EN
Clean rooms, including operating rooms, are energy-intensive. During their operation, the concentration of particles in the air, air temperature and humidity are strictly monitored. HVAC systems in the operating room are subject to high demands on maintaining a stable heat and humidity microclimate, as well as particle concentrations within the permitted range. To cover heat losses and heat loads of the building, it is necessary to dimension ventilation equipment with high outputs and high energy consumption. By suitable optimization of the dispositional location of the operating tract in the building and the use of suitable thicknesses of insulating material, it is possible to reduce the performance requirements for the HVAC system, which significantly reduces energy consumption. Heat loss and heat load of the operating tract were evaluated using TechCon software. The performance values of the heaters and coolers for the HVAC units were calculated in the VentiCad design software. The optimization indicates a significant reduction in heat loss and heat load, as well as a reduction in the required temperature of the air supplied to the room by more than 10°C.
PL
Pomieszczenia czyste, łącznie z salami operacyjnymi wymagają dużo energii. Podczas ich pracy dokładnie monitoruje się stężenie cząstek stałych w powietrzu, jego temperaturę i wilgotność. Systemy grzewcze, wentylacji i klimatyzacji (HVAC) w salach operacyjnych podlegają wysokim wymaganiom związanym z utrzymaniem stabilnego mikroklimatu cieplno-wilgotnościowego, jak również stężenia cząstek w dozwolonym zakresie. Pokrycie strat i zysków ciepła budynku wymaga projektowania systemów wentylacyjnych o wysokim zużyciu energii. Poprzez odpowiednią optymalizację lokalizacji przewodów w budynku i zastosowanie właściwiej grubości materiału izolacyjnego możliwe jest odgraniczenie wymagań układów HVAC, co znacząco zmniejsza zużycie energii. Straty i zyski ciepła określono przy użyciu programu TechCon. Parametry nagrzewnic i chłodnic w układzie HVAC wyznaczono w programie VentiCad. Optymalizacja wskazuje na znaczącą redukcję strat i zysków ciepła, jak również zmniejszenie temperatury powietrza dostarczanego do pomieszczenia o więcej niż 10°C.
PL
W artykule zaprezentowano algorytmy energooptymalnego sterowania standardowym systemem HVAC (Heating, Ventilation, Air Conditioning) z recyrkulacją, odzyskiem ciepła (obrotowym regeneratorem energii) i chłodnicą suchą w obiegu recyrkulacyjnym dla pomieszczenia czystego ISO5 (M3.5, kl. 100). Wyznaczono roczne zapotrzebowanie na energię użytkową, końcową i pierwotną dla obróbki termodynamicznej powietrza i przypadku realnych obciążeń oraz parametrów eksploatacyjnych, a także dwóch wariantów sterowania: standardowego - wariantu I i energooptymalnego - wariantu II. Jako narzędzie analizy sformułowano model symulacyjny działania systemu HVAC w ciągu całego roku. Wykazano, iż wdrożenie algorytmów sterowania energooptymalnego (wariantu II) pozwala zmniejszyć roczne zapotrzebowanie na energię pierwotną systemu HVAC aż o 39,2% w stosunku do strategii standardowej (wariantu I).
EN
The article presents algorithms of energy-optimal control of a standard HVAC system with recirculation, heat recovery (rotary energy regenerator) and a dry cooler in a recirculation cycle for a cleanroom ISO5 (M3.5, cl. 100). The annual demand for usable, final and primary energy was determined for thermodynamic air treatment and the case of real loads and operating parameters, as well as two control variants: standard - variant I and energy-optimal - variant II. A simulation model of the HVAC system operation throughout the year was formulated as an analysis tool. It has been shown that the implementation of energy-optimal control algorithms (variant II) allows to reduce the annual primary energy demand of the HVAC system by as much as 39.2% compared to the standard strategy (variant I).
PL
W artykule przedstawiono rozwiązania systemów ogrzewania, wentylacji i klimatyzacji – HVAC (Heating, Ventilation, Air conditioning) dla wybranej realizacji szpitala. Jest to szpital ginekologiczno-położniczy wraz z funkcją usługową – obiekt czterokondygnacyjny o powierzchni około 3300 m2 z garażem podziemnym i nadbudową techniczną na dachu. Zaprezentowano klasyczne rozwiązania systemów wentylacji, klimatyzacji, chłodu dla klimatyzacji oraz ogrzewania. Przedstawiono uwarunkowania i wyzwania na etapie projektowania, na podstawie których dokonano wyboru struktury systemów HVAC. Dotyczy to zwłaszcza uwarunkowań technologicznych, akustycznych, architektonicznych oraz energetycznych. Uwarunkowania te były podstawą wyboru wariantu recyrkulacji powietrza w układach klimatyzacyjnych sal operacyjnych, struktury systemu wentylacji i klimatyzacji dla wybranych funkcji: sal nadzoru poznieczuleniowego, sal porodowych, funkcji usługowej – stacji dializ, a także źródła chłodu dla klimatyzacji oraz struktury całego systemu – w tym lokalizacji urządzeń.
EN
The article presents solutions for heating, ventilation and air conditioning systems – HVAC (Heating, Ventilation, Air conditioning) for a selected hospital implementation. It is a gynecology and obstetrics hospital with a service function – a fourstorey facility with an area of approximately 3,300 m2 with an underground garage and a technical superstructure on the roof. Classic solutions for ventilation, air-conditioning, cooling, air-conditioning and heating systems were presented. Conditions and challenges at the design stage were presented on the basis of which the HVAC system structure was selected. This applies in particular to technological, acoustic, architectural and energy conditions. These conditions were the basis for the selection of the variant of air recirculation in the air conditioning systems of operating rooms, the structure of the ventilation and air conditioning system for selected functions: post-anesthesia supervision rooms, delivery rooms, service function – dialysis station, as well as a cooling source for air conditioning and the structure of the entire system – including location devices.
PL
Mieszkańcy krajów wysokorozwiniętych ekonomicznie i gospodarczo większość swojego czasu spędzają w pomieszczeniach zamkniętych. Warunki kształtujące się w pomieszczeniach zależą od wielu czynników zmieniających się dynamicznie w ciągu doby. W artykule skupiono się na scharakteryzowaniu parametrów mikroklimatu wpływających na odczucie komfortu cieplnego w oparciu o wytyczne zawarte w Polskich Normach oraz rozporządzeniach. Przedstawiono wymagania prawne i zalecenia normatywne do założeń na etapie projektowania systemów HVAC dla obiektów biurowych. Dla wybranego budynku biurowego zaproponowano system wentylacyjny wraz z analizą wilgotności względnej powietrza wewnętrznego oraz stężenia dwutlenku węgla w zależności od przyjętych jednostkowych strumieni powietrza pierwotnego (zewnętrznego) zalecanych przez Polskie Normy.
EN
In highly developed countries, people spend most of their time indoors during the day. Conditions forming in them depend on many factors that change dynamically throughout the day. The article focuses on characterizing the microclimate parameters affecting the feelings of thermal comfort. Legal requirements and normative recommendations were presented to the assumptions at the design stage of HVAC systems for office buildings were presented. For selected office building, an analysis of air humidity and carbon dioxide concentration was performed as a function of the adopted unitary primary (external) air flows recommended by Polish Standards.
EN
This paper presents selected aspects of an alternative power supply for small HVAC systems. The application of a system based on photovoltaic cells together with energy accumulation in VRLA gel batteries was analysed. The results were obtained using laboratory installation and were compared with the predicted data.
PL
W artykule przedstawiono wybrane aspekty alternatywnego zasilania małych systemów HVAC w energię elektryczną. Analizowano zastosowanie systemu opartego na baterii ogniw fotowoltaicznych z akumulacją energii przy użyciu akumulatorów żelowych VRLA. Porównano przykładowe wyniki pomiarów przeprowadzonych na instalacji badawczej z danymi prognozowanym.
EN
Considering the selection of thermal envelope, internal heat gains, building air tightness and range of high-performance HVAC systems leads us to a conclusion that each building must be treated as a complex energy system where the selection of technical equipment and construction methods should be based on a multicriteria decision making algorithm. The paper presents the application of a general algorithm for integrated design of indoor climate comfort system for low energy buildings in selecting of a heating-ventilation system. As the case study a multifamily house has been selected. In order to rank five technically acceptable solutions, four evaluation criteria have been taken into consideration: fossil fuels primary energy consumption, carbon dioxide emission, investment cost and total cost of system operation. As the decision tool a modified weighted sum method has been used.
EN
Nowadays, because of higher energy costs and the awareness of the environmental issues a general trend can be observed to increase the energy efficiency of heating ventilation and air conditioning (HVAC) systems. The paper demonstrates that this aim can be achieved by highly stable control allowing for operation close to the specification limits, where the highest profitability can be obtained. In this regard, black-box models of both the controlled zone air temperature and humidity are constructed for a subsequent analysis of the present control system via a computer simulation. The results obtained are utilised for tuning of controllers on a real plant leading, subsequently, to substantial energy savings. The paper also investigates a potential scope for further energy savings.
8
PL
W czwartym już, kolejnym artykule z cyklu korozja instalacji sanitarnych, przedstawiono mechanizm korozji naprężeniowej a także korozji międzykrystalicznej. Te typy korozji spotykane są w instalacjach sanitarnych, przede wszystkim w wyrobach wykonywanych ze stali odpornych na korozje. Stale te coraz częściej stanowią materiał konstrukcyjny urządzeń stosowanych w instalacjach sanitarnych. W kraju stal odporna na korozję jest najczęściej materiałem, z jakiego wykonuje się wymienniki ciepła, ale także zasobniki ciepła, podgrzewacze wody czy grzejniki.
EN
In the fourth article from the series concerning corrosion in HVAC systems, the mechanism of functioning of the stress and intcrcrystalline corrosion was presented. Those corrosion types are usually seen in Hvac systems, where the materials used to produce the devices were corrosion-proof. Corrosion-proof materials are more and more often used for sanitary devices construction. In Poland most often corrosion-proof materials are used to produce heat exchangers, as weel as thermal storage vessels, water heaters or radiators.