Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  ścieki szpitalne
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Purpose: This investigation aims to study the various approaches currently used to reduce the load on computer servers in order to better manage data on hospital wastewater treatment and solid waste generation. Design/methodology/approach: This manuscript investigates the taxonomies of deduplication procedures based on literature and other data sources, thereby presenting its classification and its challenges in detection. Findings: Based on the literature survey of deduplication techniques, the method of deduplication dispensed on cloud gadget devices has been found to be a promising research challenge. The gaps discussed include a reduction in storage space, bandwidth, type of disks used, and expenditure on energy usage and heat emissions when implementing these strategies. The art work on a scalable, robust, green and allocated approach to deduplication for a cloud gadget will remain of interest in destiny. Research limitations/implications: Considerable attention is focused on the deduplication due to efficient, extensive storage system. Practical implications: This research paper will be useful to identify deduplication techniques which are nowadays used in different hospital wastewater data collection systems and put significant proposals for further improvements in deduplication. Originality/value: This manuscript portrays a broader assessment of the available literature for data duplication along with the classification of different methods for the data storage used in the different level of storage of hospital wastewater data collection.
PL
W celu określenia potencjału toksykologicznego, a tym samym prognozowania skutków jakie może wywołać depozycja nieoczyszczonych lub też niedostatecznie oczyszczonych ścieków szpitalnych względem biocenoz zasiedlających akweny wodne stanowiące odbiorniki ścieków po procesie oczyszczania, przeprowadzono analizę ekotoksykologiczną. Badania przeprowadzono na rzeczywistych próbkach ścieków szpitalnych. Zakres analizy ekotoksykologicznej obejmował przeprowadzenie następujących testów: testy immobilizacji skorupiaków Daphnia magna, test przeżywalności skorupiaków z gatunku Thamnocephalus platyourus oraz Artemia salina, a także test inhibicji wzrostu kolonii orzęsków Tetrahymena termophila. W ramach każdego testu, w oparciu o wyniki cząstkowe wyznaczono wartości wskaźników ekotoksykologicznych EC 50 (ang. effect concentration), które następnie przekształcono na jednostki toksyczności TU (ang. Toxic Unit) na podstawie których dokonano klasyfikacji toksyczności analizowanych próbek ścieków. W ramach przeprowadzonych badań, próbki ścieków szpitalnych sklasyfikowane zostały jako medium charakteryzującego się ostrą toksycznością. Z przeprowadzonych badań wynika, że ścieki szpitalne stanowią poważne zagrożenie względem organizmów zasiedlających ekosystemy wodne, a ich niedostateczne oczyszczenie lub też niekontrolowany zrzut do środowiska może wywołać katastrofalne skutki względem organizmów zasiedlających narażoną biocenozę.
EN
In order to assess the toxicological potential and thus forecast the potential effect posed by untreated hospital wastewater discharges according to exposed ecosystem, the ecotoxicological analysis were performed. During the study the real samples of hospital wastewater were used. The ecotoxicological analysis included the following tests: immobilization test according to crustacean Daphnia magna; mortality test according to crustacean Thamnocephalus platyourus and Artemia salina and growth inhibition test relative to ciliates Tetrahymena termophila. Within each test, the value of ecotoxicological indicators EC50 (effect concentration) were estimated. The EC50 value were transformed into the Toxic Unit (TU), basis of which the analyzed hospital wastewater samples were classified. The results proves that hospital wastewater pose a serious threat to exposed aquatic organisms and their insufficient purification as well as uncontrolled discharge into the environment may cause adverse changes in the environment.
4
Content available remote Środki cieniujące w ściekach i środowisku wodnym
PL
Przedstawiono i scharakteryzowano najczęściej stosowane środki cieniujące. Substancje te z założenia powinny być niegroźne dla zdrowia człowieka, lecz mogą one stanowić zagrożenie dla organizmów wodnych. Dokonano przeglądu literatury dotyczącej występowania tych związków w ściekach oraz środowisku naturalnym. Efektywne oczyszczenie ścieków szpitalnych i komunalnych jest niezbędne w ochronie wód powierzchniowych i podziemnych przed zanieczyszczeniami organicznymi, w szczególności farmaceutykami. Jednakże, jak wynika z danych literaturowych, środki kontrastujące nie są usuwane w procesach oczyszczania ścieków w stopniu wystarczającym i dochodzi do ich emisji do środowiska wodnego.
EN
A review, with 26 refs., of contrast agents and their occurrence in aquatic environment.
EN
Iodinated contrast media compounds (ICM) have been identified in wastewater within the last 20 years. In this study, the biodiversity of activated sludge in anaerobic membrane bioreactors dealing with synthetic hospital wastewater with addition of ICM was investigated, using fluorescent in situ hybridization (FISH) and denaturing gradient gel electrophoresis (DGGE). During the adaptation of microorganisms to anaerobic growth conditions and to ICM presence, differences in the content of Alpha- and Betaproteobacteria were noted and bioreactors showed higher biological diversity (H = 2.9), suggesting that ICM were not toxic to the bacteria. The long sludge age had the strongest influence on the composition of activated sludge biocenosis.
EN
PCR-RAPD (Polymerase Chain Reaction – Random Amplified Polymorphic DNA) is a PCR based method used for biodiversity, phylogenetics, genotoxicity and cancerogenesis research. It possesses several advantages, such as no necessity for information about DNA sequence or multiple primers usage for generating a great deal of fingerprints data. But on the other hand PCR-RAPD is known to be unrepeatable and generating unspecific PCR products, if PCR is not optimized for a particular biological material. The aim of this experiment was to optimize PCR-RAPD with a modified Taguchi method for its usage for genotoxicity analysis. The research was performed on DNA isolated from onion (Allium cepa) root meristem cells. The plants were grown on medium containing an increasing concentration of hospital wastewater in order to observe its genotoxic influence on eukaryotic DNA. The wastewater derived from Hospital for Phthisiatry and Lung Diseases in Pilchowice, Poland, where large amount of anti-tuberculosis and anti-cancer drugs are used. The research proved modified Taguchi method being useful for optimal PCR mixture. In the experiment repeatable RAPD results with no additional nonspecific PCR products were received. It was also stated that PCR-RAPD is useful for genotoxicity analysis performed with plant DNA.
PL
PCR-RAPD (Polymerase Chain Reaction – Random Amplified Polymorphic DNA) jest odmianą PCR wykorzystywaną w badaniach bioróżnorodności, filogenezy, genotoksyczności oraz kancerogenezy. Do jej zalet zalicza się brak konieczności znajomości badanej sekwencji DNA oraz możliwość użycia wielu rodzajów starterów reakcji. Z drugiej strony jednak wyniki uzyskiwane tą metodą są uznawane za niepowtarzalne, a w reakcji PCR generowane są często niespecyficzne produkty, jeśli metoda nie jest zoptymalizowana do badanego materiału. Celem tego eksperymentu była optymalizacja techniki PCR-RAPD za pomocą zmodyfikowanej metody Taguchi, wykorzystanej do badań nad genotoksycznością ścieków szpitalnych. Badania prowadzono na DNA izolowanym z komórek merystemów korzenia cebuli (Allium cepa), hodowanych na pożywce zawierającej rosnące stężenia ścieków szpitalnych, pochodzących ze Szpitala Chorób Płuc w Pilchowicach, uznawanych za potencjalnie genotoksyczne w stosunku do komórek eukariotycznych, ze względu na wysoką zawartość pozostałości leków przeciwgruźlicznych i antynowotworowych. Przeprowadzone analizy udowodniły użyteczność zmodyfikowanej metody Taguchi do optymalizacji składu mieszaniny reakcyjnej do techniki PCR-RAPD. Uzyskane wyniki były powtarzalne, a w trakcie reakcji nie generowano niespecyficznych produktów PCR. Stwierdzono również użyteczność metody PCR-RAPD do analiz genotoksyczności z użyciem roślinnego DNA.
7
Content available remote Toxicity assessment of hospital wastewater by the use of a biotest battery
EN
In the paper toxicity assessment of hospital wastewaters samples was performed using direct-contact tests consisting of five species, which represent three different trophic levels of the food chain. IC_50 or EC_50 values were estimated for each tested organism: Pseudokirchneriella subcapitata IC_50/72h 18.77%, Daphnia magna EC_50/48h 20.76%, Thamnocephalus platyurus EC_50/24h 22.62%, Artemia salina EC_50/24h 59.87% and Vibrio fisheri EC_50/15min 46.17%. Toxic potential of hospital wastewater was described using a system of wastewater toxicity classification. The toxic units (TU) values estimated for each test indicate that hospital wastewaters are toxic (Class III). The variable results of the tests' sensitivity confirmed the need of application of microbiotests battery with organisms of different trophic levels.
PL
Do oceny potencjału toksykologicznego ścieków szpitalnych zastosowano baterię biotestów z wykorzystaniem pięciu gatunków reprezentujących trzy różne poziomy troficzne. Wartości wskaźników ekotoksykologicznych wyznaczone w poszczególnych testach wyniosły: test inhibicji wzrostu glonów Pseudokirchneriella subcapitata IC_50/72h 18,77%, testy toksyczności ostrej z wykorzystaniem skorupiaków Daphnia magna EC_50/48h 20,76%, Thamnocephalus platyurus EC_50/24h 22,62%, Artemia salina EC_50/24h 59,87% oraz test toksyczności chronicznej z wykorzystaniem bakterii morskich Vibrio fischeri EC_50/15min 46,17%. Dla każdego testu obliczono jednostki toksyczności TU, na podstawie których analizowane próby ścieków szpitalnych zaklasyfikowano jako toksyczne. Szeroki zakres otrzymanych wartości wskaźników ekotoksykologicznych wyznaczonych dla poszczególnych organizmów testowych, potwierdza konieczność stosowania rozbudowanej pod względem różnorodności organizmów baterii biotestów.
8
Content available remote Nierozwiązany problem ścieków szpitalnych
PL
Przedstawiono przegląd składu ścieków szpitalnych, a następnie porównano go ze składem ścieków komunalnych. Omówiono stan prawny dotyczący odprowadzania ścieków szpitalnianych, po oczyszczeniu, bezpośrednio do odbiornika, a następnie do sanitarnej kanalizacji miejskiej. Niedostatki przepisów prawnych zostaty ukazane i uwypuklone.
EN
Hospital wastewater physical, chemical and bacteriological parameters have been briefly described and compared with composition of typical municipal sewage. The legal status of hospital wastewaters disposal have been discussed in the case of discharging them first directly to rivers (after treatment) and then to municipal sewerage systems. Some shortcomings of Polish law requirements have been pointed out.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.