Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  NZEB
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This article aims at discussing the issue of relation between an existing historic building and modern technology, which may lead to upgrading the historic building to parameters of a nearly zeroenergy building. It focuses on the possibility to adjust the facility to contemporary forms of using without considerable prejudice to its historic substance and identity, on contrary, with due respect for the old tissue in the context of NZEB parametrisation. The adjustment refers to innovative solutions allowing upgrade of the building by using the most effective technologies based on renewable energy, improved power efficiency of the structure, technical equipment, exterior and interior cladding and meeting requirements connected with minimum global cost in the life cycle assessment of the building.
PL
W artykule przedstawiono badania dotyczące określenia związku pomiędzy istniejącym zabytkiem a współczesną technologią, co może prowadzić do przystosowania zabytku do parametrów budynku niemal zeroenergetycznego. Artykuł zwraca uwagę na możliwość przystosowania obiektu do współczesnych form użytkowania bez znaczącego uszczerbku dla jego substancji zabytkowej i tożsamości oraz poszanowania starej tkanki w kontekście parametryzacji budownictwa niemal zeroenergetycznego, wykorzystując innowacyjne rozwiązania umożliwiające poprawę standardu budynku poprzez zastosowanie najefektywniejszych technologii wykorzystujących energię odnawialną, poprawę efektywności energetycznej struktur budowlanych, wyposażenie techniczne, obudowę zewnętrzną i wewnętrzną oraz spełnienie wymogów związanych z minimalnym kosztem globalnym w cyklu życia budynku.
PL
Przedmiotem artykułu jest analiza możliwych usprawnień projektu budynku wielorodzinnego pozwalających na spełnienie wymagań standardu niemal zeroenergetycznego (NZEB), które wejdą w życie w 2021 roku. W ramach analizy w programie Audytor OZC stworzono model 3D dziewięciokondygnacyjnego budynku mieszkalnego. Charakterystykę energetyczną budynku obliczono dla 18 lokalizacji w całej Polsce, reprezentujących różne warunki klimatyczne i źródła ciepła. Uzyskane wyniki pozwoliły sprawdzić, czy budynek spełnia wymagania NZEB (WT 2021) w odniesieniu do współczynnika zapotrzebowania na energię pierwotną (EP ≤ 65 kWh/(m2rok)). W miejscach, w których wskaźnik EP został przekroczony, zaproponowano ulepszenia dotyczące głównie systemów technicznych i wykorzystania OZE (kolektory słoneczne lub fotowoltaika). Rezultatem obliczeń jest „Przewodnik inwestora” pokazujący zalecane usprawnienia w zależności od źródła ciepła i lokalizacji w Polsce. Przedstawiono również stopień trudności spełnienia kryteriów NZEB. Wnioski z artykułu mogą być przydatne dla projektantów i inwestorów planujących budowę budynków wielorodzinnych po 2020 roku. Wyraźnie pokazują, jaki rodzaj konwencjonalnego i odnawialnego źródła ciepła, a także systemów, warto zastosować.
EN
The main objective of this paper is to propose possible improvements of an apartment building design allowing its adaptation to nearly zero-energy (NZEB) requirements, entering into force in the year 2021. Within the research the 3D model of the nine-storey, residential building was created with the help of Audytor OZC software. The energy performance of building was calculated for 18 locations in whole Poland representing different climate conditions and heat sources. The results obtained allowed to check if the building meets the NZEB requirements in regard to primary energy demand factor (EP ≤ 65 kWh/(m2rok)). In the locations where the EP factor was exceeded improvements were proposed including mainly building systems and the use of RES (solar collectors or photovoltaic) for the domestic hot water heating. As a result of the research “Investor’s Guide” was created, demonstrating the recommended solutions depending on the heat source and the location in Poland. The degree of difficulty in meeting the NZEB criteria was presented as well. The paper conclusions can be very useful for designers and investors planning to build multi-family buildings after 2020. They clearly show what kind of conventional and renewable heat source as well as systems to use.
PL
Monitorowanie i modelowanie zachowań użytkowników to bardzo istotne zagadnienie w aspekcie zarządzania energią, szczególnie w przypadku budynków netto zero energetycznych lub netto zero emisyjnych. Spojrzenie na te systemy z perspektywy użytkownika, umożliwia tworzenie dokładniejszych modeli procesów energetycznych zachodzących w obiektach budowlanych. Modele użytkowników mają znaczenie zarówno w fazie projektowej przedsięwzięć inwestycyjnych (symulacje energetyczne), jak i w trakcie eksploatacji obiektów (systemy sterowania). Celem niniejszego artykułu jest omówienie zagadnienia i przedstawienie wybranych projektów badawczych dotyczących tematyki IEA EBC Annex’u 66.
EN
One of the newest concepts of building: net zero energy/emission buildings (NZEB) base building supply side on many energy sources (e.g. renewable and district). The quality of this solution depends on building energy system management. Development of robust energy systems and NZEB require taking into account stochastic character of both supply and demand sides. In this way system performance will be tested against reality related uncertainty. Therefore model of occupant behavior is important both in design phase and during building operation. The design phase is the least expensive period to change building concept, based on results of building performance simulation analysis where appropriate occupant model should be implemented. Building operation is based on control system strategy; it is based on appropriate models of object control: building, building systems and user. The aim of this paper is to describe Annex 66 project and present selected research projects on the subject.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.