Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 9

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  NAA
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This document presents the results of numerical analyses of the SAW gas sensor in the steady state. The effect of SAW velocity changes depending on how the surface electrical conductivity of the sensing layer is predicted. The conductivity of roughness sensing layer above the piezoelectric waveguide depends on the profile of the diffused gas molecule concentration inside the layer. Numerical results for the gas DMMP (CAS Number 756-79-6) for layer (RR)-P3HT in the steady state are shown. The main aim of the investigations was to study the thin film interaction with target gases in the SAW sensor configuration based on diffusion equation for polymers. Numerical results for profile concentration in steady state are shown. The results of numerical acoustoelectric analysis (NAA) allow to select the sensor design conditions, including the morphology of the sensor layer, its thickness, operating temperature and layer type. The numerical results based on the code written in Python, are described and analyzed. The theoretical results were verified and confirmed experimentally.
EN
Scientific objective of this work was elaboration of radiometric method for the development of hydrometallurgical process for recovery of Cu from the copper ore. A neutron activation analysis (NAA) was identified as a very convenient tool for the process investigation. The samples of copper ore were activated in a nuclear reactor. The parameters of the neutron activation were calculated. Radioisotope 64Cu was selected as an optimal tracer, and it was used for the investigation of the leaching process. During the experiments, various processes applying leaching media such as sulphuric acid, nitric acid, and organic acids were investigated. The recovery of the metals using sulphuric acid was insufficient, around 10%. Investigated organic media also did not meet expectations. The best results were obtained in experiments with nitric acid. Up to 90% of Cu and other metals were extracted from the copper ore. Copper concentration calculations obtained by NAA were confimed by inductively coupled plasma mass spectrometry (ICP-MS) technique. Both techniques gave comparable results, but the advantage of the NAA is a possibility for easy online measurements without shutting down or disturbing the system.
EN
Two new group separation schemes, based on ion exchange chromatography, for the selective and quantitative isolation of rare earth elements (REE) from accompanying elements, were devised. After checking their performance with the aid of radioactive tracers, the schemes were further used together with ICP-MS, NAA and ion exchange chromatography for the determination of Sc, Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu in two certified reference materials (CRMs). The results were compared with another series of analyses, where the REEs were determined directly, i.e. without pre-separation, by instrumental neutron activation analysis (INAA) and inductively coupled plasma mass spectrometry (ICP-MS). It was demonstrated that while direct INAA and ICP-MS in most instances provide reliable results for the majority of REEs, for some elements, notably Sc, Yb and Tm in the cases of ICP-MS and INAA, respectively, systematic errors occur or may potentially occur.
EN
The experiment was carried at the Experimental Station of Garlica Murowana near Kraków in 2006 and 2008. In 2007 the experiment was not conducted due to frost damages. The objects of the experiment were fourteen-year-old apple trees 'Šampion' cv. on MM.106 rootstock. The aim of the experiment was to evaluate the influence of ethephon (2-chloroethylphosphonic acid) and auxin NAA (naphthalene acetic acid) used in two terms and concentrations on the yield and fruit quality. First treatment was carried out at the end of flowering (80 % the falling petals), second when fruitlets' diameter was 12 mm. Two concentrations: 20 and 60 mg NAA o dm-3, and 200 and 600 mg ethephon o dm-3 were used each time. Controlled trees were not sprayed. After fruit harvest total yield with division into five classes: apple blush, flesh firmness, extract content, acidity and pH were estimated. Experiments showed that used preparations increased the number of fruit with more than 12 cm diameter and decreased the amount of small fruit in total yield. All used combinations increased pH of fruit juice in comparison with control. Used compounds did not show clear influence on fruit juice's extract contents. Used compounds did not have influence on fruit storage ability assessed.
PL
Doświadczenie przeprowadzono w sadzie doświadczalnym w Garlicy Murowanej koło Krakowa w latach 2006 i 2008. W 2007 r. ze względu na uszkodzenia przymrozkowe nie prowadzono badań. Obiektem badań były intensywnie plonujące czternastoletnie drzewa jabłoni odmiany 'śampion' na podkładce 'iMM.106'. Celem doświadczenia była ocena wpływu etefonu oraz auksyny NAA na ilość i jakość plonu. Każdy z preparatów zastosowano w dwóch stężeniach: 200 i 600 mg etefonu o dm-3 oraz 20 i 60 mg NAA o dm-3. Zabiegi wykonano w dwóch terminach: gdy opadło 80 % płatków korony oraz gdy zawiązek z kwiatu królewskiego osiągnął 12 mm średnicy. Drzewa kontrolne nie były opryskiwane. Podczas zbioru oceniano: plon ogólny z podziałem na klasy wielkościowe, powierzchnię jabłek pokrytych rumieńcem, jędrność miąższu, ekstrakt, ogólną kwasowość soku oraz pH. Wszystkie zastosowane zabiegi spowodowały zwiększenie udziału jabłek o średnicy powyżej 7 cm oraz zmniejszenie ilość owoców drobnych w ogólnym plonie. Stwierdzono również dodatni wpływ zastosowanych zabiegów na wzrost kwasowości soku owoców. W doświadczeniu nie stwierdzono wpływu zabiegów na stopień wybarwienia owoców oraz jędrność miąższu, pH oraz ogólną kwasowość ekstraktu soku. Zastosowane preparaty nie miały wpływu na zdolność przechowalniczą owoców.
EN
Radiochemical separations in NAA employing precipitation, extraction, ion exchange etc. were often planned in such a way that achieving high radiochemical purity of the respective fractions was more important than obtaining quantitative recovery of a given radionuclide. Inactive carriers were usually added and chemical yield was determined by gravimetry, colorimetry, titrimetry, reactivation etc. The other philosophy assumed that separation should be quantitative or nearly quantitative so that the determination of chemical yield is not needed or could be neglected. The examples of some works typical for both philosophies are reminded. Definitive methods are a special case of this second philosophy where the separation must be both highly selective and fully quantitative and where there exist some intrinsic mechanisms safeguarding against making systematic errors. To achieve this goal such method is planned in principle as a single element method. Only in the case when there is a need for the monitoring of a potential interfering reaction, the separation scheme may encompass simultaneous determination of two elements. A few examples of definitive methods by RNAA including those recently elaborated are given.
PL
Rozdzielania radiochemiczne w NAA wykorzystujące strącanie, ekstrakcję, wymianę jonową itp. były często planowane w taki sposób, że osiągnięcie wysokiej czystości radiochemicznej traktowano jako bardziej ważne niż uzyskanie ilościowego odzysku danego nuklidu promieniotwórczego. Rozdzielenie prowadzono zazwyczaj po dodaniu nieaktywnych nośników, a wydajność chemiczną oznaczano za pomocą metod wagowych, miareczkowych, kolorymetrycznych, ponownej aktywacji neutronowej itd. W innym podejściu zakładano, że rozdzielenie powinno być ilościowe lub prawie ilościowe, tak że oznaczanie wydajności chemicznej nie jest potrzebne lub może być zaniechane. W artykule przypomniano przykłady prac typowych dla obu tych filozofii podejścia do rozdzieleń stosowanych w NAA. Metody definitywne są szczególnym przypadkiem tej drugiej filozofii, gdzie założono, że rozdzielenie musi być zarówno w pełni ilościowe, jak i wysoce selektywne oraz, że metoda musi posiadać wewnętrzne mechanizmy zabezpieczające jąprzed popełnieniem grubych błędów. Dla osiągnięcia tego celu metody te sąplanowane w zasadzie jako metody oznaczania tylko jednego pierwiastka. Tylko w przypadku konieczności monitorowania potencjalnie interferencyjnej reakcji, metoda może obejmować oznaczanie dwóch pierwiastków. Przytoczono przykłady kilku metod definitywnych łącznie z tymi, które zostały opracowane w ostatnim czasie.
EN
Trace metals in the brain play an important role in the function of central nervous system (CNS). The objective of this work is to investigate the effects of intranasal exposure of nano- and submicron-sized Fe2O23, particles on the homeostasis of trace metals in the brain. After a single intranasal instillation of nano- and submicron-sized Fe2O23, particles, the contents of Fe, Cu and Zn in the sub-brain regions were determined in the time course from 4 h till to the 30 day post-exposure. Our results indicated that the imbalance of trace metals in the sub-brain regions of mice was induced by the two sizes of Fe2O23, particles. The more significant accumulation of Fe in the brain was found in the nano-Fe2O23., treated mice than in the submicron-Fe2O23, treated ones; meanwhile, similar alterations of Zn contents in the brain were observed as well. A strong positive correlation between Fe and Zn levels in the olfactory bulb of nano-Fe2O23 instilled mice and in the hippocampus and cerebral cortex of submicron-Fe2O23 instilled mice were found. This is the first trial to investigate the disturbance of trace metals in the brain after exposure to Fe2O23 nanoparticles. These results state that much attention should be paid to the potential impact of inhaled FCjCX, nanoparticles on the CNS.
PL
Metale śladowe odgrywająistotnąrolę w funkcjonowaniu ośrodkowego układu nerwowego. Celem tej pracy jest zbadanie wpływu donosowej ekspozycji nano- i submikronowej wielkości cząstek Fe2O23 na homeostazę mikroelementów w mózgu. Badano zawartość Fe, Cu i Zn w czasie od 4 godzin do 30 dni po donosowym podaniu cząstek Fe2O23, o rozmiarach ťano- i submikronowych. Uzyskane rezultaty wskazują, że te dwa rozmiary cząstek Fe2O23., wywoływały zaburzenia równowagi powyższych mikroelementów w różnych strukturach mózgu myszy. W mózgu myszy potraktowanych nano-Fe2O3 zaobserwowano znaczniejszą akumulację Fe niż u myszy potraktowanych submikrono-Fe2O Podobne zmiany zaobserwowano również w zawartości Zn w mózgu. Zaobserwowano istotną korelację między zawartością Fe i Zn w opuszce węchowej myszy, którym podano nano-Fe2O oraz w hipokampie i korze mózgowej myszy potraktowanych submikrono-Fe2O praca ta stanowi pierwszą próbę zbadania zaburzenia poziomu metalicznych mikroelementów w mózgu po ekspozycji nanocząsteczkami Fe2O Uzyskane dane wskazują, że należy zwracać szczególną uwagę na potencjalny wpływ wdychanych nanoczastek Fe2O na ośrodkowy układ nerwowy.
EN
The behaviour of Pb activation peaks, which appear in an X-ray spectrum of Fast Neutron Activation Analysis (FNAA) performed by means of a Plasma Focus (PF) neutron source and an NaI scintillator counter, has been studied. The PF device generates neutron bursts of different intensities. To know the exact neutron flux illuminating a sample during PF discharges an external neutron counter is usually used. The nature and behaviour of the indicated peaks suggest that one could use one of them as an internal standard for neutron production measurement instead of an external counter. This technique allows more reliable and accurate determinations of the presence of various elements.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.