The article contains general information about the modernization process of the circulating water pumping station at the PGE Lublin-Wrotków CHP Plant, in which the most important part was the modernization of the PWS6 pump drive, finished in December 2007. The two-year long operation of the modernized pumping station let us estimate the achieved savings in electricity consumption, just as the financial and environmental effects. The achieved results were estimated in comparison to the values which were supposed before the ultimate decision of the modernization.
EN
The article contains general information about the modernization of the PWS6 pump drive with respect the whole modernization process of the circulating water pumping station at the Lublin-Wrotków CHP Plant. The circulating water pumping station is the biggest system at the plant, with the total installed power demand of 5,8 MW. It includes seven pumps (three pumps type 35W50 and four modernized pumps type 35W50M). The pumps operate in parallel and supply a common collector for the demand of the Lublin District Heating System. Two pumps are controlled by regulation of rotary speed one by means of frequency converter and the next one through a sub-synchronic cascade system. At present, the system is overloaded (in terms of hydraulic) with one or two controlled pumps, or three pumps while one pump has no control. In order to keep the system supply parameters the non-controlled pump must be throttled. Modernized PWS6 pump (new motor and frequency converter) lets replace a non-controlled pump (in case of three pumps operation) or the pump controlled through a cascade system (in case of two pumps operation). As a result, the system will operate without throttling losses. It is estimated that the achieved savings in electricity consumption will reach about 900 MWh per year. It implicates significant financial savings just as environmental effect (reduction of emissions).
PL
Rozwiązywanie problemów przeciażenia linii znajduje swe odniesienie w bezpiecznej pracy systemu elektroenergetycznego. Dotyczy to zarówno linii przesyłowych najwyższych napięć, jak i linii o napięciu 110kV łączących z reguły elektrociepłownie z systemem. Wychodząc z założenia ograniczonych możliwości przesyłowych tych linii, szukano niejednokrotnie najkorzystniejszych technicznie i ekonomicznie rozwiązań optymalizacyjnych w tym zakresie. Jedno z nich - sprawdzone w praktyce - jest przedstawione w ponizszym opracowaniu i może służyć, zdaniem autorów, jako przykład do zastosowania.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.