encountered the problem when applying median filter to speckle noise reduction in optical coherence tomography images acquired by the Spark OCT systems. In the paper a new approach to the GPU (Graphics Processing Unit) based median smoothing has been proposed, which uses two-step evaluation of local intensity histograms stored in the shared memory of a graphic device. The solution is able to output about 50 million voxels per second while processing the neighbourhood of 125 voxels by Quadro K6000 graphic card configured on the Kepler architecture.
PL
Nieodpowiednio dobrane soczewki kontaktowe (SK) przyczyniają się do dyskomfortu i zmian w fizjologii oka, prowadząc do poważnych powikłań, co może w konsekwencji przyczynić się do rezygnacji z ich dalszego noszenia. Istnieją przesłanki, że na prawidłowe dopasowanie SK istotny wpływ może mieć kształt ich krawędzi. Za pomocą koherentnej tomografii optycznej (OCT) dokonano rejestracji wpływu profilu krawędzi miękkich SK na nabłonek spojówki w trzech segmentach oka (S – skroniowym, N – nosowym oraz D – dolnym) podczas noszenia soczewek o krawędziach okrągłej, ostrej i typu dłuto. Stopień ingerencji SK w nabłonek spojówki porównano po dwóch i czterech tygodniach noszenia dziennego. Podczas kolejnych wizyt odnotowano wzrost nacisku krawędzi soczewek na nabłonek spojówki, szczególnie w segmencie dolnym. Eksperyment ten stanowi próbę porównania subiektywnej oceny dopasowania SK w lampie szczelinowej z zastosowaniem fluoresceiny z obiektywną metodą pomiaru za pomocą OCT.
EN
Poorly fitted contact lenses (CL) contribute to discomfort and changes in the physiology of an eye, leading to serious complications. It is also one of the primary reasons for discontinuing their wear. We speculate that lens edge design could affect a proper fit of CL. We used optical coherent tomography (OCT) to register the impact of lens edge shape on the conjunctival epithelium in three segments of an eye (S – temporal, N – nasal, and D – bottom) and using lenses with round, sharp and chisel edge. After two and four weeks of daily lens wear, we compared the level of impact on conjunctival epithelium. During further visits we observed a significant increase in edge impact, mostly in the bottom segment. The study attempted to compare subjective evaluation of CL proper fit using biomicroscope with fluorescein and objective OCT measurement proces.
PL
W artykule przedstawiono metody kontroli grubości warstw wierzchnich - nawarstwień usuwanych z dzieł sztuki i obiektów zabytkowych w architekturze. Omówiono również wybrane wyniki eksperymentalne. Dla wielu materiałów, a zwłaszcza tych, z których wykonane są dzieła sztuki i zalegające na nich nawarstwienie, istnieje granica związana ze stopniem oczyszczenia obiektu, jak również ryzyko uszkodzenia powierzchni substancji zabytkowej. W konserwacji dzieł sztuki obowiązuj e, podobnie jak w medycynie, zasada "przede wszystkim nie szkodzić". Omówione w artykule metody kontroli wykorzystywano podczas prac konserwatorskich związanych z usuwaniem warstw wierzchnich - nawarstwień z dzieł sztuki.
EN
The paper presents and discusses the methods of removal control of top layers - encrustation on works of art and architectural monuments. Author presents also and discuss selected experimental results. A particular limit as well as minimal risk of substrate surface damage exist for many materials, especially original works of art materials and lying on it encrustation. Similarly to the medicine, a rule "first of all not to harm" is forced also in the conservation of the works of art. Discussed control methods were utilized during conservation works connected with the removal of top surface layers - - encrustation on works of art.
EN
Purpose of this work is to introduce results of biological objects measurements with Optical Coherence Tomography system working with swept source laser (OFDI system). This specified source with spectrum centred around 1040 nm is dedicated to measure posterior segment of the eye. OCT with this wavelength is expected to be next generation for this sort of systems. Although commonly used 800 nm source enables imaging retina, deeper tissue layers are not available with this wavelength. Longer wavelengths in range of infrared spectrum (e.g. 1040 nm) are being weakly scattered which enables to go down to the choroid layer [1]. Examination this structure composed mostly from blood vessels might be very important for early diagnosis of eye diseases. In this paper system setup, swept source scheme and eye images would be introduced.
EN
Optical Coherence Tomography is 3D imaging technology, which can produce high resolution cross-sectional images of biological issues in vivo and in real time. OCT perfectly fills apparent gap in depth/resolution feature space existing between confocal microscopy and ultrasound methods. The paper explains the concept of OCT method and presents the review of some measurement systems currently offered by most advanced producers and some existing applications used in medicine and biology. The authors suggested the new proposals of applying OCT to some biological investigations e.g.: the estimation of topological changes of wheat roots cultivated in the presence of heavy metals, the evaluation of spatial changes of plant tissues caused by biotic and abiotic stressors.
PL
Optyczna tomografia koherencyjna (OCT) jest trójwymiarową technologią obrazowania, która umożliwia uzyskanie wysokiej rozdzielczości obrazów przekrojów obiektów biologicznych in vivo oraz w czasie rzeczywistym. OCT stanowi pośrednie ogniwo w technologiach obrazowania 3D pod względem głębokości wnikania w materiał oraz rozdzielczości, może być zlokalizowana pomiędzy mikroskopią konfokalną a ultrasonografią. Artykuł wyjaśnia koncepcję OCT oraz prezentuje przegląd stanowisk pomiarowych oferowanych przez czołowych producentów oraz niektóre zastosowania w medycynie i biologii. Autorzy wskazali również nowe możliwości wykorzystania tej technologii do pewnych badań w dziedzinie biologii, takich jak: ocena zmian topologii korzeni pszenicy hodowanej w obecności metali ciężkich, ocena przestrzennych zmian strukturalnych tkanek roślin pod wpływem biotycznych i abiotycznych czynników stresowych.
PL
W artykule omówiono metodę badania wewnętrznej struktury materiałów ceramicznych z wykorzystaniem interferometrii niskokoherentnej. Przedstawiono układ pomiarowy optycznej tomografii koherentnej, wykorzystujący niskokoherentny interferometr do badania niejednorodności występujących w strukturze ośrodków rozpraszających. Zaprezentowano wyniki pomiarów grubości i niejednorodności ceramicznych warstw PLZT. Przeprowadzono rozważania nad możliwościami wykorzystania niskokoherentnych interferometrycznych technik pomiarowych do kontroli i optymalizacji procesów wytwarzania ceramicznych warstw PLZT.
EN
In this article we describe an optical method for inside materials investigation, which is based on low-coherence interferometry (LCI). The experimental LCI system applied in optical coherence tomography (OCT) for non-destructive and non-contact examination of materials inner inhomogeteities is presented. The test results of PLZT ceramics investigation are shown as well as brieff discussion about OCT capability for on-line control of PLZT ceramics manufacturing process.
PL
Przedstawiono światłowodowy system dwuwymiarowej wizualizacji niejednorodnych struktur warstw ceramicznych. Omówiono projekt i fizyczną realizację układu wykorzystującego optyczną, niskokoherentną reflektometrię optyczną, która umożliwia nieinwazyjne i bezkontaktowe obrazowanie wewnętrznych struktur różnych materiałów silnie rozpraszających promieniowanie. Przedstawiono przykładowe wyniki pomiarów wewnętrznych warstw ceramiki LSFO. Dodatkowo przeanalizowano możliwości poprawy rozdzielczości pomiaru systemu OCT przez zastosowanie syntezowanych źródeł promieniowania.
EN
In this paper we present a fiber based Optical Coherence Tomography system for two-dimensional visualization of LSFO ceramic subsurface inhomogeneities. The OCT system is capable for non­destructive and non-contact investigation of highly scattering materials like ceramics. The experimental results of investigation of LSFO ceramic structures has been presented. The usefulness of synthesized light source for improving the measurement resolution has been described.
PL
Przedstawiono zasadę działania i podstawowe właściwości systemu OCT (Optical Coherence Tomography). Na przykładzie folii polietylenowej przedyskutowano możliwości wykorzystania systemu do badanie wewnętrznej struktury warstwowej obiektów niebiologicznych. Omówiono wyniki przeprowadzonych badań nad warstwowymi materiałami przeźroczystymi.
EN
An Optical Low-Coherence Tomography (OCT) is a novel optical measurement technique, which enables non-destructive and non-contact investigation of multilayer structures. In this paper the authors present a laboratory OCT system for surface and subsurface investigation of scattering technical objects such as polymer layers. Preliminary test results on subsurface technical objects investigation using OCT system have been presented and discussed.
PL
Koherentna tomografia optyczna (ang. Optical Coherence Tomography - OCT) jest szybko rozwijającą się metodą obrazowania przekrojów wewnętrznych struktur. Pierwotnie używana do celów biomedycznych, może znaleźć szerokie zastosowanie do badań materiałowych. Jest to uniwersalna technika pomiarowa charakteryzująca się dużą rozdzielczością (rzędu pojedyńczych mikrometrów) połączoną z możliwością obrazowania optycznych ośrodków silnie rozpraszających światło. W artykule przedstawiono możliwe zastosowania OCT do pomiarów technicznych oraz uzyskane wstępne wyniki badań przeprowadzonych na próbkach materiałów warstwowych silnie rozpraszających światło.
EN
Optical coherence tomography (OCT) is rapidly developing method for internal structures imaging. First used in biomedical applications, it can be also applicable for technical materials investigation. It is universal measuring technique with high resolution (single micrometers) combined with possibility of imaging highly scattering media. The article presents possible optical coherence tomography applications to technical measurements and preliminary measurements of highly scattering layered materials.