Content available remote CPC power theory for analysis of arc furnaces
EN
Electric Arc Furnaces (EAFs) are facilities with an intensive use of energy where small improvements in their control imply significant electrical energy savings. The electric arcs are highly nonlinear and chaotic; a power theory for non-sinusoidal voltages and currents is needed for the analysis of the EAFs. The Current´s Physicals Components (CPC) power theory allows an advanced engineering analysis of the energy transfer at arc furnaces since each one of the current components can be used as performance indicators to improve EAFs power control.
PL
Piece łukowe są bardzo nieliniowe i chaotyczne dlatego są bardzo trudne do analizy. Wykorzystanie teorii CPC (Current Physical Components) umożliwia bardziej dokładną analizę przenoszenia energii i poprawę sterowania mocą.
2
Content available remote Accurate CPC power analysis under extreme EAF’s distortion conditions
EN
Electric Arc Furnaces (EAF) are huge energy consumer. However due a limited power calculation the maximum electrical efficiency is not obtained. Most of the applications in market report the usage of inaccurate power quantities in EAF power control system. Because the extreme distortion conditions of power phenomena produced by the nonlinearity of the load in the EAF, the implementation of Current’s Physical Components (CPC) power theory has the potential of describing more appropriate than traditional power theories the physical load conditions and the electric power phenomenon during the Heat Process. Each one of the current components proposed by CPC offer useful information of the load condition, and give indicators which can be useful as stability indicators of the process for a better identification of the EAF stage.
PL
Piece łukowe rzadko osiągają maksymalną skuteczność. Zastosowanie metody Current Physical Component pozwala bardziej dokładnie analizować warunki obciążenia podczas wyładowania i tym samym osiągać mniejsze zniekształcenia i lepszą skuteczność.
PL
Przedmiotem artykułu jest dyskusja nad "jednolitą nową koncepcją mocy biernej prądu niesinusoidalnego w dziedzinie czasu" przedstawioną w przez Prof. Adama Skopca i dr. inż. Czesława Steca w Przeglądzie Elektrotechnicznym, R. 84, Nr. 6/2008. Koncepcja ta dotyczy definiowania mocy biernej Budeanu w dziedzinie czasu. Moc ta została oryginalnie zdefiniowana w dziedzinie częstotliwości. W dyskusji tej zwraca się uwagę na to, że moc ta, a także moc odkształcenia Budeanu, błędnie interpretują zjawiska w obwodzie elektrycznym i po osięmdziesięciu latach od ich wprowadzenia nie mają one ani poznawczej ani technicznej wartości. W dyskusji tej pokazano też, że obecnie tylko dziedzina częstotliwościowa ujawnia wszystkie zjawiska energetycznye w obwodach elektrycznych.
EN
Discussion on "a uniform concept of reactive power of nonsinusoidal currents in a time-domain,' by Prof. Adam Skopec and dr. inż. Czesław Stec, published in Przeglad Elektrotechniczny, R. 84, Nr. 6/2008, is presented. The concept results in Budeanu reactive power definition in time-domain. Originally, it was defined in the frequency-domain. It is pointed out in this discussion that Budeanu reactive and distortion powers misinterpret power phenomena in electrical circuits and, after eighty years since the Budeanu reactive and distortion powers were introduced to electrical engineering, these two powers do not provide either cognitive or practical applications. It was also shown that presently, only the frequency-domain approach makes identification of power phenomena in electrical circuits possible.
EN
The paper shows that the physical interpretation of the instantaneous reactive power q presented by E.H. Watanabe, H. Akagi and M Aredes in the paper "Instantaneous p-q Theory for Compensating Nonsinusoidal Systems", published in Przegląd Elektrotechniczny, R. 84, Nr. 6/2008, is erroneous. Alleged "exchange" energy between phases of supply lines of a three-phase system is not possible. Also it is not possible for energy to rotate around such a line. The paper shows as well that the Instantaneous p-q Theory, in the presence of the supply voltage harmonics or asymmetry, does not provide fundamentals for switching compensator control.
PL
Artykuł pokazuje, że inerpretacja fizyczna chwilowej mocy biernej q, przedstawiona w arykule "Instantaneous p-q Theory for Compensating Nonsinusoidal Systems", opublikowanym przez E.H. Watanabe, H. Akagi oraz M Aredes'a w Przeglądzie Elektrotechnicznym, R. 84, Nr. 6/2008, jest błędna. Domniemana w tym artykule "wymiana energii" między fazami układu trójfazowego nie jest możliwa, podobnie jak nie jest możliwe wirowanie energii wokól linii zasilającej. Artykuł ten pokazuje także, że Instantaneous p-q Theory nie tworzy popranych podstaw kompensacji przy niesinusoidalnym napięciu zasilania odbiorników trójfazowych.
EN
This paper presents the comparison among the control algorithms of a three phase, three wire shunt active power filter. The control algorithms are based on: 1) the current's physical components theory, 2) the p-q power theory. The active power filter operation under the distorted supply voltage at the point of common coupling condition is considered. The comparison concerns the aspects of: filtering current harmonics, reactive power compensation (defined in the fundamental harmonic domain), supply current balancing and dynamic performance. The results of the laboratory investigation, using the fast prototyping system dSPACE, are given in the paper. This paper confirms that the current's physical components theory allows developing the control algorithm of shunt active power filter and its practical implementation. The investigation allows the conclusion that this control algorithm enables achieving the supply system current shape close to the sinusoidal, despite shunt active power filter operation under the distorted supply voltage. A sinusoidal supply current cannot be attained by the control algorithm based on the p-q power theory without some additional control elements, such as: PLL, signal filters, etc. The experiment also has shown that the control algorithm based on the p-q power theory is easier to implement and less demanding in terms of hardware than the control algorithm based on the current's physical components theory.