Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 27

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  ściana usztywniająca
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
The seismic performances of 28 geometrically similar concrete shear walls reinforced with basalt fiber-reinforced polymer (BFRP) bars were simulated using a mesoscale modeling approach. In the modeling, concrete heterogeneities were explicitly described, and the interaction between BFRP bars and surrounding concretes was also considered. The influences of shear depth, shear span ratio and vertical reinforcement ratio on the failure of shear walls were investigated. The simulation results indicated that with the increase of shear depth, the failure modes were basically the similar, while the nominal shear strength decreased significantly, namely, the presence of size effect was demonstrated. The shear wall would exhibit different failure modes as the shear span ratio varies. Moreover, it was found that the vertical BFRP bar presented an ignorable influence on the failure mode, while the increase of vertical reinforcement ratio would obviously improve the shear strength of BFRP-RC shear wall. Finally, the present simulated shear strengths were compared with some available size effect laws and some codes.
EN
The internal forces in stiffening walls are usually determining by numerical methods. Extreme values of forces and displacements can be achieved without significant problems. The numerical model is always labour-intensive; therefore, it is not used for single-family or multi-family buildings with a simple wall layout. To calculate efficiently internal forces in such walls uses an analytical model. Eurocode 6 (prEN 1996-1-1:2019) does not provide specific guidelines for determining geometrical characteristics and procedures for calculating the values of internal forces in the stiffening walls. The use of numerical methods and other reliable methods was allowed. The paper presents the adaptation of the total stiffness method to determine internal forces in a building with a simple wall system. The method was based on dividing the masonry wall with openings into pillars, lintels, bottom sprandels and flanged walls. The analytical results were compared with linear-elastic FEM calculations. It has been demonstrated that flexural stiffness, shear stiffness and localization of rotation centre (RC) had a crucial impact on masonry structure.
PL
Zasadniczym celem pracy była adaptacja metody całkowitej sztywności ścian do rozdziału obciążeń na ściany usztywniające w budynku o prostym układzie ścianowym według ogólnych zaleceń Eurokodu 6. Na wstępie przedstawiono normowe zalecenia dotyczące ścian usztywniających podane w Eurokodzie 6. Następnie zaproponowano uszczegółowienie procedury obliczeniowej. Przyjętą procedurę porównano z wynikami obliczen MES modelu budynku o prostym układzie ścianowym. Wiekszość zaleceń normowych nie podaje szczegółowych wytycznych i procedur rozdziału sił oraz wyznaczania sił wewnętrznych w murowanych ścianach usztywniających. Przepisy ograniczają się do ogólnych zaleceń dotyczących identyfikacji ścian usztywniających, ewentualnej współpracy z innymi elementami budynku oraz do opisu warunków konstrukcyjnych. Dotyczy to również projektu Eurokodu, 6 w którym jednak do stosowania dopuszczono wiarygodne metody analityczne lub metody numeryczne bazujące na MES. W pracy dokonano adaptacji przepisów kanadyjskich (National Building Code of Canada (NBCC) 2005) do opracowania metody obliczania całkowitej sztywności ściany. Uwzględniając zapisy Eurokodu 6 (w aspekcie współpracy z innymi ścianami) wyznaczono zależności pozwalające na wyznaczenie przemieszczeń ściany z otworami, dzięki podziałowi na elementy składowe. Przemieszczenia składowych elementów ściany wyznaczono w zależności od geometrii i warunków brzegowych ściany. Przy obliczeniach całkowitej sztywności ściany uwzględniono odkształcenia giętne oraz postaciowe.
PL
W artykule przedstawiono wyniki badania ścian niezbrojonych i zbrojonych, z otworami różnych kształtów, wykonanych z silikatowych elementów murowych. Podstawowym celem przeprowadzonych eksperymentów było określenie wpływu zastosowanego zbrojenia na morfologię zarysowań oraz mechanizm zniszczenia. Wszystkie ściany wykonano z silikatowych elementów murowych z pionowymi drążeniami (grupa I wg PN-EN 1996-1-1:2013). Zbadano 12 ścian o zewnętrznych wymiarach l = 4,45 m, h = 2,45 m, t = 180 mm z otworami zróżnicowanymi pod względem kształtu i wymiarów. Do zbrojenia zastosowano stalowe kratowniczki typu EFZ 140/Z 140 type (typ Z1) oraz siatki z tworzywa sztucznego (typ Z2). Wykazano, że rozwój zarysowań zależał od wielkości otworu. W ścianach zbrojonych propagacja zarysowań była istotnie ograniczana.
EN
The article presents the results of tests of unreinforced and reinforced walls with openings of various shapes made of calcium silicate masonry units. The main aim of the conducted experiments was to determine the influence of the applied reinforcement on the cracking morphology and the failure mechanism. All walls are made of calcium silicate masonry elements with vertical traverses (group I according to PN-EN 1996-1-1:2013). 12 walls with external dimensions of l = 4,45 m, h = 2,45 m, t = 180 mm with openings of different shape and dimensions were constructed and tested. Steel trusses of the EFZ 140/Z 140 type (type Z1) and plastic meshes (type Z2) were used for reinforcement. It was shown that the development of cracking depended on the size of the opening. In reinforced walls, the propagation of scratches was significantly limited.
4
Content available remote Design and performance parameters of shear walls: a review
EN
Reinforced concrete (RC) walls are used in buildings to provide lateral stiffness and strength against lateral forces like earthquake, wind etc. Shear walls are one of the most important lateral load-resisting systems in high-rise buildings. This paper provides an overview of not only reinforced concrete (RC), but also composite shear walls. The paper focuses on four inter-related review areas, namely i) conventional shear walls with rectangular cross section, ii) coupled shear walls, iii) composite shear walls, and iv) shear walls with opening(s). Behavior of shear walls which are the most damaged structural elements during earthquake and the parameters affecting this behavior are evaluated in this paper. However, this paper presents the available information about the design and performance parameters of shear walls.
5
Content available remote Zarysowanie i zniszczenie ścian skrępowanych ścinanych poziomo
PL
W artykule przedstawiono wyniki naprężeń rysujących i niszczących sześciu ścian skrępowanych ścinanych poziomo wykonanych z elementów murowych z ABK. Wymiary zewnętrzne ścian wynosiły: grubość t = 0,18 m; długość l = 4,43 m; wysokość h = 2,49 m. Ściany badano przy wstępnych naprężeniach ściskających σc = 0,1; 0,75 i 1,0 N/mm2. Analizowano wartości naprężeń rysujących i niszczących w odniesieniu do wyników badań ścian niezbrojonych, zbrojonych stalowymi kratowniczkami i siatkami z tworzywa sztucznego.
EN
The paper presents the results of cracking and ultimate shear stresses of 6 confined walls made of AAC masonry units. The external dimensions of the walls were: thickness t = 0.18 m; length l = 4.43 m; height h = 2.49 m. The walls were tested at initial compressive stresses equal to σc = 0.1; 0.75 and 1.0 N/mm2. The values of cracking and ultimate shear stresses were analyzed in relation to the results of tests of unreinforced walls, walls reinforced with steel trusses and plastic grid.
6
Content available remote Morfologia zarysowań ścian skrępowanych ścinanych poziomo
PL
W artykule przedstawiono wyniki badań ścian skrępowanych (6 modeli) wykonanych z elementów murowych z autoklawizowanego betonu komórkowego (ABK). Wymiary zewnętrzne ścian wynosiły: grubość t = 0,18 m, długość l = 4,43 m, wysokość h = 2,49 m. Ściany badano przy wstępnych naprężeniach ściskających σc = 0,1; 0,75 i 1,0 N/mm2. Skrępowanie wykonano w postaci dwóch zewnętrznych pionowych rdzeni i dwóch poziomych rygli, które zazbrojono zgodnie z wymaganiami PN-EN-1996-1-1. Analizowano morfologię zarysowań ścian i mechanizm zniszczenia elementów.
EN
The paper presents the results of confined (6 walls) made of masonry elements with AAC. Overall dimensions were: thickness t = 0.18 m, length l = 4.43 m and the height of h = 2.43 m. The walls were tested at initial compressive stresses perpendicular to the plane of the bed joints σc = 0,1; 0,75; and 1,0 N/mm2. In the confined models two external vertical cores and two horizontal beams were made, which were reinforced in accordance with the requirements of PN-EN-1996-1-1. The morphology of cracking and the mechanism of destruction were analyzed.
PL
W artykule zaprezentowano wyniki badań dziesięciu ścian (1× h × t = 4,43 × 2,43 × 0,18 m), wykonanych z elementów murowych z ABK, poddanych obciążeniom ścinającym. W ścianach wykonano trzy typy otworów (A, B i C), zróżnicowanych pod względem kształtu i wymiarów. Elementy badano przy zróżnicowanych wstępnych naprężeniach ściskających. Analizowano wpływ wstępnych naprężeń ściskających na odkształcenia postaciowe w chwili zarysowania oraz deformacje postaciowe uzyskane przy największych naprężeniach ścinających. Przedstawiono określoną empirycznie sztywność ścinania ścian z otworami także w funkcji wstępnych naprężeń ściskających.
EN
The article presents of own results of the 10th walls (1 × h × t = 4.43 × 2.43 × 0.18 m) subjected to shear loads made of AAC masonry units. Three types of openings (A, B and C) were formed in the walls, different in terms of shape and dimensions. The elements were tested at different initial compressive stresses. The results of the research were analyzed in terms of the influence of initial compressive stresses on the non-dilatational strain angle at the time of cracking and the deformations angle obtained at the highest shear stress. Empirical shear stiffness of the wall with openings is also presented as a function of initial compressive stresses.
PL
Oprócz mechanizmu zarysowania i zniszczenia ścian usztywniających z otworami praktyczne znaczenie mają także wartości naprężeń rysujących i niszczących. Przeanalizowano wyniki badań własnych dziesięciu ścian o długości 1 = 4,43 m, wysokości h = 2,43 m oraz grubości t = 180 mm. Ściany z trzema typami otworów (A, B i C) badano przy zróżnicowanych wstępnych naprężeniach ściskających. Otrzymane wyniki badań ścian analizowano pod względem zależności naprężenie – odkształcenie oraz wpływu wstępnych naprężeń ściskających.
EN
Apart from the mechanism of cracking and destruction of shear walls with openings the values of cracking and ultimate stresses have practical significance. The results of own tests of 10 walls with length 1 = 4.43 m, height h = 2.43 m and thickness t = 180 mm are analyzed. Walls with three types of holes (A, B and C) were tested at different initial compressive stresses. The obtained wall test results were analyzed in terms of stress and strain relations obtained and the effect of initial compressive stresses.
9
Content available remote Badania ścian usztywniających z otworami, wykonanych z ABK
PL
W artykule zaprezentowano wyniki badań dziesięciu ścian wykonanych z elementów murowych z autoklawizowanego betonu komórkowego (ABK), podzielonych na cztery dwuelementowe serie. W pierwszej serii oznaczonej jako HOS-AAC zbadano 4 elementy (modele referencyjne) pozbawione otworów. W pozostałych trzech seriach ścian zróżnicowano kształt otworów oznaczonych umownie jako A, B i C. Scharakteryzowano zmianę morfologii zarysowań oraz mechanizm zniszczenia. W kolejnym artykule przedstawione zostaną pozostałe efekty istotne z praktycznego punktu widzenia.
EN
This paper demonstrates the author's own results from tests performed on ten masonry units made of autoclaved aerated concrete. The tests were performed in four series of two elements. The first series denoted as HOS-AAC included four elements (the reference elements) without openings. In remaining three series, we used walls with different opening shapes denoted by convention as A, B and C. The failure mechanism and changes in cracking morphology were described. The next part will present the remaining results that are relevant from the practical point of view.
10
Content available remote Tests of joints in AAC masonry walls
EN
The paper presents the results of the Authors’ tests on the joints in AAC masonry walls. The shape of the tested element and the test stand were fitted innovatively based on the Authors’ own experience as well as on the literature overview and numerical analysis. Cracking morphology and mode of failure were investigated. The relationship between the load and displacement for different types of joins was compared. The obtained results were also compared to the results obtained on the reference model, which was a model with a traditional masonry bond. In the remaining testing elements, the connection was realized with the use of steel connectors. Various mechanisms of cracking and failure have been observed as well as the behaviour and load-bearing capacity of joints were different. The obtained results encourage to further analyses focused on detailing the joints and application of new methods in the construction of the joints.
11
Content available remote Połączenia ścian murowych, podstawy teoretyczne
PL
Podczas projektowania zakłada się przestrzenną współpracę stropów oraz ścian, która wpływa na warunki stateczności oraz sztywności konstrukcji budynku. Połączenia ścian rozpatruje się nie tylko w aspekcie konstrukcyjnym, ale również pod kątem izolacyjności termicznej i akustycznej, które najczęściej absorbują najwięcej uwagi. Normy projektowania konstrukcji murowych nakazują jednak sprawdzenie nośności połączenia ścian, nie podając żadnych algorytmów obliczeniowych, a nawet procedur badawczych. Taki stan rzeczy wynika z tradycyjnego podejścia, że spełnienie warunków konstrukcyjnych zapewnia spełnienie warunków ULS. Przy stosowaniu nowoczesnych konstrukcji ścian oraz łączników sprawdzenie nośności połączenia ścian może okazać się niewystarczające, a nawet niebezpieczne. Artykuł rozpoczyna cykl publikacji poświęconych tematyce połączeń ścian, starając się wypełnić obserwowaną lukę w aktualnym stanie wiedzy. Na wstępie zaprezentowane zostaną ustalenia normowe i podstawowe poglądy w tej dziedzinie. W kolejnych publikacjach omówione zostaną wyniki badań własnych połączeń ścian murowych z autoklawizowanego betonu komórkowego (ABK) i numeryczne modele MES.
EN
In the design process spatial co-operation of floors and walls is assumed which has an influence on the stability and stiffness of the building’s structure. Wall joints are investigated not only in the structural aspect but also in the view of their thermal and acoustic insulation, which usually focuses most of the attention. Design standards for masonry structures demand, however, that load-bearing capacity of walls joints is controlled but without providing any calculation algorithms, let alone testing procedures. This results from the commonly used assumption that conditions of structural safety are fulfilled when ULS conditions are satisfied. When modern structures of masonry walls and connectors are used, control of the load-bearing capacity of the wall joints can be insufficient or even dangerous. This paper begins a series of publications dedicated to the topic of wall joints, aiming at filling up a void in the current state of the art. This introduction presents standard recommendations and basic approaches to the matter. The following publications will discuss the original test results of autoclaved aerated concrete (AAC) masonry walls joints and numerical simulations.
12
Content available remote Badanie połączeń ścian murowych
PL
W artykule zostały przedstawione wyniki badań własnych połączeń ścian wykonanych z autoklawizowanego betonu komórkowego. Przeanalizowano morfologię zarysowań i mechanizm zniszczenia, porównano zależność obciążenie - przemieszczenie różnych typów połączeń. Uzyskane wyniki odniesiono do rezultatów otrzymanych z modelu referencyjnego z klasycznym wiązaniem murarskim. W pozostałych modelach badawczych połączenie zostało ukształtowane przy użyciu najpowszechniej stosowanych w Polsce łączników stalowych w postaci: kątowników oraz blaszek perforowanych. Wykazano różny mechanizm zarysowania i zniszczenia oraz wyraźne różnice nośności każdego typu połączenia.
EN
The paper presents original results of the tests performed on the joints of the walls made of AAC blocks. The analysis covered morphology of cracking and failure mechanism, as well as comparison of stress - strain relationship of different types of joints. The obtained results were related to the results of the reference model which was the model with classical masonry joint. In the remaining testing models the joint was made with the use of the most commonly used steel connectors in Poland applied in these joints: angle profiles and punched flat profiles. It has been shown that the joints differ in the cracking pattern and failure mechanism as well as in the load-bearing capacity.
13
Content available remote Modele nośności granicznej ścian ścinanych – weryfikacja eksperymentalna
PL
W artykule przedstawiono porównanie wyników obliczeń kratownicowych modeli prętowych, stosowanych w niezbrojonych ścianach ścinanych poziomo, z wynikami badań przeprowadzonych w Holandii, Portugalii i Szwajcarii. Ponadto wyniki obliczeń porównałem z badaniami własnymi ścian ścinanych poziomo wzniesionych z cegły pełnej, elementów silikatowych i z autoklawizowanego betonu komórkowego. Ze względu na specyfikę obciążenia i schemat statyczny dokonano stosownej modyfikacji modelu.
EN
The article presents a comparison of the results of calculations made by the authors of equilibrium models with the results of research carried out in the Netherlands, Portugal and Switzerland. In addition, the author compared the results of the calculation of own research made in Poland horizontal shear walls made of clay bricks, calcium silicate and autoclaved aerated concrete units. Due to the nature of the load and static scheme have been used to modify the model.
14
Content available remote Modele nośności granicznej ścian ścinanych – podstawy teoretyczne
PL
Oprócz modeli tarczowych, które opracowano na podstawie obserwacji mechanizmu zniszczenia, do bezpiecznego obliczania nośności ścian stosowane są modele prętowe. W zależności od warunków podparcia i obciążenia ściany wyróżnić można proste modele prętowe, kiedy do ściany przyłożone jest obciążenie skupione (modele typu I) lub modele z rozmytymi prętami (modele typu II), gdy ściany obciążone są równomiernie na krawędzi. Podstawową zasadą wykorzystywaną przy budowie tego typu modeli jest ograniczenie do minimum liczby prętów, przy jednoczesnym zachowaniu geometrycznej niezmienności modelu. Artykuł jest drugą częścią przeglądu metod obliczeń nośności na ścinanie niezbrojonych ścian murowanych. Pierwsza część została opublikowana w „Materiałach Budowlanych” nr 4/2015 [3]. W kolejnej części zaprezentowana zostanie eksperymentalna weryfikacja modeli prętowych.
EN
In addition to the panel model, which was developed based on observations of the destruction mechanism to secure cracks resistance calculator walls struts models are used. Depending on the support and the loads the wall can be identified simple models struts wall when the concentrated load is applied (Model Type I) or rods smeared models (models of type II), when the walls are loaded evenly on the edge. The basic principle used in the construction of such models to minimize the number of rods, while retaining the model geometric invariance. The article is the second part of the review of the methods of calculation shear capacity of unreinforced masonry walls. The first part of the reader can be found in the „Materiały Budowlane” No. 4/2015 [3]. The next part will be presented experimental verification of simple equilibrium models.
15
Content available remote Tarczowe modele zarysowania i zniszczenia ścian ścinanych
PL
Artykuł rozpoczyna cykl kilku publikacji dotyczących zagadnień związanych ze ścinaniem w konstrukcjach murowych. Omówiono kompleksowy tarczowy model zniszczenia ściany scharakteryzowany przez zróżnicowane mechanizmy zniszczenia ściany: ściskanie w narożnych strefach muru, ukośne rozciąganie, ścinanie zaprawy w spoinach wspornych. Atutem tarczowych modeli jest przewidywanie mechanizmu zniszczenia ściany umożliwiające skuteczne zastosowanie wzmocnień lub zmiany schematu statycznego.
EN
Article begins a series of several publications on issues related to the shear in masonry structures. As a preliminary discussed complex panel model characterized by the destruction of the walls of different mechanisms to destroy the wall: rocking, diagonal cracking, sliding shear. The advantage of panel models is the ability to predict the destruction mechanism for the effective use of wall reinforcements or change the static scheme.
EN
The paper presents the basic achievements of many years of scientific work of Professor Cholewicki on: load bearing capacity and deformability of the vertical joints in large panel buildings, the calculation methodology of shear walls, the impact of floor integrating character in the horizontal transfer interactions, the efficiency of the shear connections in composite precast concrete structures, design concepts skeletal precast RC structures in accidental situation (progressive collapse) and the principles of design and diagnosis of buildings subjected to paraseismic soil tremors in mining areas.
PL
W pracy przedstawiono podstawowe osiągnięcia wieloletniej pracy naukowej Profesora Cholewickiego w zakresie: nośności i odkształcalności złączy pionowych w budynkach wielkopłytowych, metodyki obliczeniowej ścian usztywniających, wpływu integrującego charakteru tarczy stropowej w przenoszeniu oddziaływań poziomych, efektywności zespolenia w prefabrykowanych konstrukcjach typu beton-beton, koncepcji projektowania szkieletowych konstrukcji żelbetowych z uwagi na możliwość wystąpienia sytuacji wyjątkowej (katastrofy postępującej) oraz zasad projektowania i diagnozowania budynków poddanych oddziaływaniom wstrząsów parasejsmicznych na terenach górniczych.
17
Content available remote Free vibration analysis of shear wall structures with stiffening beams
EN
The paper presents the free vibration analysis of non-planar asymmetric shear wall structures with connecting and stiffening beams. The stiff beams incorporated at various levels of coupled shear walls improve the stiffness of the structural system of the building. The analysis is based on a variant of the continuous connection method for three-dimensional shear wall structures having stepwise changes in cross-section. The mass matrix including flexural and torsional inertia is generated. As a result of solving eigenproblem, which corresponds to free vibration equation, natural frequencies and mode shapes of vibration have been received. The results obtained by this method have been compared with those available in literature and a satisfactory match has been observed.
18
Content available remote Ściany murowe poddane ścinaniu
19
Content available remote Effective algorithm of flexibility matrix computation for shear wall tall building
EN
The dynamic analysis of three-dimensional coupled shear wall structures in tall buildings has been studied. A hybrid approach, based on the analysis of an equivalent continuous medium and a discrete lumped mass system has been used. The algorithm of flexibility matrix computation is presented in this approach. It has been observed that the results of this method are a good match with those obtained using the finite element method.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.