EN
A simple, environmentally friendly, economical and sensitive method for the determination of trace cadmium has been proposed. The method utilised flow injection on-line solid phase extraction coupled with flame atomic absorption spectrometry (FAAS). Determina- .•-tion was based on the adsorption of cadmium(IT) ions on a mini-column packed with Chelex-100 at pH 7. The influence of eluent composition and concentration, pH of the solution, and flow rates on the preconcentration and elution steps were Investigated. The effects of alkaline, earth alkaline and some transition metal ions on the adsorption of cadmium on Chelex-100 were also examined. The detection limit and recovery for cadmium were 17 ng L-1 and 100-104%, respectively. The proposed procedure was successively applied to the determination of cadmium content in black tea samples and in the following reference materials: stream sediment (GBW07310), sewage sludge (CRM144R), and sea water (CASS-4).
PL
Opracowano prostą, tanią i czulą metodę oznaczania śladowych ilości kadmu stosując przepływowy układ wstrzykowy (Fl) z ekstrakcją on-line 2 fazy stałej i płomieniową atomową spektrometrie absorpcyjną (FAAS). Wykorzystuje ona adsorpcję kadmu przy pH 7 na minikolumnie zawierającej Chelcx-100. Zbadano wpływ składu i stężenia eluentu. pH, szybkości przepływu oraz obecności niektórych jonów metali na wyniki oznaczenia. Granica wykrywalności wynosi 17 ng L-1. Procent odzysku jest zawarty w granicach od 100 do - 104%. Opracowaną procedurę zastosowano do oznaczania zawartości kadmu w próbkach herbaty i certyfikowanych materiałach odniesienia.
EN
A method of speciation determination of Cr(III) and Cr (VI) by selective sorption on Chelex-100 sorbent under pH-controlled conditions has been described. Cr(III) was quantitatively sorbed at pH 6.0 and thus could be determined at ng L-1 level. Only after the preconcentration step, the sorbent was introduced into a graphite furnace as slurry and Cr(III) concentration was determined by ETAAS. Cr(VI) was determined directly in the filtrate, or was calculated as the difference between the total Cr content and the Cr(III) content. The detection limit for slurry was 46 ng kg-1 of Cr(III), and the relative standard deviation was less than 8.5%. The method was applied to the speciation determination of Cr(III) and Cr(VI) in tap and ground waters.
PL
W pracy przedstawiono metodę oznaczania specjacji Cr(III) i Cr(VI) przez selektywną sorpcję na sorbencie chelatującym Che!ex-100, w warunkach kontrolowanego pH. Cr(III) ulegał ilościowej sorpcji przy pH 6.0, co umożliwiło oznaczanie jego na poziomic ng L(-1). Po zagoszczeniu sorbent był wprowadzany bezpośrednio do pieca grafitowego i Cr(VI) oznaczano metodą atomowej spektrometrii absorpcyjnej z atomizacją elektrotermiczną. Cr(VI), który nic ulegał sorpcji na sorbencie, oznaczano bezpośrednio w roztworze otrzymanym po oddzieleniu sorbentu lub obliczano jako różnicę pomiędzy całkowitą zawartością Cr a zawartościąCr(III). Granica wykrywalności przy wprowadzaniu zawiesiny do kuwety grafitowej wynosiła 46 ng kg(-1) dla Cr(III), przy względnym odchyleniu standardowym RSD mniejszym niż 8.5%. Metoda została zastosowana do oznaczania specjacji Cr(III) i Cr(VI) w wodzie do picia i gruntowej.