Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  GEM detector
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In scientific research, precise control of high voltages is crucial, particularly in ion traps and Gas Electron Multiplier (GEM) de tectors. The Sinara open hardware project addresses this need by developing a dedicated high-voltage system. The project introduces an STM32-based DIOT system board and a High Voltage Supply Board (HVSUP_ISOL) designed for non-real-time applications, providing up to +/-6kV. The HVSUP_ISOL board is fully isolated, ensuring system safety, and offers dual-channel configuration with a shared common terminal for easy casca ding. The firmware based on the MQTT protocol enables users to remotely control various settings, and telemetry data provi des insights into the system’s operation.
PL
W badaniach naukowych precyzyjna kontrola wysokich napięć jest niezwykle istotna, zwłaszcza w pułapkach jonowych i de tektorach GEM (Gas Electron Multiplier). W ramach projektu Sinara, zaprojektowany został nowy dedykowany system ge neracji i kontroli wysokich napięć. Projekt wprowadza kartę systemową DIOT opartą na układzie STM32 oraz kartę zasi lania wysokonapięciowego (HVSUP_ISOL), przeznaczoną do zastosowań nie wymagających kontroli w czasie rzeczywistym, dostarczającą napięcia do +/-6kV. Karta HVSUP_ISOL jest w pełni izolowana, zapewniając bezpieczeństwo systemu, oraz oferuje konfigurację dwukanałową z wspólnym terminalem dla łatwego kaskadowania. Oprogramowanie oparte na protokole MQTT umożliwia użytkownikom zdalną kontrolę różnych ustawień, a dane telemetrii dostarczają informacji o działaniu systemu.
EN
The validation of the measurements quality after on-site diagnostic system installation is necessary in order to provide reliable data and output results. This topic is often neglected or not discussed in detail regarding measurement systems. In the paper recently installed system for soft X-ray measurements is described in introduction. The system is based on multichannel GEM detector and the data is collected and sent in special format to PC unit for further postprocessing. The unique feature of the system is the ability to compute final data based on raw data only. The raw data is selected upon algorithms by FPGA units. The FPGAs are connected to the analog frontend of the system and able to register all of the signals and collect the useful data. The interface used for data streaming is PCIe Gen2 x4 for each FPGA, therefore high throughput of the system is ensured. The paper then discusses the properties of the installation environment of the system and basic functionality mode. New features are described, both in theoretical and practical approach. New modes correspond to the data quality monitoring features implemented for the system, that provide extra information to the postprocessing stage and final algorithms. In the article is described also additional mode to perform hardware simulation of signals in a tokamak-like environment using FPGAs. The summary describes the implemented features of the data quality monitoring features and additional modes of the system.
PL
Przedstawiono autorską koncepcję architektury sekwencjonowania danych pomiarowych o dużej częstości, odbieranych z wielokanałowych układów detekcyjnych w czasie rzeczywistym. Na wstępie omówiono genezę pracy w odniesieniu do rozwoju rozwiązań systemów pomiarowych z równoległym przetwarzaniem danych. Wskazano na najważniejsze korzyści wynikające z zastosowania układu sekwencera. Przeprowadzono dyskusję proponowanej architektury oraz omówiono realizację modelu w języku Matlab w celu doboru parametrów użytkowych implementowanych rozwiązań. Przedstawiono implementację architektury układu sekwencera w systemie diagnostyki gorącej plazmy w tokamaku WEST.
EN
This paper describes developed architecture of the sequencer dedicated for high rate measurement data collected from multiple channels in real time. Introduction presents a brief description and genesis of the project and its achievements in relation to presently existing and used measurements system where parallel data processing is crucial. Authors point out advantages of the developed architecture. Additionally is discussed model of the architecture realized in MATLAB environment in order to select most optimal parameters adjusted to specific processes. Last sections presents implementation of the sequencer architecture in plasma diagnostics measurement system for WEST tokamak.
EN
Based on the publications regarding new or recent measurement systems for the tokamak plasma experiments, it can be found that the monitoring and quality validation of input signals for the computation stage is done in different, often simple, ways. In the paper is described the unique approach to implement the novel evaluation and data quality monitoring (EDQM) model for use in various measurement systems. The adaptation of the model is made for the GEM-based soft X-ray measurement system FPGA-based. The EDQM elements has been connected to the base firmware using PCI-E DMA real-time data streaming with minimal modification. As additional storage, on-board DDR3 memory has been used. Description of implemented elements is provided, along with designed data processing tools and advanced simulation environment based on Questa software.
5
EN
Soft X-ray (SXR) plasma measurements are important type of diagnostics especially in tokamak facilities. Main output products are energy and topology spectra distributed in time. In case of Gas Electron Multiplier (GEM) detectors, used as radiation sensors, large number of analog readout channels must be provided. For this purpose Field-Programmable Gate Arrays (FPGAs) are used. Data quality monitoring (DQM) is important topic in case of asynchronous events registered by the measurement unit. Due to numerous FPGAs used it is necessary to provide advanced trigger synchronization between them. In the paper is proposed an algorithmic approach for the trigger link training and diagnostics. It is a key component in order to provide consistent measurement data for DQM analysis. The contents of the article covers the plasma experiments and related DQM topics. In following chapters explanation of the synchronization problem is described. The proposed algorithm will be used for trigger link synchronization and diagnostics aspects. The simulations are also discussed. Currently, the proposed ideas are at the stage of implementation and tests on real hardware. Simulation were successfully performed. Summary of the work carried out is presented at the end of the paper.
6
Content available Into the fast tomographic postprocessing in tokamaks
EN
The collaboration of authors led to implementing advanced and fast systems for diagnostics of plasma content in tokamaks. During the development of systems it is planned to add new functionalities, in particular, the algorithms of tomographic reconstruction to obtain information on three dimensional distribution of plasma impurities. In the article the idea of tomographic reconstruction is introduced and issues of performance and adequate hardware selection are presented.
PL
Wieloletnia współpraca autorów przyczyniła się do powstania zaawansowanych, szybkich mechanizmów diagnostyki składu gorącej plazmy tokamakowej. W ramach rozbudowy systemów zamierza wprowadzić się szereg nowych funkcjonalności, w tym algorytmy rekonstrukcji tomograficznej. Pozwoli to na uzyskanie informacji o przestrzennym rozkładzie nieczystości plazmy w reaktorze. Praca przedstawia koncepcję tomografii tego typu oraz przeprowadzona jest dyskusja nad zagadnieniami wydajności i doboru sprzętu.
PL
W artykule przedstawiono opracowane przez Zespół Autorów systemy szeregowania danych przychodzących z wielu źródeł w czasie rzeczywistym. Na wstępie krótko omówiono zasadę działania detektorów GEM wykorzystywanych do rejestracji promieniowania w tokamakach. Przedstawiono ogólnie budowę systemu do realizacji diagnostyki gorącej plazmy, działającego z dużą liczbą kanałów wejściowych. Szczegółowo omówiono system szeregowania danych. Przedstawiono wymagania algorytmu, opracowane koncepcje, napotkane problemy oraz implementacje algorytmów w układach FPGA. Dodatkowo przedstawiono przykładowe wyniki z działania systemu.
EN
This paper presents designed by the Research Team high performance sorting algorithms working in real time, for data coming from many concurrent sources. The introduction is a brief description of the basics of the GEM detectors, used for tokamaks’ radiation registration. In the paper is discussed the general design structure of electronic systems working with high number of input channels. In the article is described fast data processing, with focus on algorithms implemented in FPGA. Description covers in detail aspects of sorting algorithm. The article presents requirements of the algorithm, concepts, problems and implementation in the FPGA. The measurement result of the systems are also briefly discussed.
PL
W artykule przedstawiono opracowany przez Zespół Autorów system zabezpieczeń i diagnostyki dla detektora gazowego GEM. Na wstępie krótko omówiono zagrożenia na jakie narażony jest detektor GEM oraz elektroniczne systemy pomiarowe pracujące w bliskiej odległości od reaktora termojądrowego. Przedstawiono koncepcje modułu do ciągłego monitorowania stanu systemu do diagnostyki gorącej plazm. Pod względem bezpieczeństwa omówiono dwa kluczowe podsystemy: moduł zabezpieczeń i system chłodzenia cieczą. Opisano funkcjonalność systemu, przyjęte rozwiązania sprzętowe oraz implementacją oprogramowania. Na końcu przedstawiono praktyczne wykorzystanie systemu.
EN
This paper presents designed by the Research Team electronic protection and diagnostic system for GEM detectors. The introduction is a brief description of the hazards to which GEM detector and electronic measurement system operating close to fusion reactor are exposed. The concept of an electronic module for continuous monitoring of the state of the system for plasma hot plasma is presented. Two main safety subsystem are described: security module and liquid cooling system. Description cover aspects of system functionality, hardware construction and implemented firmware. Finally, the practical use of the system is presented.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.