Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  Current Physical Components
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper shows how fixed-parameters reactive compensators in four-wire systems with a nonsinusoidal voltage can be converted into controlled-parameters compensators. Such compensators can serve as adaptive balancing compensators of reactive power of unbalanced loads. Thyristor switch inductors (TSIs) are used for such conversion. The fixed-parameters balancing reactive compensators are synthesized using the Currents’ Physical Components (CPC) – based power theory. The adaptive compensator is composed of two sub-compensators, one in the structure and the other in the structure. The method is illustrated with a numerical example and results of computer modeling of the load with a fixed-parameters and with an adaptive compensator.
PL
Artykuł pokazuje jak równoważący kompensator reaktancyjny prądu biernego, o sta łych parametrach, w systemach cztero- przewodowych, może być przekształcony w kompensator o parametrach kontrolowalnych. Kompensator taki może być użyty jako kompensator adaptacyjny. Przekształcenie takie umożliwiają włączane tyrystorami induktory (TSI). Parametry równowa żącego kompensator prądu biernego mogą być obliczone z pomocą teorii mocy opartej na Składowych Fizycznych Prądu (CPC). Kompensator jest zbudowany z dwóch sub-kompensatorów, z którch jeden ma strukturę X, a drugi strukturę Y. Przedstawiona w artykule metoda syntezy jest ilustrowana przykładami liczbowymi i rezultatami kompensacji.
2
Content available remote Critical comments on the Conservative Power Theory (CPT)
EN
Main features of the Conservative Power Theory (CPT) are examined in the paper. It was concluded that the “reactive energy” as defined in CPT cannot be regarded as a physical quantity. It was demonstrated that separation of the void reactive current can lead to wrong conclusions at a reactive compensator design. It was shown that distortion power defined in the CPT has no relation to mutual distortion of the load voltage and current. The meaning of the term “conservative” as used in the CPT, is discussed as well. It is emphasized that the conservative property of the “reactive energy” is only mathematical, but not physical property of that “energy”.
PL
W artykule przeanalizowano główne właściwości Zachowawczej Teorii Mocy (ang. Conservative Power Theory - CPT). Pokazano, że zdefiniowana w CPT „energia reaktancyjna” nie może być uważana za wielkość fizyczną. Pokazano, że wyodrębnienie z prądu odbiornika „prądu bezużytecznego” (ang.: „void current”) może prowadzić do błędnych wniosków odnośnie kompensacji reaktancyjnej, a ponadto, że zdefiniowana w CPT moc odkształcenia nie ma związku ze wzajemnym odkształceniem prądu i napięcia odbiornika. W artykule analizowane jest także znaczenie pojęcia „zachowawcza”, użytego w nazwie CPT. Pokazano, że „energia reaktancyjna” ma właściwość zachowawczą tylko w sensie matematycznym, lecz nie w sensie fizycznym.
3
Content available remote Working and Reflected Active Powers of Three Phase Loads
EN
Unbalanced and/or harmonic loads have to be supplied with a working active power which is higher than active power. The difference between the working active power and the common active power is referred to as the reflected active power. This reflected active power can be more visible in weaker power systems, such as micro-grids in islanded mode or on large industrial loads, such as pulsing loads or arc furnaces. The paper presents results of studies of the reflected active power on the relative short circuit power of the supply source.
PL
Odbiorniki niezrównoważone oraz odbiorniki generujące harmoniczne muszą być zasilane roboczą mocą czynną, która jest większa od mocy czynnej takich odbiorników. Różnica między roboczą mocą czynną a mocą czynną jest odbitą moca czynną. Odbita moc czynna może być szczególnie widoczna w słabych systemach rozdzielczych, takich jak w mikro-sieciach pracujących w warunkach wyspowych oraz w przypadku wielkich odbiorników przemysłowych, w szczególności w odbiornikach impulsowych czy w piecach łukowych. Artykuł przedstawia wyniki badań nad zależnością odbitej mocy czynnej od względnej mocy zwarciowej zasilania.
4
Content available remote Reactive Compensation of LTI Loads in Three-Wire Systems at Asymmetrical Voltage
EN
The paper presents fundamentals of design of reactive compensators for total compensation of the reactive and unbalanced currents of linear time invariant (LTI) loads supplied with asymmetrical sinusoidal voltage in three-wire systems. Theoretical fundamentals for the presented method are provided by the Currents’ Physical Components (CPC) based power theory. Development of the reactive compensator equation is the very core of the method presented. A draft of the CPC-based power theory of LTI loads in three-wire systems with asymmetrical, but sinusoidal supply voltage is also presented in the paper.
PL
Artykuł przedstawia podstawy projektowania kompensatorów reaktancyjnych prądu biernego i niezrównoważenia liniowych i czasowo niezmienniczych (LTI) odbiorników trójfazowych zasilanych sinusoidalnym, lecz niesymetrycznym napięciem. Teoretyczne podstawy kompensacji oparte są na Teorii Mocy Składowych Fizycznych Prądów (ang.: Currents’ Physical Components (CPC) – based Power Theory). Głównym elementem przedstawionej metody jest równanie kompensatora reaktancyjnego. Artykuł przedstawia także zarys teorii mocy liniowych czasowo niezmienniczych odbiorników trójfazowych zasilanych niesymetrycznym napięciem sinusoidalnym.
EN
Most of residential and industrial distribution systems as well as traction and distribution systems in commercial buildings are three-phase systems with a neutral conductor, denoted in this paper as 3pN systems. When loads are unbalanced then such systems cannot be now described as a whole in power terms because of a controversy regarding definition of the apparent, even if voltages and currents are sinusoidal. Consequently, it is not clear now how the apparent power and the power factor are affected by the load imbalance. The paper suggests definition of the apparent power for such systems and the power equation. It is based on the supply current decomposition into the Currents’ Physical Components (CPC). The paper introduces two new powers that specify the effect of the load imbalance upon the apparent power of three-phase systems with a neutral conductor at sinusoidal voltages and currents.
PL
Sieci rozdzielcze w dzielnicach mieszkaniowych, zakładach przemysłowych, budynkach handlowych czy publicznych, a także sieci trakcyjne, są budowane zwykle jako sieci trójfazowe z przewodem zerowym. Oznaczane są one w tym artykule jako sieci 3pN. Wtedy, gdy odbiorniki zasilane z sieci 3pN nie są zrównoważone, nie można obecnie napisać równania mocy takich obwodów, trakto-wanych jako całość, a jedynie równania mocy poszczególnych faz. Przyczyną tego jest kontrowersja wokół definicji mocy pozornej w takich obwodach. Przedmiotem niniejszego artykułu jest propozycja definicji mocy pozornej, oraz równanie mocy w obwodach trójfazowych z przewodem zerowym i sinusoidalnymi przebiegami prądu i napięcia. Równanie to wynika z rozkładu prądu zasilania w takich obwodach na Składowe Fizyczne (ang.: CPC).
PL
Niniejszy cykl artykułów poświęcony jest właściwościom energetycznym i kompensacji w obwodach z niesinusoidalnymi przebiegami prądu i napięcia. Jednak w przypadku obwodów trójfazowych rozważania trzeba zacząć od opisu właściwości energetycznych takich obwodów wtedy, gdy przebiegi te są sinusoidalne, gdyż znane równanie mocy, to jest relacja między mocą czynną, bierną i mocą pozorną, jest poprawne tylko wtedy, gdy prądy i napięcia są wzajemnie symetryczne. Gdy wielkości te nie są symetryczne, wówczas równanie to jest błędne, nawet wtedy, gdy prądy i napięcia są sinusoidalne. Jedna z przyczyn tej błędności wynika z rozbieżności w środowisku inżynierów elektryków odnośnie sposobu definiowania mocy pozornej S. W artykule przedstawiono analizę tych definicji i uzasadnienie dla poprawnego wyboru definicji tej mocy oraz wyprowadzono poprawne równanie mocy obwodów trójfazowych, oparte na teorii mocy Składowych Fizycznych Prądu (CPC). Według teorii mocy Składowych Fizycznych Prądu, prąd odbiornika trójfazowego zasilanego symetrycznym i sinusoidalnym napięciem, ma trzy składowe fizyczne: prąd czynny, prąd bierny oraz prąd niezrównoważenia. Właściwości energetyczne takiego obwodu określają nie dwie, lecz trzy moce: moc czynna, bierna i moc niezrównoważenia.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.