Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 27

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  MOS
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
1
Content available Performance Analysis of VoIP Data over IP Networks
EN
The paper presents the results of research and analysis of voice data transmission quality in IP packet networks. It analyses mechanisms allowing for the assessment of packet telephony data transmission quality. Possible transmission quality levels and adequate quality metrics, applicable in the recommendations of standardisation organisations, as well as suggested limit values conditioning acceptable voice data transmission quality were indicated and discussed. A packet network model was designed and tested, taking into account VoIP architecture supporting various audio codecs used for voice compression. Transmission mechanisms based on audio codecs G.711, G.723, G.726, G.728 and G.729 were investigated. It was shown that for delay-sensitive traffic which fluctuates beyond its nominal rate, selected codecs have an advantage over others and allow for better transmission quality of VoIP traffic with guaranteed bandwidth and delay.
EN
Purpose: The aim of this paper was to discuss the design and development of an innovative e-nose system which can detect respiratory ailments by detecting the Volatile Organic Compounds (VOCs) in the expelled breath. In addition to nitrogen, oxygen, and carbon dioxide, the expelled breath contains several VOCs, some of which are indicative of lung-related conditions and can differentiate healthy controls from people affected with pulmonary diseases. Methods: This work detailed the sensor selection process, the assembly of the sensors into a sensor array, the design and implementation of the circuit, sampling methods, and an algorithm for data analysis. The clinical feasibility of the system was checked in 27 lung cancer patients, 22 chronic obstructive pulmonary disease (COPD) patients, and 39 healthy controls including smokers and non-smokers. Results: The classification model developed using the support vector machine (SVM) was able to provide accuracy, sensitivity, and specificity of 88.79, 89.58 and 88.23%, respectively for lung cancer, and 78.70, 72.50 and 82.35%, respectively for COPD. Conclusions: The sensor array system developed with TGS gas sensors was non-invasive, low cost, and gave a rapid response. It has been demonstrated that the VOC profiles of patients with pulmonary diseases and healthy controls are different, hence, the e-nose system can be used as a potential diagnostic device for patients with lung diseases.
EN
Code Excited Linear Prediction (CELP) algorithms are proposed for compression of speech in 8 kHz band at switched or variable bit rate and algorithmic delay not exceeding 2 msec. Two structures of Low-Delay CELP coders are analyzed: Low-delay sparse excitation and mixed excitation CELP. Sparse excitation is based on MP-MLQ and multilayer models. Mixed excitation CELP algorithm stems from the narrowband G.728 standard. As opposed to G.728 LD-CELP coder, mixed excitation codebook consists of pseudorandom vectors and sequences obtained with Long-Term Prediction (LTP). Variable rate coding consists in maximizing vector dimension while keeping the required speech quality. Good speech quality (MOS=3.9 according to PESQ algorithm) is obtained at average bit rate 33.5 kbit/sec.
PL
W referacie przedstawiono koder sygnału mowy o paśmie 8 kHz, działający wg algorytmu CELP z małym opóźnieniem algorytmicznym (do 2 ms). W odróżnieniu od wąskopasmowego kodera G.728, w słowniku wektorów referencyjnych umieszczono sekwencje pseudolosowe i sekwencje otrzymane drogą predykcji długookresowej. W koderze o zmiennej przepływności stosuje się największy wymiar wektora zapewniający wymaganą jakość sygnału mowy. Dobrą jakość sygnału mowy (MOS około 4 według PESQ) otrzymano przy średniej przepływności binarnej rzędu 30 kbit/s.
EN
A CELP coder is proposed for compression of speech in 8 kHz band at variable bit rate and algorithmic delay not exceeding 2 msec. As opposed to narrowband G.728 LD-CELP coder, codebook consists of pseudorandom vectors and LTP sequences. Variable rate coding consists in maximizing vector dimension while keeping the required speech quality. Good speech quality (MOS about 4 according to PESQ algorithm) is obtained at average bit rate 30 kbit/sec.
EN
The MDCT and IntMDCT Algorithm is widely utilized is Audio coding. By lifting scheme or rounding operation IntegerMDCT is evolved from Modified Discrete Cosine Transform. This method acquire the properties of MDCT and contribute excelling invertiblity and good spectral mean. In this paper we discuss about the audio codec like AAC and FLAC using MDCT and Integer MDCT algorithm and to find which algorithm shows better Compression Ratio(CR). The confines of this task is to hybriding lossy and lossless audio codec with diminished bit rate but with finer sound quality. Certainly the quality of the audio is figure out by Subjective and Objective testing which is in terms of MOS (Mean opinion square), ABx and some of the hearing aid testing methodology like PEAQ (Perceptual Evaluation Audio Quality) and ODG (Objective Difference Grade)is followed. Execution measure, that is Compression Ratio(CR) and Sound Pressure Level (SPL) is approximated.
EN
Wastewater treatment processes are subject to numerous disturbances during biological treatment of wastewater. In order to achieve and sustain suitable conditions of the process, basic wastewater parameters should be frequently monitored. While great improvements have been made in the automatization of treatment process, little is known about automatic measuring systems that can detect unusual process conditions in a bioreactor. Tracking these parameters can be difficult and the time required for the determination might vary from several minutes to few days. The objective of this study is to evaluate the use of an electronic nose in-house device (based on a non-selective gas sensor array) for the detection of process disturbances in a lab-scale sequencing batch reactor (SBR) during biological treatment of wastewater with activated sludge. Measurements were performed during a 12-hours working cycle. Continuous analyses of the headspace were performed using a sensor array based on the resistive Metal Oxide Semiconductor type (MOS) gas sensor. Based on the data obtained and the PCA analysis, this study showed that the e-nose technology can be used to predict or retrieve information about potential disruptions during wastewater processes using the e-nose technology.
PL
W artykule, na podstawie zapisów w dokumentach STANAG 2929 - naprawa zniszczeń lotniskowych (ADR) oraz zawartych w Dyrektywie Dowództwa Sojuszniczych Sił Zbrojnych NATO 80-15, opisana została metodyka i kryteria szacowania zniszczeń lotniskowych, które mogą powstać po uderzeniach na lotniska danego kraju określonym ładunkiem konwencjonalnym.
EN
Based on the provisions in STANAG 2929 – airport damage repair (ADR) and those included in the Directive of Allied Armed Forces Command 80-15, the article de- scribes methodology and criteria for estimating airport damage, which might appear after a country’ airports have been struck with a particular conventional missile.
PL
W Eurokodzie PN-EN 1991-1-4 [11] brakuje wytycznych projektowych umożliwiających oszacowanie sił aerodynamicznych działających na obiekty o nietypowym kształcie. W referacie porównano zatem charakter przepływu powietrza o dużych, coraz częściej występujących na świecie prędkościach w pobliżu obiektów w kształcie połowy torusa (np. fragmentu zjeżdżalni wodnej) i dwóch walców o sumarycznej długości równej długości osi połowy torusa, ustawionych poziomo oraz odchylonych od poziomej płaszczyzny pod kątem ß = 45°. Porównano również siły aerodynamiczne działające na połowę torusa - opór aerodynamiczny i poziomą siłę prostopadłą do niego, z siłami działającymi na walce. Wyniki otrzymano na podstawie analiz numerycznych: MES i MOS, wykorzystując moduły: CFD (Computational Fluid Dynamics) i FSI (Fluid-Structure Interaction).
EN
Eurocode EN 1991-1-4 [11] does not include issues concerning wind loads acting on constructions in a non-typical shape. Therefore, in the paper the character of high-speed air flow, which increasingly occurs in the world around objects in the shape of a half - torus (eg. a fragment of a water slide) and two cylinders positioned horizontally and inclined to the horizontal plane at an angle ß = 45° were compared. Also aerodynamic forces acting on a half of the torus - an aerodynamic resistance and a horizontal force perpendicular to the direction of a wind velocity, were compared with forces acting on cylinders. Results are based on numerical analysis: FEM and FVM using the following modules: CFD (Computational Fluid Dynamics) and FSI (Fluid-Structure Interaction).
EN
The paper presents the results of characterization of MOS structures with aluminum oxide layer deposited by ALD method on silicon carbide substrates. The effect of the application of thin SiO2 buffer layer on the electrical properties of the MOS structures with Al2O3 layer has been examined. Critical electric field values at the level of 7.5–8 MV/cm were obtained. The use of 5 nm thick SiO2 buffer layer caused a decrease in the leakage current of the gate by more than two decade of magnitude. Evaluated density of trap states near the conduction band of silicon carbide in Al2O3/4H-SiC MOS is about of 1×1013 eV−1cm−2. In contrast, the density of the trap states in the Al2O3/SiO2/4H-SiC structure is lower about of one decade of magnitude i.e. 1×1012 eV−1cm−2. A remarkable change in the MOS structure is also a decrease of density of electron traps located deeply in the 4H-SiC conduction band below detection limit due to using of the SiO2 buffer layer.
PL
Celem pracy jest określenie możliwości wykrywania zakłóceń w przebiegu procesu oczyszczania ścieków prowadzonych za pomocą reaktora typu SBR przy zastosowaniu elektronicznego nosa skonstruowanego z wykorzystaniem matrycy nieselektywnych rezystancyjnych czujników gazu. Pomiarów dokonywano podczas procesu oczyszczania ścieków miejskich, który przeprowadzano w cyklu 12-godzinnym w bioreaktorze laboratoryjnym. Wykonano ciągłe pomiary powietrza pobieranego ponad zwierciadłem ścieków w reaktorze SBR za pomocą matrycy czujnikowej opartej na rezystancyjnych czujnikach gazu typu MOS podczas stabilnej pracy systemu oraz symulacji awarii procesu napowietrzania. Do interpretacji wyników wykorzystano analizę PCA. Przeprowadzone badania laboratoryjne wskazują, że, wykorzystując matrycę czujnikową, można wnioskować o przebiegu procesu oczyszczania ścieków w reaktorze i natychmiast uzyskiwać informację o stanach odbiegających od normy.
EN
The objective of this article is to determine the possibility of biological process disturbances detect in SBR reactor using developed electronic nose device with application of non-selective gas sensor array. The SBR reactor allows to reduce organic carbon and nutrients concentration level. Measurements were performed during wastewater treatment, which was conducted in 12 hours working cycle. Continuous headspace analysis using the sensor array based on a resistive gas sensors MOS type was performed. To interpret the results, the PCA analysis was applied. Conducted studies have shown that using a sensor array it is possible to inform about abnormal conditions meaning disturbances of the process.
11
Content available Ocena jakości usług telefonii pakietowej
PL
W artykule kompleksowo opisano podejście do zagadnienia oceny jakości usług telefonii pakietowej. Na wstępnie dokonano systematyki pojęć związanych z oceną jakości, wyjaśniając m.in. różnicę pomiędzy używanymi w tym kontekście terminami QoS (Quality of Service) oraz QoE (Quality of Experience). Następnie omówiono możliwe poziomy oceny jakości, tj. poziom sieci, aplikacji i użytkownika, opisując dla każdego z nich adekwatne metryki jakościowe, stosowne rekomendacje organizacji standaryzujących oraz sugerowane wartości graniczne warunkujące akceptowalną jakość. Dla poziomu użytkownika dokonano krótkiej systematyki stosowanych metod oceny, koncentrując się na metodzie E-model z zalecenia ITU-T G.107 [1]. E-model jest nieinwazyjną, pasywną metodą pozwalającą na oszacowanie subiektywnej oceny użytkownika w skali MOS (Mean Opinion Score) na bazie wartości parametrów obiektywnych tzn. w pełni mierzalnych. W pracy zilustrowano praktyczne zastosowanie E-modelu, wyjaśniając sposób pozyskiwania niezbędnych dla niego wartości m.in. z raportów protokołu RTCP (Real Time Control Protocol).
EN
This paper summarizes quality evaluation of the IP packet telephony service. At the beginning the taxonomy of the quality related concepts is introduced and the fundamental differences between QoS (Quality of Service) and QoE (Quality of Experience) approaches are explained. Furthermore the possible quality evaluation levels including user, application and network perspective are proposed and for each quality evaluation level the relevant recommendations of 23 standardization bodies, the adequate metrics and associated thresholds necessary for the acceptable service quality are discussed. For the user level, the brief review of the quality evaluation methods is presented with the special focus on E-model as defined in ITU-T G.107 [1] recommendation. E-model is a not invasive passive method that let to estimate the user subjective opinion in MOS (Mean Opinion Score) scale based on the values of the measurable objective parameters. In this paper the practical application of the E-model is described including details related to acquisition of the necessary values from RTCP (Real Tome Control Protocol) reports.
EN
The large variety of video data sources means variability not only in terms of included content, but also in terms of quality.Therefore, quality assessment provides an additional dimension.The paper describes a comprehensive evaluation experiment on perceived video quality. Consequently, in summary, 19 200 000 video frames will be processed. Given the scale of the experiment, it is set up on a computer cluster in order to accelerate the calculations significantly. This work on Quality of Experience (QoE) is synchronized with that conducted by the Video Quality Experts Group (VQEG), in particular the Joint Efforts Group (JEG) – Hybrid group project.
13
Content available remote QoE Optimized Resource Allocation in Multiuser OFDM Systems
EN
The resource allocation in multiuser Orthogonal Frequency Division Multiplexing (OFDM) systems is addressed, which aims to maximize the user-perceived quality of services instead of the conventional objective metrics. By introducing the previous application-centric Mean Opinion Score (MOS) assessment model, the problem is formulated as a bounded optimization problem, which is non-concave and difficult to develop a closed-form solution. A heuristic algorithm, which couples bound relaxation technique with further fix and drop operations is then proposed for the final solution. Simulation results indicate that our proposal can improve the overall perceived quality from users’ perspective as well as the fairness between users, in comparison with the classical throughput-oriented algorithm.
PL
Artykuł analizuje system OFDM (orthogonal frequency division multiplexing) do alokacji zasobów przy wielu użytkownikach i przesyle dużych wielkości danych. Metoda wykorzystuje serwisy QoS – Quolity of service i QoE – quality of experience.
EN
An ideal objective image quality assessment method should be linearly correlated with subjective scores expressed as Mean Opinion Scores (MOS) or Differential MOS. Such scores are representative for the human perception of various types of image distortions and can be obtained from several image quality databases containing a number of images corrupted by various distortions and their MOS/DMOS values. Unfortunately, the relation between even the most recently proposed image quality assessment methods and subjective scores is nonlinear. In order to compensate this, the Video Quality Experts Group has recommended the use of the logistic function for the additional nonlinear mapping. Nevertheless, its parameters obtained for each database are different so some other functions, e.g. simple polynomials, can also be applied for this purpose. The analysis of the results obtained for currently available image databases is presented in the last part of the paper.
EN
In this study, we present a novel method for the improvement of immunity on MeV electron radiation of MOS structures by means of ultra-shallow fluorine implantation in classical Reactive Ion Etching (RIE) reactor. Obtained results have shown that the fluorination of silicon surface in r.f. CF₄ plasma results in the stability of flat-band voltage (Ufb) values, smaller effective charge (Qeff/q) and interface traps density (Ditmb), as well as higher values of breakdown voltage (Ubr), in comparison to MOS structures fabricated on non-fluorinated silicon substrates. Presented results have shown the potential to apply proposed fluorination method for radiation-hard semiconductor devices.
PL
W artykule przedstawiono metodę poprawy odporności struktur MOS na naświetlanie wysokoenergetycznymi elektronami. Metoda ta polega wprowadzeniu fluoru w obszar interfejsu struktury MOS za pomocą procesu ultrapłytkiej implantacji z plazmy w.cz. typu CF₄. Otrzymane wyniki pokazują, że struktury testowe MOS z warstwą pasywującą bogatą we fluor wchodzącą w skład dielektryka bramkowego, charakteryzują się znacznie stabilniejszymi wartościami napięć płaskich pasm (Ufb), niższymi wartościami ładunku efektywnego w obszarze dielektryka bramkowego (Qeff/q), niższymi wartościami gęstości stanów pułapkowych w środku pasma przewodnictwa (Ditmb) oraz wyższymi wartościami napięć przebicia (Ubr), w porównaniu ze strukturami MOS pozbawionymi, w obszarze dielektryka bramkowego, warstwy pasywującej bogatej we fluor. Zaprezentowane w artykule wyniki pokazują możliwości wykorzystania zaproponowanej przez autorów metody fluoryzacji w obszarze urządzeń elektroniki HARD-RAD.
16
Content available remote Badania łącza internetowego do transmisji głosu (VOIP)
PL
W artykule została przedstawiona analiza przeprowadzonych badań praktycznych, dotyczących jakości połączeń głosowych z wykorzystaniem sieci pakietowych oraz zostały podane przykłady metod, mogących służyć do oceny jakości łącza internetowego. Zaprezentowano przykładowe metody oceny jakości głosu, ich klasyfikację oraz sposoby pomiaru parametrów charakteryzujących jakość usługi. Uwzględniono zarówno metody profesjonalne, takie jak pomiar MOS (ang. Mean Opinion Score) za pomocą P.862 i algorytmu PESQ (ang. Perceptual Evaluation of Speech Quality), jak i metody dostępne dla użytkownika domowego. Przedstawiono środowisko testowe do badań jakości głosu. Pozwalało ono na zbadanie wpływu parametrów łącza internetowego, takich jak przepustowość, straty pakietów oraz opóźnienie.
EN
The article presents an analysis of the practical examinations of the quality of voice calls using the packet network and there are examples of methods that can be used to evaluate the quality of the Internet connection. Some exemplary methods for evaluate voice quality, their classification and methods of measurement of parameters characterizing the quality of service. It reflects also the professional methods, such as measurement of MOS (Mean Opinion Score) with P.862 PESQ algorithm and (Perceptual Evaluation of Speech Quality) and the methods available for the home user. Presents the test environment to test voice quality. This allowed it to examine the impact of Internet connection parameters such as throughput, packet loss and delay.
PL
W pracy przedstawiono analizę zmian parametrów elektrycznych i niezawodnościowych, jakie wprowadza obecność bogatej we fluor warstwy w strukturze bramkowej układu MOS (MIS] z dielektrykami bramkowymi wytwarzanymi metodą PECVD. Powierzchnia podłoży krzemowych przed wykonaniem struktur testowych poddana została odmiennie, niż spotyka się to najczęściej w literaturze, procesom ultra-płytkiej implantacji jonów z plazmy CF₄. Uzyskane wyniki wskazują, że badane układy MOS (MIS), wykonane na zmodyfikowanych podłożach krzemowych, charakteryzują się mniejszymi (co do wartości bezwzględnej) wartościami napięcia płaskich pasm (UFB) oraz ładunku efektywnego (Qeff) w porównaniu do struktur referencyjnych. Nie zmienia się natomiast znacząco gęstość stanów powierzchniowych w środku pasma energii zabronionej krzemu (Ditmb). Wprowadzenie fluoru w obszar graniczny półprzewodnik/dielektryk struktur MOS (MIS) powoduje w konsekwencji także nieznacznie zmniejszenie wartości przenikalności elektrycznej warstw dielektrycznych.
EN
In this work, the analysis of changes in electro-physical and reliability properties, which introduce fluorine-rich dielectric layer formed in the gate of MOS (MIS] structures with PECVD dielectric layers, has been reported. In contrary to commonly found in literature ways, ultra-shallow fluorine implantation from CF₄ plasma of silicon substrates, before the fabrication of test structures, was performed. Presented results have shown, that investigated MOS (MIS) structures, fabricated on modified silicon substrates, are characterized by lower (in absolute values) flat-band voltage (UFB) and effective charge (Qeff) values in comparison to reference structures. Moreover, interface states density in the middle of silicon forbidden band values (Ditmb do not seem to differ significantly In consequence, introduction of fluorine into the semiconductor/dielectric interface of MOS (MIS] structure results in a small decrease of permittivity constant of PECVD dielectric layers.
PL
Bezpieczeństwo układów kryptograficznych w ostatnich latach zostało poważnie zagrożone poprzez metody zaliczane do kategorii ataków typu Side-channel (SCA). Techniki "łamania" sprzętu okazały się być dużo bardziej skuteczne (szybsze i tańsze) w porównaniu do technik klasycznej kryptoanalizy. W obronie przed SCA powstał szereg implementacji zabezpieczających układy przed ulotem informacji (poprzez prąd zasilania czy promieniowanie elektromagnetyczne), a między nimi także Różnicowa Technika Prądowa (RTP). W niniejszym artykule przedstawiono i publikowano po raz pierwszy, układy temarnego dodawania i mnożenia - wykonane w oparciu o bramki RTP. Właściwości arytmetyki różnicowo-prądowej pozwalają zrealizować każdą z tych operacji przy użyciu zaledwie dwóch bramek RTP, co czyni te układy konkurencyjnymi w stosunku do analogicznych realizacji wykorzystujących tradycyjne bramki CMOS.
EN
In recent years, the security of cryptographic circuits was threatened by the methods called Side-channel Attacks (SCA). "Breaking" circuits appeared to be much more efficient (faster and cheaper) in comparison to the classical cryptanalysis. In the opposite part of research, countermeasures against leaking data from the circuits were invented (against side channels like power current or electromagnetic emanation) and in between also the Differential Current Mode Technology (DCMT). In this article were presented. and published for the first time, circuits for ternary addition and multiplication - based on DCMT gates. Features of differential and current arithmetic allow to performe each of these functions by using only two DCMT gates. This accomplishment makes the DCMT circuits competitive in comparison to circuits based on traditional CMOS gates.
PL
W pracy przedstawiamy model struktury tunelowej MOS z podwójną barierą potencjału (DB) i wyniki symulacji jej charakterystyk prądowo- napięciowych. Przedstawiamy dyskusję wpływu rozpraszania nośników w obszarze studni potencjału na mechanizm tunelowego transportu przez strukturę.
EN
In the paper, a theoretical model of the double barrier (DB) MOS tunnel structure and results of simulations of its current-voltage characteristics are presented. An impact of scattering in the well region on the tunneling transport mechanism through the structure is discussed.
PL
Praca dotyczy problematyki estymacji parametrów modelu Danga tranzystora MOS z wykorzystaniem programu MODEL EDITOR, występującego w pakiecie oprogramowania PSPICE. Na przykładzie arbitralnie wybranego typu tranzystora MOS zbadano wpływ doboru liczby oraz rozmieszczenia punktów pomiarowych na charakterystykach tranzystora, na uzyskane wartości parametrów rozważanego modelu. Przeprowadzono również estymację parametrów rozważanego w pracy tranzystora w oparciu o jego dane katalogowe.
EN
The paper deals with a problem of estimation of the Dang model parameters of MOSFET, using a specialized program MODEL EDITOR, included in the PSPICE software package. Influence of the number and the distribution of the MODEL EDITOR input data of the arbitrarily chosen MOSFET on the results of estimation, has been examined. Estimation of the model parameters based on the transistor catalogue measuring data has been also performed.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.