Introduction: It is necessary to have special experience to perform the Monte Carlo calculation, commonly used in medical physics and accepted as the gold standard. In this study, we developed software to teach basic steps to medical physicists who were inexperienced in the medical linear accelerator Monte Carlo simulation. Material and methods: For the design interface, a software called GamosLinacGUI was developed using Gnome Builder, Python, and GTK. The user, who wants to learn the basics of GAMOS and simulate a linear accelerator, can enter the values in the software, select some options and quickly create geometry and physics files. Results: For proof that the software generates the correct inputs for GAMOS simulation in the same conditions for the measurements and calculations. Required files for GAMOS have been created and tested and run the simulation accordingly. This software was tested with Centos Linux. Conclusions: GamosLinacGUI has been successfully developed, which creates the geometry and physics files required for the simulation with GAMOS as a training and learning tool.
EN
Introduction: The limit of the method of calculating organ doses using voxelised phantoms with a Monte Carlo simulation code is that dose calculation errors in the boundaries of the organs are especially relevant for thin, small or complex geometries. In this report, we describe a tool that helps overcome this problem, accurately calculating organ doses by applying the “parallel geometry” utility feature of Geant4 through the GAMOS framework. Methods and methods: We have tried to simplify the use of this tool by automatically processing the different DICOM image modalities (CT, PT, ST, NM), and by including the automatic conversion of the structures found in a DICOM RTSTRUCT file into Geant4 volumes that build the parallel geometry. For Nuclear Medicine applications, the DICOM PT, ST or NM images are converted into probabilities of generation of primary particles in each voxel, and the DICOM CT images into materials and material densities. For radiotherapy treatments, the DICOM RTPlan or RTIonPlan may also be used, hence the user only needs to describe the accelerator geometry. We also provide a Graphical User Interface for ease of use by for inexperienced users in Monte Carlo. Results: We have tested the functionality of the tool with an I-131 thyroid cancer treatment, and obtained the expected energy deposition and dose differences, given that the particle source, geometry and structures are defined. Conclusions: In summary, we provide an easy-to-use tool to calculate, with high accuracy, organ doses, taking into account their exact geometry as painted by the medical personnel on a voxelised phantom.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.