Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 38

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  FDS
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
Due to the special structures and geographical environments of the main transport roadway of underground coal mines, it is difficult to deal with accidents and rescues in cases of fire and it is easy to cause casualties and structural damage of the roadway. In this study, a roadway fire model was established using FDS software on the basis of theoretical analysis. The smoke diffusion, temperature distribution, and CO concentration distribution in a fire period were simulated under four working conditions. The results showed that the time required for the smoke layer to descend to human breathing height was positively correlated with the distance between the position and the fire source. Under the most unfavorable conditions, the smoke reached human breathing height at 15.11 s and 100 m away from the fire source. After the fire broke out, the ambient temperature in the roadway rose rapidly, and the highest temperature in the area adjacent to the fire source reached 340 ℃. The farther away from the fire source, the lower the temperature, but it was still higher than the human body's optimum temperature (25 ℃) until 200 m away. The results of this study can provide a basis for the preparation of roadway fire emergency plans.
2
Content available remote Numerical study of conditions on the staircase during a fire in a public building
EN
Fire is one of the most common risks to the environment and human health. Fire, depending on the conditions of combustion and the type of fuel, can emit many toxic products. The paper presents numerical analyzes of the conditions that can occur in a building during a fire. The conditions were analyzed in terms of the safety of the occupants and possible emissions of pollutants into the atmosphere. The temperature, propagation of smoke, and emission of pollutants were analyzed. A numerical model was created using Fire Dynamics Simulator (FDS) software. The model represents a staircase and a corridor in a real building located at the Silesian University of Technology in Poland. The results show that safe conditions are only ensured for a limited time, and emissions can also be harmful to occupants and the environment.
PL
W artykule przedstawiono porównanie temperatur oddziałujących na wentylatory wyciągowe dla różnych koncepcji systemów oddymiania i odprowadzania ciepła z przestrzeni objętej pożarem. Zaprojektowane systemy mają za zadanie: zapewnić odpowiednie warunki ewakuacji ludzi z zagrożonej przestrzeni, umożliwić bezpieczne prowadzenie akcji ratowniczo- gaśniczej, zmniejszyć straty materialne oraz zapobiec rozprzestrzenianiu się pożaru. Zastosowanie metod numerycznych obliczeniowej dynamiki płynów do analizy temperatury w wentylacji pożarowej daje możliwość odwzorowania wpływu warunków środowiskowych na działanie systemu oraz porównania różnych koncepcji realizacji systemów na etapie projektowania. W związku z tym w niniejszej pracy porównano 9 przykładowych rozwiązań rozmieszczenia wentylatorów wyciągowych pod kątem oceny klasy odporności temperaturowej wentylatorów wyciągowych. Dla wszystkich scenariuszy średnia temperatura oddziałująca na wentylatory wyciągowe nie przekraczała 300 ⁰C, przy czym w najbardziej skrajnych przypadkach różnica temperatur przekraczała 100 ⁰C. Zaobserwowano duże różnice średniej temperatury w poszczególnych punktach pomiarowych, spowodowane różną geometrią otworów odprowadzających dym i gorące gazy pożarowe z przestrzeni pożarowej. Spowodowane są one również zastosowaniem modelu turbulencji LES, w którym z większą starannością odwzorowane są fluktuacje parametrów wynikające z przebiegu pożaru. Wykorzystanie numerycznych metod obliczeniowej dynamiki płynów do analizy temperatury daje również możliwość oceny klasy odporności temperaturowej innych elementów wentylacji pożarowej, takich jak przewody dymowe, klapy przeciwpożarowe czy kurtyny dymowe. Oszacowanie temperatury metodami obliczeniowej dynamiki płynów jest przybliżeniem rzeczywistości umożliwiającym analizę wpływu wielu czynników, dlatego może stanowić istotną pomoc dla projektantów systemów wentylacji pożarowej w doborze odpowiedniej klasy odporności temperaturowej wentylatorów wyciągowych.
EN
The article presents a comparison of temperatures affecting the exhaust fans for different concepts of smoke and heat extraction systems from the space covered by the fire. Designed systems are intended to: provide adequate conditions for evacuation of people from the endangered space, enable safe rescue and firefighting, reduce material losses and prevent the spread of fire. The use of numerical methods of computational fluid dynamics for temperature analysis in fire ventilation gives the possibility to map the impact of environmental conditions on the system operation and to compare different concepts of systems implementation at the design stage. As a result, this paper compares 9 sample exhaust fan placement solutions with respect to evaluating the temperature resistance class of the exhaust fans. For all scenarios, the average temperature affecting the exhaust fans did not exceed 300 ⁰ C, with a difference in temperatures exceeding 100 ⁰ C in the most extreme cases. Large differences in average temperature in individual measuring points were observed, caused by different geometry of openings leading away smoke and hot fire gases from the fire space. Caused also by application of LES turbulence model, in which fluctuations of parameters resulting from the course of fire are represented with more care. The use of numerical methods of computational fluid dynamics for temperature analysis gives also the possibility to evaluate the temperature resistance class of other fire ventilation elements such as smoke ducts, fire dampers or smoke curtains. Temperature estimation with the use of computational fluid dynamics methods is an approximation of reality enabling to analyze the influence of many factors, so it can be a significant help for designers of fire ventilation systems in the selection of appropriate temperature resistance class of exhaust fans.
4
Content available remote Modelowanie wpływu warunków środowiska pożarowego na dostępny czas ewakuacji
PL
W artykule przedstawiono analizę numeryczną wpływu czynników towarzyszących występowaniu pożaru na dostępny czas ewakuacji, na podstawie przyjętego scenariusza pożarowego w wybranym pomieszczeniu. Środowisko pożaru modelowano za pomocą zaawansowanych metod numerycznych CFD w programie FDS. Na podstawie wartości krytycznej zasięgu widzialności określony został czas, po którym użytkownicy nie byli w stanie ewakuować się z analizowanego pomieszczenia objętego pożarem w sposób bezpieczny dla ich zdrowia i życia. Dokonano oceny potencjału aplikacyjnego oprogramowania FDS do przeprowadzenia analiz związanych z wpływem warunków pożaru na dostępny czas ewakuacji w obiekcie.
EN
In the article a numerical analysis of the influence of factors accompanying the occurrence of fire for the available evacuation time was presented, based on the adopted fire scenario in a selected room. The fire environment modeling was performed using advanced numerical methods CFD in the FDS software. On the basis of the critical value of the visibility range, the time after which the users were not able to evacuate from the analyzed room under fire in a safe manner for their health and life was determined. The application potential of the FDS software was assessed for carrying out analyzes related to the impact of fire conditions on the available evacuation time in the facility.
PL
W niniejszym artykule zaprezentowano możliwości opracowanych modeli rozwoju pożaru i działania tryskaczy, które są dostępne w programie Fire Dynamics Simulator. Przedstawiono teoretyczny przykład analizy komputerowej z wykorzystaniem eksperymentalnych modeli pirolizy i gaszenia wodą. Jednym z najbardziej istotnych czynników mających wpływ na wyniki analizy komputerowej bezpieczeństwa budynku ma uzyskana w modelu szybkość uwalniania ciepła (z ang. Heat Release Rate, HRR). W oprogramówaniu komputerowym może być ona definiowana na wiele sposobów. Można skorzystać z podstawowej metody, czyli wprowadzić określoną wartość HRR, niezależną od warunków symulacji. Bardziej zaawansowany sposób to wyliczanie HRR z modelu poprzez symulowanie procesów pirolizy. Wybór metody modelowania HRR definiuje również możliwości w zakresie modelowania efektów gaszenia wodą. Modelowanie tłumienia ognia przez wodę musi uwzględniać opis trzech zjawisk: transport kropelek wody w powietrzu, przepływ wody wzdłuż stałej powierzchni oraz przewidywanie zmniejszenia się szybkości spalania. Podstawowy sposób to modyfikacja szybkości uwalniania ciepła lub założenie ograniczonej powierzchni pożaru. Bardziej zaawansowane metody pozwalają na modelowanie fazy gaszenia przez program, w zależności od ilości wody, która dociera do strefy spalania.
EN
This article describes possibilities offered by the existing fire spread and fire suppression models available in the Fire Dynamics Simulator. A theoretical example was provided of a computer analysis using experimental models of pyrolysis and sprinkler models. One of the most important factors that affect results of building safety computer analysis if the heat release rate (HRR) obtained in the model. It may be defined in many ways in computer programmes. Use may be made of the basic method, i.e. a defined value of HRR may be entered, independently of simulation conditions. A more advanced method comprises calculation of HRR from the model by simulating pyrolysis processes. Selection of a method for modelling HRR also defines possibilities related to modelling effects of water suppression. Modelling fire suppression by water must take into account three most important elements: moving of water droplets through the air, transporting the water along the solid surface, and predicting the decreasing of the burning rate. The basic method is to modify HRR curve. More advanced methods allow the user to model decay phase depending on amount of water which reaches fire area.
EN
This article describes possibilities offered by the existing fire spread and fire suppression models available in the Fire Dynamics Simulator. A theoretical example was provided of a computer analysis using experimental models of pyrolysis and sprinkler models. One of the most important factors that affect results of building safety computer analysis if the heat release rate (HRR) obtained in the model. It may be defined in many ways in computer programmes. Use may be made of the basic method, i.e. a defined value of HRR may be entered, independently of simulation conditions. A more advanced method comprises calculation of HRR from the model by simulating pyrolysis processes. Selection of a method for modelling HRR also defines possibilities related to modelling effects of water suppression. Modelling fire suppression by water must take into account three most important elements: moving of water droplets through the air, transporting the water along the solid surface, and predicting the decreasing of the burning rate. The basic method is to modify HRR curve. More advanced methods allow the user to model decay phase depending on amount of water which reaches fire area.
PL
W niniejszym artykule zaprezentowano możliwości opracowanych modeli rozwoju pożaru i działania tryskaczy, które są dostępne w programie Fire Dynamics Simulator. Przedstawiono teoretyczny przykład analizy komputerowej z wykorzystaniem eksperymentalnych modeli pirolizy i gaszenia wodą. Jednym z najbardziej istotnych czynników mających wpływ na wyniki analizy komputerowej bezpieczeństwa budynku ma uzyskana w modelu szybkość uwalniania ciepła (z ang. Heat Release Rate, HRR). W oprogramówaniu komputerowym może być ona definiowana na wiele sposobów. Można skorzystać z podstawowej metody, czyli wprowadzić określoną wartość HRR, niezależną od warunków symulacji. Bardziej zaawansowany sposób to wyliczanie HRR z modelu poprzez symulowanie procesów pirolizy. Wybór metody modelowania HRR definiuje również możliwości w zakresie modelowania efektów gaszenia wodą. Modelowanie tłumienia ognia przez wodę musi uwzględniać opis trzech zjawisk: transport kropelek wody w powietrzu, przepływ wody wzdłuż stałej powierzchni oraz przewidywanie zmniejszenia się szybkości spalania. Podstawowy sposób to modyfikacja szybkości uwalniania ciepła lub założenie ograniczonej powierzchni pożaru. Bardziej zaawansowane metody pozwalają na modelowanie fazy gaszenia przez program, w zależności od ilości wody, która dociera do strefy spalania.
7
Content available remote Numerical studies on the natural smoke venting of atria
EN
The use of numerical fluid mechanics to model smoke flow in buildings where a fire develops is common. It allows to check the effectiveness of ventilation systems at the design stage. It also gives the opportunity to determine the conditions that will be on escape routes. Numerical analyzes of smoke flow in buildings are most often performed using Fire Dynamics Simulator (FDS). The paper presents numerical analyzes performed for the atrium building. The purpose of the calculations was to build a numerical model that corresponds to the real object located in the laboratory in Murcia, Spain. The analyzes consisted of fitting a numerical model based on the temperature distribution at selected points of the atrium. The model mapped the geometry of the real building and assumed the same fire power. Calculations showed high temperature compliance throughout the atrium, except for the vicinity of the fire source itself.
PL
Niniejsza publikacja dotyczy rozpoznania wpływu temperatury na parametry relaksacji dielektrycznej izolacji złożonej z papieru aramidowego (Nomex) impregnowanego estrem syntetycznym (Midel 7131). Procesy relaksacyjne badano metodą FDS (Frequency Domain Spectroscopy). Do wykonania pomiarów użyto systemu DIRANA OMICRON. Do prezentacji i analizy wyników pomiarów wykorzystano program Origin v.8.0 oraz WinFit firmy Novocontrol. Do wyznaczenia podstawowych parametrów funkcji relaksacyjnych zastosowano uogólnione równanie Havriliaka-Negamiego.
EN
This publication deals with the recognition of the influence of temperature on dielectric relaxation parameters of insulation based on aramid paper (Nomex) impregnated with synthetic ester (Midel 7131). Relaxation processes were investigated by FDS (Frequency Domain Spectroscopy). DIRANA OMICRON system was used for the measurements, while Origin v.8.0 and Novocontrol WinFit were used to present and analyze measurement results. The generalized Havriliak-Negami equation was used to determine the basic parameters of the relaxation functions.
9
Content available remote Odpowiedź dielektryczna papieru aramidowego impregnowanego estrem syntetycznym
PL
Niniejsza publikacja zawiera badania odpowiedzi dielektrycznej papieru aramidowego (Nomex) impregnowanego estrem syntetycznym (Midel 7131) w różnej temperaturze i zawilgoceniu. Procesy relaksacyjne badano metodami FDS (Frequency Domain Spectroscopy) oraz PDC (Polarization Depolarization Current). Do wykonania pomiarów użyto systemu DIRANA OMICRON oraz miernika Keithley 6517A. Do prezentacji i analizy wyników pomiarów wykorzystano program Origin v.8.0 oraz WinFit firmy Novocontrol. Do wyznaczenia podstawowych parametrów funkcji relaksacyjnych zastosowano uogólnione równanie Havriliaka-Negamiego oraz zależność Jonschera LFD.
EN
This publication deals with the recognition of the influence of temperature and moisture on dielectric relaxation parameters of insulation based on aramid paper impregnated with synthetic ester (Midel 7131). Relaxation processes were investigated by FDS (Frequency Domain Spectroscopy) and PDC (Polarization Depolarization Current). DIRANA OMICRON and Keithley 6517A system was used for the measurements, while Origin v.8.0 and Novocontrol WinFit were used to analyze measurement results. The generalized Havriliak-Negami and Jonscher LFD equation was used to determine the relaxation functions.
10
Content available remote Dielectric response of oil impregnated Nomex in frequency and time domain
EN
Nomex has been introduced to electrotechnical industry, mainly as high voltage insulating material, used for example in power transformers. The aim of this paper is to identify the influence of moisture on dielectric relaxation of solid-liquid insulation consisting of Nomex impregnated with transformer oil. From practical measurements a series of FDS (Frequency Domain Spectroscopy) and PDC (Polarization Depolarization Current) characteristics were obtained for Nomex-oil insulating system.
PL
Nomex znalazł ważne zastosowanie w branży elektrotechnicznej, głównie jako wysokonapięciowy materiał izolacyjny stosowany w transformatorach energetycznych. Niniejsza publikacja dotyczy rozpoznania wpływu zawilgocenia na relaksację dielektryczną stało-ciekłej izolacji złożonej z Nomexu impregnowanego olejem transformatorowym na podstawie pomiarów metodą spektroskopii dielektrycznej FDS (Frequency Domain Spectroscopy) oraz rejestracji pradów polaryzacji i depolaryzacji PDC (Polarization Depolarization Current).
EN
Real scale fire experiments involve considerable costs compared to computational mathematical modelling. This paper-work is the result of such a virtual simulation of a fire occurred in a hypothetical wholesale warehouse comprising a large number of trade stands. The analysis starts from the ignition source located inside a trade stand towards the fire expansion over three groups of compartments, by highlighting the heat transfer, both in small spaces, as well as over large distances. In order to confirm the accuracy of the simulation, the obtained values are compared to the ones from the specialized literature.
PL
Pełnoskalowe eksperymenty pożarnicze wymagają poniesienia znacznych kosztów w porównaniu z matematycznymi symulacjami obliczeniowymi. Niniejszy artykuł jest wynikiem takiego wirtualnego pożaru, który wybuchł w hipotetycznym pomieszczeniu magazynowym, w którym znajduje się wiele regałów z towarami. Zapłon nastąpił w źródle zlokalizowanym wewnątrz regału, a rozwój pożaru nastąpił w stronę trzech przedziałów. Analizie poddano również przepływ ciepła, zarówno w małych, jak i większych pomieszczaniach oraz na różne odległości. Aby potwierdzić dokładność symulacji, uzyskane wartości obliczeniowe porównano z wynikami podanymi w piśmiennictwie.
EN
The article presents a method allowing one to validate repeatability of cellulose-oil insulation samples laboratory test results. The laboratory tests were conducted by means of frequency domain spectroscopy (FDS).
13
Content available remote Wpływ morfologii kompozytu RBP na odpowiedz dielektryczną
PL
W artykule zaprezentowano rozpoznanie efektów procesu starzeniowego w izolacji główniej przepustów RBP na podstawie odpowiedzi dielektrycznych poszczególnych warstw izolacji. Skupiono się na metodzie FDS w celu określenia możliwych zmian morfologicznych izolacji w zależności od miejsca pobrania próbek.
EN
The paper presents the recognition of effects of aging in isolation bushings RBP mainly based on the dielectric response of the individual layers of insulation. The focus is on the method of FDS to identify possible morphological changes of insulation, depending on the place of sampling.
PL
W artykule zaprezentowano pomiary metodą FDS (Frequency Domain Spectroscopy) izolacji epoksy-mika-szkło poddanej długotrwałemu działaniu temperatury z zakresu 150160 0C. Analizę danych pomiarowych przeprowadzono za pomocą zależności Havriliaka- Negamiego. Wykazano, że metoda FDS może stanowić miarodajne narzędzie diagnostyczne izolacji epoksy-mika-szkło na etapie produkcji jak i eksploatacji.
EN
The paper presents measurements conducted with FDS (Frequency Domain Spectroscopy) method on epoxy-mica-glass insulation exposed to long term temperature influence in the range 150160 0C. The analysis of measured data has been performed with Havriliak-Negami equation. It was showed that FDS method can be a reliable diagnostic tool for epoxy-mica-glass insulation, both in production and operation.
PL
Artykuł przedstawia wyniki analizy zawilgocenia wybranych typów transformatorów. Przeanalizowano w nim wpływ wieku izolacji stałej transformatorów typu RTdxP oraz ANER na poziom jej zawilgocenia. Analizie poddano również wpływ sposobu zabezpieczania transformatorów przed wnikaniem wilgoci z powietrza na zawilgocenie izolacji stałej oraz rozstęp wyników.
EN
The article presents the analysis of moisture content for the selected transformer types. Authors analyze the influence of the age of solid insulation of transformer type RTdxP and ANER on its water content level. Authors also analyzed the influence of the method used for transformer protection against the moisture penetration on solid insulation moistening results.
PL
W artykule zaprezentowano pomiary metodą FDS (Frequency Domain Spectroscopy) impregnowanego olejem transformatorowym Nomexu. Analizę jakościową procesów relaksacyjnych przeprowadzono za pomocą zależności Havriliaka-Negamiego. Badania wykazały, że szacowanie zawilgocenia Nomexu za pomocą metody FDS może być utrudnione w zakresie zawilgocenia 1-3%.
EN
The paper presents results of measurements of FDS method (Frequency Domain Spectroscopy) of Nomex impregnated with transformer oil. The qualitative analysis was conducted with Havriliak-Negami equation. The research has showed that moisture contents assessment with FDS method may be difficult for values in the range 1-3%.
17
Content available remote Nowoczesne metody diagnostyczne wysokonapięciowych przepustów transformatorowych
PL
W artykule zaprezentowano przegląd nowoczesnych metod diagnostycznych transformatorowych przepustów wysokiego napięcia. Główną uwagę skupiono na metodach: termowizyjnej i spektroskopii dielektrycznej FDS. Zaprezentowano badania laboratoryjne i terenowe oraz sposób interpretacji wyników pomiarów.
EN
This article presents an overview of new diagnostic methods of high voltage transformer bushings. The main attention is focused on the methods: thermovision and dielectric spectroscopy FDS. Presents field and laboratory testing and interpretation of results.
PL
W artykule zaprezentowano pomiary PDC (Polarization Depolarization Current). impregnowanego olejem transformatorowym Nomexu o różnym zawilgoceniu. Analizę jakościową procesów relaksacyjnych przeprowadzono za pomocą aproksymacji pradów polaryzacji funkcją Jonschera LFD. Badania wykazały, że szacowanie zawilgocenia Nomexu za pomocą metody PDC może być utrudnione dla zawartości wody 1 3,5%. Następnie wyniki badań zweryfikowano z wynikami pomiaru metodą FDS (Frequency Domain Spectroscopy).
EN
Nomex has been introduced to electrotechnical industry mainly as a high voltage insulating material, used for example in power transformers. The aim of this paper is to identify the influence of moisture on dielectric relaxation of solid-liquid insulation consisting of Nomex impregnated with transformer oil. To perform such research, there was constructed a special measurement set-up with steel electrodes 20x20 cm large. A sheet of Nomex 410, 0.76 mm thick, was placed between these electrodes. The required values of moisture level were achieved by drying Nomex at 150°C in a laboratory vacuum chamber or through moisturization in a Feutron climate chamber at the relative air humidity 90% and the temperature 24°C. The moisture level was estimated on the basis of measurements of weight changes. Relaxation processes were measured with the PDC method (Polarization Depolarization Current). The research showed that assessment of the moisture content with the PDC method can be difficult for the values from the range 1-3%. The experimental results were verified with FDS (Frequency Domain Spectroscopy) measurements. The analysis of the relaxation process of oil impregnated Nomex showed that: a) water content in Nomex results in significant increase in dielectric losses, which seems to be caused by water particles, b) in the moisture range 1-3% dielectric response of Nomex is practically the same and does not depend on the moisture level. The same effect was observed for both relaxation process and conductivity, c) for the water content above 3-3,5% there is a rapid increase in the conductivity and dielectric losses. It is probably due to the exceeding percolation threshold of water particles gathered between aramid fibres.
PL
W artykule zaprezentowano wyniki badań wpływu starzenia termicznego w warunkach zbliżonych do eksploatacyjnych na odpowiedź dielektryczną izolacji przepustu RBP. Stwierdzono, że pomiary wykonane dla dużego gradientu temperatury w izolacji stwarzają możliwość zaobserwowania relaksacji warstw położonych w okolicy toru prądowego. Natomiast pomiary wykonane dla stałej temperatury dają sumaryczną odpowiedź całej objętości izolacji. Analiza jakościowa odpowiedzi dielektrycznej przepustu z zastosowaniem równania H-N wykazała istnienie procesów polaryzacyjnych w zakresie niskich częstotliwości, których stałe czasowe zależą od stopnia zestarzenia izolacji i gradientu temperatury po promieniu rdzenia.
EN
The paper presents results of the research on influence of thermal ageing under conditions similar to the operating ones on the dielectric response of RBP bushing insulation. The thermal ageing of insulation under operating conditions was simulated by increasing the temperature of a bushing conductor to T = 800C, at constant ambient temperature T ≈ 10÷12 ºC. Measurements of tgδ and capacitance were taken with the FDS method at various temperatures of the conductor. The analysis of the test results showed that thermal ageing led to the shortening of time constants of polarization processes. It was found that the measurements taken for a large gradient of the temperature in insulation allowed observation of its relaxation for layers located near the conductor. The measurements taken for a constant temperature gave the cumulative response of the whole insulation capacity. The qualitative analysis of the bushing dielectric response with the H-N equation showed existence of polarization processes in the low frequency range, with time constants depending on the insulation ageing level and the temperature gradient along the core radius.
PL
W niniejszym opracowaniu przedstawiono analizę i opis kilku narzędzi, programów do komputerowego modelowania procesów logistycznych (planowania i prognozowania) zachodzących w tunelach komunikacyjnych zjawisk, takich jak, na przykład, przepływy powietrza, pożary, ewakuacja w tunelach komunikacyjnych podczas pożaru. Znajomość oprogramowań umożliwiających umiejętne przewidywanie (modelowanie) różnych zjawisk i procesów takich jak: zachowania ludzi w przypadku sytuacji awaryjnej, czy też wypadki, z których bez wątpienia najgroźniejsze są pożary, przy jednoczesnym zachowaniu specyfiki obiektu jest niezwykle istotna, zwłaszcza na etapie projektowania tunelu.
EN
This paper presents an analysis of some tools and programs to computer modeling of phenomena and processes taking place in the tunnels during communication such as the flow of air, fire, evacuation during fire, etc. Knowledge of software to enable confident prediction (modeling) of various phenomena and processes such as human behavior during accident or fire is extremely important, especially in the design phase.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.