Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  AlphaGUARD
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Owing to the high potential of radon to increase the risk of lung cancer, health organizations are enforced to update their regulations and recommendations regarding indoor radon levels each year. In this study, the indoor radon concentrations of three randomly selected thermal baths in Hungary using CR-39 and an AlphaGUARD radon monitor were measured with regard to the new updated standards of the European Basic Safety Standard (EU BSS, Council Directive 2013/59/Euratom, 2014). The annual average of indoor radon concentrations in Parad Medical Bath, Igal Health Spa and Eger Turkish Bath were measured as 159 ± 19, 176 ± 27 and 301 ± 30 Bq/m3, respectively. Indoor radon concentration in all measurement locations were determined to be below the reference level, with the exception of the main pool, small pool and sparkling bath areas in the Eger Turkish Bath that were measured as 403 ± 42, 315 ± 32 and 354 ± 36 Bq/m3, respectively. In light of the results, the estimated annual average radon concentration in the thermal baths was below the EU BSS reference level of 300 Bq/m3. Personal dosimetry is required to estimate the annual effective dose from inhaled radon by the workers at the Eger Turkish Bath. This procedure is required in order to justify the application of the mitigation process of decreasing working hours, improving the ventilation rate or increasing the number of classified employees in response to the official radiation surveillance programme.
2
Content available Issues of radon (Rn-222) exhalation measurements
EN
The Rn-222 isotope, a naturally occurring radioactive gas, is created in a radioactive decay of Ra-226. Both radionuclides belong to the radium decay chain in which U-238 is the prime parent. Radon is usually in plenty found in the earth crust, rocks, soil, water and air, therefore it is regarded as an indicator of ionizing radiation dose received by a population. Due to radon negative influence on people’s health, measurements of its concentration are commonly performed. The presented research concerns assessment of measurements uncertainty of Rn-222 concentration exhaled from soil. The measurements were repeated at the same site. The experiment was carried out in natural conditions, in the city center and lasted about half a year. In Rn-222 concentration measurements the AlphaGUARD radon monitor was used. The device was operating in the 10-minutes flow mode, with the air pump and exhalation-box arranged in the closed cycle. The studies have shown a significant differences between results of radon exhalation measurements, which were carried out sequentially in the same place. Generally, increase in measurements number in a series lowers the result uncertainty. Consequently, the number of measurements in a series can be adjusted to the desired uncertainty of result. What is more, the distribution of the results in series is well described by the Poisson distribution.
PL
Izotop Rn-222, naturalnie występujący radioaktywny gaz, powstaje na skutek rozpadu promieniotwórczego Ra-226. Oba radionuklidy należą do szeregu uranowo-radowego, który rozpoczyna U-238. Radon występuje w dużych ilościach w skorupie ziemskiej, skałach, glebie, wodzie i powietrzu, dlatego jest on traktowany jako wskaźnik dawki promieniowania jonizującego otrzymywanego przez ludzi. Ze względu na negatywny wpływ radonu na zdrowie ludzi pomiary stężenia tego gazu są często wykonywane. Zaprezentowano wyniki badań niepewności pomiarowej stężenia Rn-222 w powietrzu ekshalowanym z gleby. Pomiary powtarzano wielokrotnie w tym samym miejscu. Eksperyment przeprowadzony został w warunkach naturalnych, w centrum miasta i obejmował okres około pół roku. Do pomiarów stężenia radonu wykorzystano monitor radonowy AlphaGUARD. Pracował on w 10-minutowym trybie przepływowym, z pompą oraz komorą ekshalacyjną w obiegu zamkniętym. Badania wykazały znaczne różnice pomiędzy wynikami pomiarów, wykonywanych w całym okresie badawczym. W pojedynczej serii większa liczba pomiarów zmniejsza niepewność pomiarową. Dzięki temu ilość pomiarów w serii może być dostosowana do oczekiwanej niepewności pomiarowej wyniku. Stwierdzono, że rozkład wyników aktywności radonu w serii jest dobrze opisywany przez rozkład Poissona.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.