This study investigated the relationship between the parameters of the DLP manufacturing process and the structure of photopolymerizable acrylic resins. Four different process parameters were established to produce different thin-walled acrylic sample series: exposure time, layer thickness, area offset, and number of transition layers. The structure and the surface of the obtained samples were examined with the use of the FTIR–ATR method and an optical microscope, respectively. It was proved that extension of the exposure time increases the density of crosslinking and sample thickness. A decreasing crosslinking density due to rising layer thickness is observed. The area offset affects only the dimensions of the sample, predictably reducing the dimensions of the sample as the compensation increases. The absence of transition layers proved unfavorable in many respects, both structurally and geometrically.
PL
Zmodyfikowana wersja minispektrometru typu DPL NIR Scan została testowo zastosowana w laboratoriach oraz w warunkach mobilnych do analizy różnych materiałów. Jako testowa została wybrana seria obiektów badawczych w postaci głównie obiektów organicznych. Metoda pomiarowa i zastosowane urządzenie z powodzeniem może być zastosowane również do badania różnorodnych cienkowarstwowych materiałów półprzewodnikowych, ze względu na zakres pomiarowy. Badania wstępne już wykonane na innych obiektach, w tym z grupy materiałów stosowanych w elektronice, m.in. filmów półprzewodnikowych i nanokompozytowych, rokuje perspektywistyczność poszerzenia grupy obiektów pomiarowych też i na materiały z tej grupy. Za pomocą urządzenia można tworzyć bazy danych pomiarowych, które później mogą być wykorzystywane do diagnostyki badanych obiektów, w tym zmian w dziedzinie czasu lub na etapach obróbki technologicznej.
EN
A modified version of the DPL NIR Scan type mini-spectrometer was tested in laboratories and in mobile conditions for the analysis of various materials. A series of research objects in the form of mainly organic objects was chosen as the testing probes. The measuring method and the device used can also be successfully used for testing various thin-film semiconductor materials, due to the measuring range. Preliminary tests already performed on other objects, including from the group of materials used in electronics, among others semiconductor and nanocomposite films, promising the prospect of expanding the group of measurement objects also for materials from this group. Using the device, it is possible to create measurement databases that can later be used to diagnose the examined objects, including changes in the time domain or at the stages of technological processing.
PL
Celem pracy jest porównanie dawek otrzymywanych przez pacjentów dorosłych poddanych badaniom tomografii komputerowej głowy z poziomami dawek referencyjnych zawartymi w Rozporządzeniu Ministra Zdrowia. Do retrospektywnej analizy włączono 62 pacjentów, u których wykonano badanie tomografii komputerowej głowy techniką spiralną. Wszystkie badania wykonano przy użyciu tego samego protokołu. Uzyskano wyniki z pomiarów dawek w postaci parametrów: ważony tomograficzny indeks dawki (CTDIw) oraz iloczyn dawka-długość (DLP). Analizowane parametry dotyczyły tylko części diagnostycznej badania z wyłączeniem tzw. topogramu. Następnie porównano wyniki z poziomami dawek referencyjnych. Stwierdzono, iż dawki otrzymywane przez pacjentów poddanych badaniom tomografii komputerowej głowy nie przekraczają poziomów dawek referencyjnych, a protokół, przy użyciu którego wykonane zostały badania, zapewnia pacjentom w pełni akceptowalny poziom narażenia na promieniowanie jonizujące.
EN
The aim of this study is to compare radiation doses received by adult patients undergoing computerised tomography (CT) of the head with references to dose levels included under the regulations of the Minister of Health. For the retrospective analysis, 62 patients were enrolled in whom cranial CT had been performed using the spiral technique. All examinations were performed using the same protocol. Results from dose measurements were obtained in the form of Computed Tomography Dose Index weighted (CTDIw) and Dose Lenght Product (DLP) parameters. The analysed parameters concerned only the diagnostic part of the study, excluding the so-called “topogram”. The results were subsequently compared with the reference dose levels. It was found that the doses received by patients undergoing cranial CT do not exceed the maximum recommended levels, and the protocol by which the examinations were performed provides patients with a fully acceptable level of exposure to ionizing radiation.
PL
Artykuł zawiera ocenę jakości wydruku elementów wykonanych w technice druku DLP, poprzez analizę projekcji otrzymanych z tomografu wolumetrycznego i konwencjonalnego. Podczas analizy określono czy możliwym jest wykonanie fantomu do CBCT z wydruku światłoutwardzalnego przy pomocy drukarki DLP. Badania tomograficzne miały na celu określenie obecności wtrąceń materiałowych i pęcherzy powietrza, mogących dawać efekt odbicia promieni rentgenowskich. Przeanalizowano ilość pochłanianej wiązki promieniowania poprzez pomiary wartości jednostek Hounsfielda dla wielu obszarów próbek.
EN
The article has been devoted to an evaluation of the print quality of elements made in the DLP printing technique, which was obtained as a result of the analysis of the projection from the volumetric and conventional CT. During this analysis the presence of air bubbles, material inclusions and other artifacts, which may give the effect of X-ray reflection, was determined. The amount of absorbed radiation beam was also analysed by measuring the Hounsfield unit values for many sample areas.
5
EN
In normal conditions, the Critical Flicker Frequency is usually 60Hz. But in some special conditions, such as low spatial frequency and high contrast between frames, these special conditions have high probability to occur in some TPVM-based applications. So it’s extremely important to verify if a visual signal with a combination of temporal and spatial frequency can be recognize by human eyes. Based on the research in the last paper ’ ’Window of Visibility’ inspired security lighting system’, this paper introduces the measuring method of WoV of human eyes. In this paper we will measure critical flicker frequency in low spatial frequency and high contrast conditions, and we can witness a different conclusion from the normal conditions.
EN
The motivation of investigation is explained by the problem of keeping organisations’ information and private ones secure. One reason for this is insufficiency of information protection systems, and another – vulnerability in such kind of systems. The article is devoted to defining and analyzing the types and sources of information security threats for an automated system. It can be useful for developing the model method, having the purpose of detecting and further preventing of hazards. The safeness of Data Leak Prevention (DLP) system itself is also under investigation. The analysis was carried out by an expert method with system analysis. A DLP system was considered, on the one hand, as a way of information protection to prevent information leakage, and on the other hand, as an object of protection which is vulnerable to threats of information security. The presented threat model includes the sources of threats, divided into three large groups: anthropogenic, technogenic and spontaneous; and types of threats: intentional and unintentional.
7
Content available remote Zastosowanie metody Rapid Prototyping do wykonywania prototypowych obudów USB
PL
Przedmiotem pracy jest opracowanie prototypowych obudów USB. Wykonano prototyp obudowy metodą FDM (Fused Deposition Modeling) i przetestowano sposób jego montażu. Dla testowania cech użytkowych a w szczególności oddziaływania cieplnego wykonano model woskowy metodą DLP (Digital Light Processing) a następnie wykonano odlew ze stopu aluminium (AlSi7Mg). Testy w warunkach rzeczywistych wykazały przydatność użytkową konstrukcji odlewów.
EN
The subject of the work is to develop a prototype USB cases. A prototype cases was made by FDM method (Fused Deposition Modeling) and tested method of its installation for testing the functional characteristics and in particular the thermal impact were made wax model using DLP (Digital Light Processing)and then made a aluminum casting( AlSi7Mg) Tests in real conditions has shown use fullness of castings.
PL
W pracy zostały przedstawione wyniki badań doświadczalnych nad aplikacją metody bezpośredniego grawerowania laserowego w procesie wytwarzania mikroukładów tab on a chip. Badano wpływ mocy wiązki lasera, szybkości przesuwu głowicy oraz rozdzielczości grawerowania, na jakość uzyskanych struktur. Dzięki wykorzystaniu techniki DLP możliwe jest skrócenie czasu wytwarzania mikroukładu z kilkudziesięciu godzin do kilkunastu minut oraz obniżenie kosztów projektowania i fabrykacji układów LOC.
EN
Results of experimental investigations of the application of direct laser prototyping method (DLP) in the process of manufacturing lab-on-a-chip systems are presented in the paper. The effects of laser beam power, speed of laser head and engraving resolution on the quality of resulting structures were analyzed. Thanks to the use of DLP technique, it is possible to shorten the manufacturing time of microsystems from dozens of hours to a few minutes and to reduce costs of system design and fabrication.
9
PL
W artykule opisano projekt innowacyjnego urządzenia służącego do wyświetlania w trzech wymiarach obrazów medycznych. Dzięki zastosowaniu technologii cyfrowego przetwarzania światła DLP (Digital Light Processing) w połączeniu z logiką programowalną, urządzenie jest w stanie oszukać ludzkie oko i zmieniać wyświetlane obrazy z bardzo wysoką częstotliwością. Artykuł opisuje założenia projektu, jego konstrukcję, wykorzystane w nim technologie oraz specjalnie stworzone oprogramowanie. Urządzenie komunikuje się z komputerem osobistym za pomocą standardu HDMI (High-Definition Multimedia Interface), a na wejściu obsługuje informacje zapisane w formacie DICOM (Digital Imaging and Communications in Medicine).
EN
The design of an innovative device for displaying three- -dimensional medical images, was introduced in the paper. The device is able to fool a human eye and change the displayed images with very high frequency, by means of DLP (Digital Light Processing) technology, in combination with programmable logic. This paper describes the main design goals, used technology and specially designed software. The device communicates with the PC by means of HDMI (High-Definition Multimedia Interface) capabilities, and supports the input information stored in DICOM (Digital Imaging and Communications in Medicine) format.
10
Content available remote LCD, DLP planar lighting fitting
PL
Wyświetlacze LCD emitują strumień świetlny w sposób zbliżony do lambertowskiego i dodatkowo pozwalają na sterowanie rozkładem widmowym emitowanego promieniowania. Zaprezentowano koncepcję oprawy oświetleniowej umożliwiającej sterowanie ilością emitowanego strumienia świetlnego oraz zmianę parametrów kolorymetrycznych.
EN
The LCD displays emit the luminous flux similar to lambertian emission and additionally allow to control the spectral distribution. Conception of lighting fitting enabling the control of emitted luminous flux quantity and change of colorimetric parameters was presented.
11
Content available remote Pruning Operators for Disjunctive Logic Programming Systems
EN
Disjunctive Logic Programming (DLP) is an advanced formalism for knowledge representation and reasoning. The language of DLP is very expressive and supports the representation of problems of high computational complexity (specifically, all problems in the complexity class \SigmaP2 = \NP\NP). The DLP encoding of a large variety of problems is often very concise, simple, and elegant. In this paper, we explain the computational process commonly performed by DLP systems, with a focus on search space pruning, which is crucial for the efficiency of such systems. We present two suitable operators for pruning (Fitting's and Well-founded), discuss their peculiarities and differences with respect to efficiency and effectiveness. We design an intelligent strategy for combining the two operators, exploiting the advantages of both. We implement our approach in DLV - the state-of-the-art DLP system - and perform some experiments. These experiments show interesting results, and evidence how the choice of the pruning operator affects the performance of DLP systems.