EN
The article presents a new generation of ultra-fast hybrid switching systems (USH) for reliable, ultra-fast protection of various medium and low voltage DC systems (MVDC and LVDC). The DC switch-off takes place in a vacuum chamber (VC) cooperating with a semiconductor module using current commutation of natural or forced type. Against the background of the current state of science and technology, the paper depicts the basic scopes of USH applications and their particular suitability for operation in high magnetic energy DC circuits. In the case of DC system failures, this magnetic energy should be dissipated outside the system as soon as possible. Usually, magnetic blow-out switches (MBOS) with relatively low operating speed are used for this purpose. The article describes the theoretical basis and principles of construction of two types of novel USH systems: a direct current switching system (DCSS) and a direct current ultra-fast hybrid modular switch (DCU-HM). The DCSS family is designed for quench protection of superconducting electromagnets’ coils in all areas of application. The DCU-HM family is designed for the protection of all systems or vehicles of DC electrical traction and for related industrial applications. The conducted comparative analysis of the effectiveness of USH with respect to MBOS shows clear technical advantages of the new generation switching systems over MBOS. List of abbreviations used in the article is provided at the end.
EN
The article addresses the problem of short-circuits in DC circuits of high voltage direct current (HVDC) transmission systems. The current state of HVDC technology development, including achievable parameters of semiconductor components, relevant for short-circuit strength, are presented. The differences between voltage source converter (VSC HVDC) topologies are described from the perspective of affecting the possibilities of switching off short-circuit currents and the results of simulation tests for selected topologies are presented. Responses of a system with a cable and overhead line to ground-fault of one or both poles are analysed and compared. The results of the analysis have shown that short-circuits in the DC circuits of a VSC HVDC system cause a rapid and very significant increase in the short-circuit current, which imposes high requirements on DC breakers that are starting to appear in field applications.
PL
W artykule podjęto problem zwarć w obwodach DC układów przesyłowych prądu stałego na wysokim napięciu (HVDC). Przedstawiono aktualny stan rozwoju technologii HVDC, w tym osiągalne parametry elementów półprzewodnikowych, istotne z punktu widzenia wytrzymałości zwarciowej. Opisano różnice w topologiach przekształtników układów tranzystorowych (VSC HVDC) wpływające na możliwości wyłączania prądów zwarciowych oraz przedstawiono wyniki badań symulacyjnych dla wybra- nych z nich. Poddano analizie i porównano odpowiedzi układu z linią kablową i napowietrzną na zwarcie jednego bieguna lub obu biegunów do ziemi. Wyniki analiz pokazały, że zwarcia w obwodach prądu stałego układu VSC HVDC powodują szybki i bardzo znaczny wzrost prądu zwarciowego, co narzuca duże wymagania na wyłączniki DC, które dopiero zaczynają być w praktyce stosowane.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.