Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  Clostridium perfringens
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
PL
Artykuł poświęcony jest oznaczaniu Clostridium perfringens metodą filtracji membranowej zgodnie z PN-EN ISO 14189:2016-10.
2
Content available remote Hygienization of surplus activated sludge by dry ice
EN
The presence of pathogenic microorganisms in sewage sludge is one of the crucial factors affecting their use in agriculture and in nature. An appropriate method of sludge hygienization can contribute to the reduction of the presence of pathogenic microbes in the sludge or to their complete elimination. This study presents the possibility of using dry ice in the hygienization of surplus activated sludge. The scope of survey covered microbiological as well as physiochemical analyses of the sludge. The microbiological analyses conducted show the hygienization effect of dry ice on surplus activated sludge such as the reduction of the total number of bacteria as well as of pathogenic bacteria. In the case of sludge to dry ice 1:1 voluminal ratio, the total number of bacteria has been reduced by 76%, the number of Salmonella sp. rods by 90%, and Clostridium perfringens by 85%. The results of physiochemical analyses confirmed the destructive effect that dry ice has over microorganisms. The disintegration of microbes by means of dry ice contributed to the increase of supernatant liquid turbidity and to the release of organic matter. For the sludge to dry ice 1:1 voluminal ratio, an increase in turbidity of supernatant liquid by 320 mg SiO2 dm-3 has been proven, as well as an increase in the value of CODCr by 549 mg O2 dm-3, which indicates the release of organic matter into the liquid phase.
PL
Obecność mikroorganizmów chorobotwórczych w osadach ściekowych jest jednym z decydujących czynników wpływających na rolnicze i przyrodnicze ich wykorzystanie. Odpowiedni sposób higienizacji osadów może przyczynić się do ograniczenia występowania w nich bakterii patogennych lub całkowitej ich eliminacji. Praca przedstawia możliwość zastosowania suchego lodu do higienizacji osadu nadmiernego. Zakres badań obejmował analizy mikrobiologiczne i fizykochemiczne osadu. Przeprowadzone analizy mikrobiologiczne wykazały higienizujące działanie suchego lodu na osad nadmierny poprzez redukcję ogólnej liczby bakterii i bakterii patogennych. Dla stosunku objętościowego osadu do suchego lodu 1 : 1 ogólna liczba bakterii uległa zmniejszeniu o 76%, redukcja liczby pałeczek Salmonella sp. o 90%, natomiast liczba laseczek Clostridium perfringens obniżyła się o 85%. Potwierdzeniem niszczącego działania suchego lodu na mikroorganizmy były wyniki analiz fizykochemicznych. Dezintegracja drobnoustrojów suchym lodem przyczyniła się do wzrostu mętności cieczy nadosadowej i uwolnienia materii organicznej. Dla stosunku objętościowego osadu do suchego lodu 1 : 1 stwierdzono wzrost mętności cieczy nadosadowej o 320 mg SiO2/dm3 oraz wzrost wartości ChZTCr o 549 mg O2/dm3 wyrażającej uwolnienie materii organicznej do fazy płynnej.
3
Content available Higienizacja osadu nadmiernego suchym lodem
PL
Obecność mikroorganizmów chorobotwórczych w osadach ściekowych jest jednym z decydujących czynników wpływających na rolnicze i przyrodnicze ich wykorzystanie. Odpowiedni sposób higienizacji osadów może przyczynić się do ograniczenia występowania w nich bakterii patogennych lub całkowitej ich eliminacji. Praca przedstawia możliwość zastosowania suchego lodu do higienizacji osadu nadmiernego. Zakres badań obejmował analizy mikrobiologiczne i fizykochemiczne osadu. Przeprowadzone analizy mikrobiologiczne wykazały higienizujące działanie suchego lodu na osad nadmierny poprzez redukcję ogólnej liczby bakterii i bakterii patogennych. Dla stosunku objętościowego osadu do suchego lodu 1 : 1 ogólna liczba bakterii uległa zmniejszeniu o 76%, redukcja liczby pałeczek Salmonella sp. o 90%, natomiast liczba laseczek Clostridium perfringens obniżyła się o 85%. Potwierdzeniem niszczącego działania suchego lodu na mikroorganizmy były wyniki analiz fizykochemicznych. Dezintegracja drobnoustrojów suchym lodem przyczyniła się do wzrostu mętności cieczy nadosadowej i uwolnienia materii organicznej. Dla stosunku objętościowego osadu do suchego lodu 1 : 1 stwierdzono wzrost mętności cieczy nadosadowej o 320 mg SiO2/dm3 oraz wzrost wartości ChZTCr o 549 mg O2/dm3, wyrażającej uwolnienie materii organicznej do fazy płynnej.
EN
The presence of pathogenic microorganisms in sewage sludge is one of the crucial factors affecting their use in agriculture and in nature. An appropriate method of sludge hygienization can contribute to the reduction of the presence of pathogenic microbes in the sludge or to their complete elimination. This study presents the possibility of using dry ice in the hygienization of surplus activated sludge. The scope of survey covered microbiological as well as physiochemical analyses of the sludge. The microbiological analyses conducted show the hygienization effect of dry ice on surplus activated sludge such as the reduction of the total number of bacteria as well as of pathogenic bacteria. In the case of sludge to dry ice 1:1 voluminal ratio, the total number of bacteria has been reduced by 76%, the number of Salmonella sp. rods - by 90%, and Clostridium perfringens - by 85%. The results of physiochemical analyses confirmed the destructive effect that dry ice has over microorganisms. The disintegration of microbes by means of dry ice contributed to the increase of supernatant liquid turbidity and to the release of organic matter. For the sludge to dry ice 1:1 voluminal ratio, an increase in turbidity of supernatant liquid by 320 mg SiO2/dm3 has been proven, as well as an increase in the value of CODCr by 549 mg O2/dm3, which indicates the release of organic matter into the liquid phase.
PL
W ostatnich latach obserwuje się coraz większe zainteresowanie eksploatatorów zakładów wodociągowych możliwością wykorzystania popłuczyn w układach oczyszczania wody przez ich zawrócenie do początku układu oczyszczania, co ma na celu ograniczenie kosztów eksploatacyjnych. Recyrkulacja popłuczyn pozwala obniżyć koszty ujmowania wody (pompowanie, opłaty za korzystanie ze środowiska) oraz koszty odprowadzania tych wód do kanalizacji lub środowiska. W pracy przedstawiono analizę standardowych rozwiązań technologicznych oczyszczania popłuczyn, a także ocenę korzyści i zagrożeń wynikających z ich recyrkulacji. Integralnym elementem pracy jest analiza technologiczna wraz z oceną zagrożeń obecnością bakterii Clostridium perfringens oraz analiza ekonomiczna eksploatacji układu oczyszczania popłuczyn w zakładzie wodociągowym „Goczałkowice”, przeprowadzona w oparciu o dane eksploatacyjne i wyniki badań laboratoryjnych.
EN
In recent years an increasing interest of public water system operators has been observed regarding possible reuse of filter backwash effluent in water treatment systems. This is done by returning backwash waste stream to the head of the treatment system, which is aimed at reducing the operating costs. Filter backwash recycling allows reducing water intake costs (pumping, environment taxes) and costs of water discharge into drains or environment. The paper presents analysis of standard backwash water treatment technological solutions and evaluation of benefits and risks related to filter backwash recycling. Technological analysis including Clostridium perfringens occurrence risk assessment and economic analysis of backwash water treatment operation system at Goczalkowice water treatment plant, carried out based on the operating data and laboratory test results, constitutes an integral part of the paper.
PL
Praca przedstawia możliwość eliminacji Clostridium perfringens w procesie kondycjonowania osadu czynnego nadmiernego z wykorzystaniem promieniowania mikrofalowego. Na podstawie wyników badań stwierdzono, że promieniowanie mikrofalowe (700W i 900W) wykazuje dezintegrujące działanie wyrażone wzrostem wartości ChZT w cieczy nadosadowej: 12 krotny wzrost wartości ChZT przy mocy 700W i 13 krotny przy mocy promieniowania 900W. Fala elektromagnetyczna przyczyniła się do częściowej higienizacji osadu. Spowodowała redukcję liczby Clostridium perfringens odpowiednio o 52% i 56% w czasie 120s oddziaływania, przy mocy 700W i 900W. Redukcja ogólnej liczby bakterii pod wpływem mikrofal wyniosła 42% i 51% (odpowiednio dla 700W i 900W), a pałeczek z rodziny Enterobacteriaceae od 54% do 70% w zależności od mocy promieniowania, czasu działania i własności biochemicznej.
EN
The work presents the possibility of elimination of Clostridium perfringens in surplus activated sludge handling by microwave radiation. An assessment of the impact of microwave radiation as a disintegration and higienisation method of surplus activated sludge was based on an analysis of the value of COD and changes in population of the bacteria Clostridium perfringens and overall sticks in the family Enterobacteriaceae. Basis on the results of the research was concluded that microwave radiation (700W and 900W) shows disintegration action expressed in COD value in the supernatant increase: 12 times increase value of COD with power 700W and 13 times for 900W radiation power. Electromagnetic wave contributed to partial higienisation of surplus activated sludge. The number of Clostridium perfringens decrease about 52% and 56% during the 120s of higienisation process with power 700W and 900W, respectively. Reduction of the overall number of bacteria under the influence of microwave radiation was 42% and 51% (respectively for 700W and 900W), and sticks from the family Enterobacteriaceae from 54% to 70% depending on the power of radiation, the time of operation and biochemical properties
6
Content available remote The influence of Fenton's reagent on the raw sludge disinfection
EN
Fenton's reagent was investigated for its potential for improving the sanitary conditions of the raw mixed sludge (preliminary and surpulus) from wastewater treatment plants. Fenton's reagent doses, i.e., ferrous ions (Fe2+) and hydrogen peroxide (H2O2), as independent agents influencing technological effects were determined. Microbial analysis is concentrated on coliform bacteria, faecal coliform bacteria, anaerobic endosporous Clostridium perfringens and microorganisms from the genus of Salmonella. The most effective method of improving the sanitary conditions of a raw sludge was advanced oxidation process (AOP). The efficiency of the method presented depended directly on chemical reagent doses.
PL
W eksperymencie analizowano możliwość zastosowania odczynnika Fentona do higienizacji mieszanych osadów surowych (wstępnych i nadmiernych). Określono wpływ dawki reagentów chemicznych (jonów Fe2+, H2O2, układu Fe:+/H2O2) na ostateczny efekt technologiczny. Analizy mikrobiologiczne dotyczyły bakterii z grupy coli, bakterii coli typu kałowego, przetrwalnikowych form Clostridium perfringens oraz bakterii z rodzaju Salmonella. Najskuteczniejszą metodą higienizacji analizowanych osadów ściekowych okazała się technika pogłębionego utleniania. Skuteczność prezentowanej technologii rosła wraz z kolejnymi dawkami reagentów chemicznych wprowadzanych do układu.
PL
Porównywano stan sanitarny oraz parametry fizyczno-chemiczne osadów ściekowych w zależności od sposobu ich stabilizacji. Oceniano również możliwość wykorzystania tychże osadów do celów przyrodniczych. Badania prowadzono w dwóch oczyszczalniach ścieków pracujących w systemie "Bardenpho". Próby osadów pobierane były w odstępach trzytygodniowych z czterech punktów pomiarowych. Wykonywano dwa rodzaje badań: mikrobiologiczne oraz fizyczno-chemiczne. W osadach z obu oczyszczalni po procesie stabilizacji nie stwierdzono obecności żywych jaj pasożytów oraz pałeczek z rodzaju Salmonella. We wszystkich próbkach osadu z oczyszczalni I stwierdzono zwiększenie miana bakterii typu coli oraz Clostridium perfringens po stabilizacji, w przypadku oczyszczalni II nie odnotowano zmiany tego wskaźnika w połowie próbek, co może wskazywać na niedostateczną higienizację osadu. W osadach z obu oczyszczalni po procesie stabilizacji stwierdzono spadek liczby bakterii Streptococcus faecalis, zmniejszenie zawartości części organicznych, a wzrost mineralnych. Na podstawie analiz fizyczno-chemicznych stwierdzono w osadach pochodzących z oczyszczalni I podwyższoną zawartość cynku, co dyskwalifikuje wykorzystanie tych osadów do celów rolniczych. Można ich jednak użyć do rekultywacji terenów zdegradowanych, jako że ustabilizowane osady ściekowe posiadają znaczną wartość nawozową.
EN
From the general point of view, the main task of the municipal sewage treatment plant is sewage treatment. The total technological process is optimized regarding the quantity of the contamination removed. The treated sewage and sewage sediments, form the final product of the process. Regarding the quantitative aspect, the final products constitute only 1 ÷ 2% volume of the treated sewage, nevertheless their stabilization increases the costs even by 30%. This issue, arises the necessity of treating the sewage sediments like material, which has to be recycled and used to the greatest possible extent, to ensure at least partial refund. It is estimated, that about 71% of the sediments in Poland is stored. Only 29% is used for the industrial and agricultural purposes, composted or transformed by thermal methods. In EU countries the situation is quite the opposite. The purpose of the paper was to compare the number of organisms, which constitute a sanitary index and physical-chemical parameters of sewage sludge depending on the stabilization method, moreover the paper aims to assess the exploitation possibility of stabilized sediments for the scientific purposes. The research has been conducted in two sewage treatment plants that operate on Bardenpho systems. The samples of the sediments were taken in three week interval's, from five surveying sites. Two types of research were carried out: microbiological and physical-chemical. No eggs of living parasites or Salmonella bacillus were found in the sediments from both treatment plants. In the case of the stabilized sediments' samples collected from the 1st treatment plant, augmenter titers of cola and Clostridium perfringens bacterium were found. The samples taken from the 2nd treatment plant did not reveal any changes, due to the insufficient hygiene of the sediment. In the stabilized sediments from both treatment plants, following changes were observed: a decrease in the quantity of Streptococcus faecalis, reduction of organic matter and an increase of mineral one. On the basis of the physical and chemical analysis increased amount of zinc was observed in the sediments from the 1st treatment plant, what makes the usage of these sludges for agricultural purposes impossible. Nevertheless, it is possible to use them in land reclamation processes, as stabilized sewage sludges have significant fertilizing properties.
PL
Dwutlenek chloru należy do najbardziej trwałych środków dezynfekcyjnych i oprócz skutecznej dezynfekcji znacznie ogranicza dalszy rozwój bakterii w sieci wodociągowej, a jednocześnie ogranicza ilość powstających produktów ubocznych. Dwutlenek chloru jest bardzo dobrym środkiem do mikrobiologicznej kontroli sieci wodociągowych, zwłaszcza tych, które są narażone na skażenie ze względu na specyfikę ujęć wody. Dwutlenek chloru ma ponadto zdolność do zmniejszania warstwy osadów biologicznych w przewodach wodociągowych (biofilm) oraz znacznie lepiej ogranicza w nich obecność żywych bakterii w porównaniu do chloru. W pracy omówiono wykorzystanie dwutlenku chloru do dezynfekcji i kontroli mikrobiologicznej jakości wody do picia, ze szczególnym uwzględnieniem większości występujących w niej zanieczyszczeń bakteryjnych, a zwłaszcza form przetrwalnikujących. Omówiono skuteczne zastosowanie dwutlenku chloru do uzdatniania wody z ujęcia w Szaflarach, zaopatrującego Nowy Targ w wodę do picia, podczas skażenia wód Białego Dunajca bakteriami Clostridium perfringens.
EN
The performance of chlorine dioxide as a biocide was investigated in the water-pipe network of Nowy Targ, which is a municipality of 34 thousands inhabitants in the south of Poland. This disinfectant enables an efficient control of protozoa, bacteria, viruses, algae and resting spores that might be present in the water-pipe network, and in many instances is more efficient then chlorine, UV, chloramines or ozone. The object under study is fed by the riverine water intake (Biały Dunajec) in Szaflary. The application of chlorine dioxide as a disinfectant to the treatment of potable water for the city of Nowy Targ was found to be effective even during episodes of riverine water contamination with the bacterial strain Clostridium perfringens.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.