Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  HPLC determination
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Investigation of permeation of acyclovir through skin using alaptide
EN
The investigation deals with the affection of the permeation of acyclovir through full-thickness pig ear skin using a Franz diffusion cell from the donor vehicles of phosphate buffer (pH 7.4) and propylene glycol–water (1:1) using synthesised (S)-8-methyl-6,9-diazaspiro[4.5]decane-7,10-dione, alaptide as a transdermal permeation enhancer. Alaptide was applied in ratio 1:10 (w/w) relative to the amount of acyclovir. At the first hour after application, the permeated amount of acyclovir from propylene glycol–water system, simulating semisolid dosage forms, was ca. four-fold higher than from the formulation without alaptide. Despite that the enhancement ratio of alaptide in a steady state was 1.7, the pseudo-enhancement ratio of alaptide in the time range of first to third hour was 2.3. Both enhancement ratios indicate that alaptide modifies skin structure, while the short-term application of the alaptide formulation seems to be more advantageous.
EN
Aripiprazole is a novel atypical antipsychotic drug used in the treatment of schizophrenia. The sensitive and reproducible ion pair RPLC method was developed and validated for determination of aripiprazole and its nine impurities, which are significantly different in polarity. The separation was performed on Phenomenex Luna® C18 column (5.0 μm particle size, 250 × 4.6 mm id) using a gradient mobile phase A (phosphate buffer pH 3.0) and mobile phase B (acetonitrile) at the working temperature of 25°C. The buffer was 1.11 g KH2PO4 with 1.2 g sodium pentanesulfonate/L of the solution, adjusted to pH 3.0 with orthophosphoric acid. The flow rate was 1.0 mL/min. The detection was carried out at 215 nm using a diode array detector. The developed method was validated according to the International Conference on Harmonization (ICH) guidelines for specificity, limit of detection, limit of quantification, linearity, precision and robustness. The proposed method is convenient and reliable for the purity control in both raw materials and dosage forms.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.