Content available Deteriorated steel culvert under static loading
EN
The paper describes full-scale tests of a 7,25 m long corrugated steel pipe with a diameter of 1.40 m. The corrugation pattern was 125x26mm and the steel was 2 mm thick. The backfill height over the pipe crown was 0,5 m. The deterioration of the tested steel pipe was simulated by removing a part of its bottom. Strain gauges and optical prisms were installed on the metal surface to determine the stresses, internal forces in the metal shell and additionally its deformation. The results of the measurements are presented as graphs and tables. The main goal of the full-scale tests was to assess the performance of the deteriorated steel pipe subjected to static loads and to evaluate the changes in the distribution of the internal forces, caused by the increasing corrosion of the bottom part of the tested pipe.