Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  Mg-Li-Al alloys
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The object of investigations was the behaviour of acoustic emission (AE) during channel-die compression at room and elevated (140°C) temperatures of the composites based on Mg12Li3Al and Mg12Li5Al alloys containing the Β phase as well as of the composites based on Mg8Li3Al and Mg8Li5Al alloys also containing the phase. The results of AE measurements at room temperature show that the effect of anisotropy of the fibres distribution with respect to compression axis occurs also in composites based on Mg8Li3Al alloys. However, the results of AE measurements at 140°C show that the course of AE activity was a two-range character and that the level of the rate of AE events is higher than that at room temperature. These effects are attributed to the thermal weakening of the fibres strength at 140°C. Moreover, using an AE analyser of new generation, the investigations of the composites based on Mg8Li5Al and Mg12Li3Al alloys have been carried out at room temperature. On the basis of the constructed acoustograms and spectral characteristics the preliminary wavelet analysis of AE signals generated in the microcracking process of ceramic fibres has been carried out. The results obtained using the old and the new AE analysers are compared and discussed also on the basis of scanning microstructure observations and on the basis of the dislocation mechanisms of deformation and microcracking processes in the composites containing the Β phase of Mg-Li system.
PL
Badania dotyczyły zachowania się emisji akustycznej (EA) podczas testów nieswobodnego ściskania w temperaturze otoczenia i podwyższonej (140°C) kompozytów na osnowie stopów Mg12Li3Al oraz Mg12Li5Al, zawierających faze Β, a także kompozytów na osnowie stopów Mg8Li3Al i Mg8Li5Al, również zawierających fazę Β. Wyniki pomiarów EA w temperaturze pokojowej wskazują, że efekt anizotropii rozkładu włókien względem osi ściskania występuje również w kompozytach na osnowie stopów Mg8Li3Al. Natomiast wyniki pomiarów EA w temperaturze 140°C wskazują na dwuzakresowy przebieg aktywnosci EA oraz większy poziom tempa zdarzeń EA niż w temperaturze pokojowej. Wytłumaczono to osłabieniem termicznym wytrzymałości włókien w 140°C. Ponadto, wykorzystując analizator EA nowej generacji, wykonano badania w temperaturze pokojowej kompozytów na osnowie stopów Mg8Li5Al i Mg12Li3Al. Przeprowadzono analizę porównawczą wyników uzyskanych przy użyciu nowego i dotychczas stosowanego analizatora EA. W oparciu o skonstruowane akustogramy i charakterystyki widmowe, przeprowadzono analizż falkową sygnałów EA generowanych w procesie mikropękania włókien ceramicznych. Wyniki przedyskutowano również w oparciu o obserwacje mikrostruktur skaningowych oraz w oparciu o dyslokacyjne mechanizmy odkształcenia i mechanizmy mikropękania w kompozytach zawierających fazę Β układu Mg-Li.
EN
The study is a continuation of the new research direction, started a few years ago in cooperation with the Institute of Materials and Machine Mechanics of the Slovak Academy of Sciences in Bratislava, in which the acoustic emission (AE) method is used to investigate channel-die compressed Mg-Li-Al based alloys and related composites reinforced with short δ - Al2O3 ceramic fibres. The aim of the studies is further documentation and explanation of the AE phenomenon in Mg-Li-Al alloys and composites based on Α+Β diphase matrix subjected to channel-die compression at ambient and elevated temperatures 140C. Attempt has been made to explain the correlations occurring between AE intensity, AE activity and the plastic deformation characteristics as well as the microstructure observed before and after deformation using the optical and the scanning microscopy. The effect of anisotropy of the fibres distribution with respect to the compression direction has been observed in Mg8Li/δ composites at room temperature, whereas in Mg8Li3Al/δ composites compressed at elevated temperature 140C it has been observed that AE activity occurs in two ranges and that AE intensity is higher than that observed at room temperature. The results are discussed on the basis of the dislocation mechanisms of plastic flow and the mechanisms related with the microcracking processes in Α+Β diphase based alloys and composites.
PL
Temat stanowi kontynuację, zapoczątkowanego kilka lat temu – w ramach współpracy z Instytutem Materiałów i Mechaniki Maszyn Słowackiej Akademii Nauk w Bratysławie – nowego kierunku badań wykorzystujących metodę emisji akustycznej (EA) w testach nieswobodnego ściskania stopów na bazie Mg-Li-Al oraz kompozytów na osnowie tych stopów wzmocnionych krótkimi włóknami ceramicznymi δ - Al2O3. Celem badań jest dalsza dokumentacja i wyjaśnienie zjawiska EA w stopach i kompozytach Mg-Li-Al na osnowie dwufazowej Α+Β, poddanych nieswobodnemu ściskaniu w temperaturze otoczenia i podwyższonej 140C. Podjęto próbę wyjaśnienia korelacji zachodzących pomiędzy przebiegiem intensywności i aktywności EA a charakterystykami deformacji plastycznej oraz mikrostrukturą obserwowana przed i po odkształceniu przy zastosowaniu mikroskopu optycznego i skaningowego. W kompozytach Mg8Li/δ zaobserwowano wystepowanie efektu anizotropii rozkładu włókien względem kierunku ściskania w temperaturze otoczenia. Natomiast w kompozytach Mg8Li3Al ściskanych w podwyższonej temperaturze 140C zaobserwowano występowanie dwóch zakresów aktywności EA i wyższą intensywność EA niż w temperaturze pokojowej. Wyniki przedyskutowano w oparciu o dyslokacyjne mechanizmy plastycznego płynięcia oraz mechanizmy związane z procesami mikropękania w stopach i kompozytach na osnowie dwufazowej Α+Β.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.