Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  AC voltage
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Solar-blind ultraviolet cameras with image intensifier with CMOS detector typically use various count methodologies to measure the optical energy of an electrical corona. However, these count methodologies are non-radiometric without considering parameters such as distance, focus-, zoom-, and gain setting of a camera. An algorithm which considers the calibration and radiometric measurement of optical energy for the slow frame rate intensifier type cameras is presented. Furthermore, it is shown how these calibration data together with the flowcharts are used for the conversion from raw measured data to radiometric energy values.
EN
Solar-blind ultraviolet cameras as part of high-voltage electrical inspections until recently have mostly been used for pure observations. These observations only imply the presence of corona discharges and not the severity thereof. A radiometric algorithm together with a calibration algorithm to perform an optical energy measurement were presented earlier. This is a guide on how to apply the algorithm to determine the total optical measurement from corona discharges, plus additional processing. This guide and additions are used to compare the electrical and optical domains with actual examples. The main objective is to illustrate how to determine the electrical and optical relation for the IEC 60720 high-voltage electrical test configurations using a standard open procedure.
PL
W referacie zaprezentowano metodę do pomiaru wartości kąta przesunięcia fazowego pomiędzy sygnałami prądu i napięcia przemiennego z odniesieniem wyniku pomiaru do państwowego wzorca jednostki miary kąta płaskiego, z wykorzystaniem enkodera inkrementalnego. Opracowana metoda pomiarowa ma zastosowanie do pomiaru wartości kątów przesunięć fazowych pomiędzy sygnałami o znacznej amplitudzie i znacznej różnicy wartości tych amplitud. Spójność pomiarowa pomiaru kątów między sygnałami elektrycznymi jest najczęściej odnoszona do Państwowego wzorca jednostek miar czasu i częstotliwości. W przypadku pomiarów kąta między sygnałami prądu i napięcia w elektroenergetyce zapewnienie spójności pomiarowej do wzorca czasu i częstotliwości jest bardzo kłopotliwe ze względu na duże wartości amplitud mierzonych sygnałów oraz na występujące duże różnice wartości amplitud.
EN
The paper presents a method for measuring the value of the phase angle between current and alternating current signals with reference to the national standard of the angle of flat unit, using an incremental encoder. The developed measurement method is used to measure the values of the phase shift angles between high amplitude signals and a significant difference in the values of these amplitudes. The traceability for the measurement phase of angle between electrical signals is most often referred to the national time and frequency standard. In the case of measuring angles between current and voltage signals in the power supply, it is very troublesome to ensure the consistency of the measurement with the time and frequency standard because of the large amplitude values of the measured signals and differences amplitude.
EN
The partial discharge diagnosis is an established instrument for the condition assessment of high voltage insulations and equipment. Under AC voltage stress the phase resolved pattern is of great significance in order to become aware of the type of fault. As a result of the inapplicability for DC voltage stress, approaches for alternative interpretation techniques such as the time domain analysis of partial discharges were identified in recent investigations. In these different types of fault are taken into account as well as different insulating media. The purpose of this paper is to investigate whether an analysis of the pulse shape is also applicable for the defect identification under AC voltage stress. By focussing on gaseous insulating media, contact noise and surface discharges are emulated in ambient air, whereas corona discharges are emulated in ambient air and oxygen. A method for analysing discharges, occurring in the negative and the positive half-wave of the test voltage, is proposed and discussed.
PL
W artykule przedstawiono rolę, jaką spełniają termiczne przetworniki wartości skutecznej (TVC) dla zapewnienia spójności pomiarowej w zakresie napięć AC niskich częstotliwości (do 1 MHz) w Głównym Urzędzie Miar (GUM). Przedstawiono metodę pomiarową komparacji dwukanałowej stosowaną w GUM do wzorcowania termicznych przetworników AC/DC wartości skutecznej napięcia elektrycznego przemiennego (AC). W drugiej części opisano procedurę szacowania niepewności dla tej metody i przedstawiono przykładowy budżet niepewności. Przedstawiono także przykładowe wyniki porównania wzorcowań przetwornika termicznego przeprowadzonych w GUM i w PTB (Niemcy) potwierdzające poprawność stosowanej metody komparacji.
EN
The paper discusses thermal voltage converters (TVC) as reference standards for low AC voltages. The Central Office of Measures (GUM) in Warsaw, Poland, like many other NMIs, uses TVCs as reference standards for AC voltages. More precisely, a set of single-junction Holt Model 11 TVCs is used as a reference standard for AC voltages above 600 mV, while a semiconductor multi-range Fluke 792A TVC serves as a highest level working standard for these voltages and as a reference standard for the AC voltages below 600 mV. The precise traceability chart for AC voltages is shown in Fig. 2. The AC voltage unit is transferred at GUM using the dual - channel method for TVC comparison. This method is discussed and schematic of the measurement system is shown in Fig. 5. The consecutive equation describing an AC-DC difference of the TVC is discussed (equations (3) and (4)). The full analysis of the uncertainty budget is performed following the JCGM guide recommendations. Finally, two practical examples of the experimental results are given. In the first example a Fluke 792A TVC calibration at 10 V AC and 1 kHz is analysed and the measurement uncertainty is calculated (Tab. 1). In the second example the calibration results obtained at GUM and at PTB are compared for the same Fluke 792A TVC at 600 mV and frequencies ranging from 10 Hz to 1 MHz (Fig. 6).
6
Content available remote Dwubiegowy silnik synchroniczny synchronizowany napięciem zmiennym
PL
W pracy wykazano możliwości uzyskania efektu łagodnej synchronizacji przez zasilanie uzwojenia wzbudzenia silnika synchronicznego, w stanie pracy asynchronicznej, napięciem przemiennym z wykorzystaniem jednofazowego falownika napięcia. Przyjęta metoda synchronizacji została porównana z innymi proponowanymi metodami synchronizacji. Analizę procesów synchronizacji wykonano stosując opracowany polowo-obwodowy model dwubiegowego silnika synchronicznego dużej mocy typu GAe 1716/20t, pracującego w napędach wentylatorów głównych kopalni podziemnych. Wyniki obliczeń zamieszczono w postaci wykresów czasowych.
EN
The work presents calculation results of synchronization process of two-speed, silent-pole, high power synchronous motor type GAe 1716/20t. The calculations were based on examined and validated by measurements, field-circuit calculation model of the motor. The two-speed motor runs in the drive of a WPK 5.3 mine fan in deep mines. The influence of voltage inverter in excitation circuit on gentle synchronization process was studied. The influence of AC or DC field voltage on stator currents, field current, electromagnetic torque and rotational speed during synchronization process was compared. The calculation results are presented as diagrams over time.
PL
W pracy przedstawiono analizę właściwości widmowych sygnału wytwarzanego przez cyfrowe źródło wzorcowego napięcia przemiennego, wyposażone w przetwornik cyfrowo-analogowy (c/a) wykorzystujący zasadę modulacji szerokości impulsu (PWM). Dokonano analizy widmowej sygnału przy założeniu nieograniczonej rozdzielczości nastawy współczynnika wypełnienia oraz w przypadku gdy ta rozdzielczość jest ograniczona do 9 lub 16 bitów.
EN
The paper contains the analysis of the spectral properties of the signal generated by the source of the standard ac voltage, equipped with a pulse-width-modulated digital to analog converter. The spectrum of the PWM modulator was calculated for the PWM modulator with infinitely high resolution of the duty cycle adjustment and for the modulator with 9 or 16 bit resolution of the duty cycle setting.
PL
Pomiary napięcia przemiennego w Głównym Urzędzie Miar są odnoszone do wzorców odtwarzanych przy napięciu stałym, wg zasady komparacji niejednoczesnej. W charakterze wzorca odniesienia przy napięciu przemiennym stosowane są zestawy przetworników termoelektrycznych. Struktura wzorca, dzięki różnym konfiguracjom, umożliwia pokrycie potrzeb wzorcowania tej wielkości do 1200 V i częstotliwości do 1 MHz. Omówiono istotę i źródła błędu komparacji, oraz sposób jego kompensacji. Schemat interkomparacji wzorca umożliwia odniesienie całej dziedziny do jednego przetwornika bazowego 1 VAC.
EN
AC voltage measurements at the Central Office of Measures are being referenced to the standards restored at the DC voltage according to the principle of anti-coincidental comparison. As an AC voltage reference standard sets of thermoelectric converters are being used. Thanks to different configurations,the structure of the standard,enables covering the calibration needs of this quantity up to 1200 V at the frequency of up to 1 MHz. The nature and sources of comparison error were discussed as well as the way of its compensation. The schematic diagram of intercomparison enables referencing the whole field to one 1 VAC base converter.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.